TRAN SMISS IO N LI NE

Character ist ic s
• It is a metallic conductor system used to transfer
electrical energy from one point to another using
electrical current flow.

• Nowadays, the transmission line is made of


parallel-conductor (copper wire) and coaxial
cable.

• It consists of 2-wire line since transmission line


for transverse electromagnetic TEM wave
propagation always have 2 conductors.

• The characteristic of Transmission Line are


determined by its electrical properties :
Conductivity & Insulator Dielectric Constant

September 18, 2009 FKEE Norizam 2


Types of Transmission Lines

• Open-Wire
• Twin-Lead
• Twisted-Pair
• Coaxial

September 18, 2009 FKEE Norizam 3


Metallic transmission lines

Open-wire Twin lead

September 18, 2009 FKEE Norizam 4


Metallic transmission lines
Unshielded twisted-pair

September 18, 2009 FKEE Norizam 5


Metallic transmission lines

Coaxial cable

September 18, 2009 FKEE Norizam 6


Metallic transmission lines
Differential, or balanced, transmission system

Balanced lines have equal impedances from the two


conductors to ground
Twisted-pair and parallel lines are usually balanced

September 18, 2009 FKEE Norizam 7


Ideal Transmission Line
• No losses
– conductors have zero resistance
– dielectric has zero conductance
– possible only with superconductors
– approximated by a short line

• No capacitance or inductance
– possible with a real line only at dc
– with low frequencies and short lines this can be
approximated

September 18, 2009 FKEE Norizam 8


 The electrical properties determine the PRIMARY electrical
constant:
 Series Resistance, R
 Series Inductance, L
 Shunt Capacitance, C
 Shunt Conductance, G

 The combined above parameter is called LUMPED


PARAMETERS.

 Refer to Figure 12-14 & 12-15 in the textbook for the two-wire
parallel transmission line and single section transmission
line.

 The transmission line characteristic is called SECONDARY


CONSTANT.

 The secondary constants are:


1. Characteristic Impedance
2. Propagation constant
September 18, 2009 FKEE Norizam 9
Two-wire parallel transmission line
electrical equivalent circuit

September 18, 2009 FKEE Norizam 10


Char acteri stic Impedance
The characteristic Impedance, Zo is defined as :
A transmission line must be terminated at purely
resistive load for maximum power transfer.

 Zo = ( R + jwL) / (G + jwC )
 Zo = R/G for Low Frequencies
 Zo = L/C for high Frequencies

The conductance between 2 wires are determined


by the shunt leakage resistance, Rs

The load impedance, ZL must match with


characteristic impedance, ZO

September 18, 2009 FKEE Norizam 11


 Refer to figure 12-16 for Characteristic impedance
of a transmission line of infinite section.

 The characteristic impedance can be calculated


by using Ohm’s Law:
Zo = Eo / Io

where Eo is source voltage and Io is transmission line


current

 The characteristic impedance also can be


calculated by its physical dimension:

September 18, 2009 FKEE Norizam 12


Any transmission line that is terminated is a
purely resistive Load in infinite line:

 Zi = Zo

 No Reflected Wave

 V & I in phase

 Maximum Power Transfer from source to


load

September 18, 2009 FKEE Norizam 13


Propagation C onsta nt
 Propagation Constant is used to express the
attenuation (signal loss) and the phase shift per
unit length of a transmission line.

 It is defined as :
γ = α+ jβ

γ = ( R + jwL)(G + jwC )

Where γ = propagation constant (unitless)


α = attenuation coefficient (nepers per unit
length)
β = phase shift coefficient (radians per unit
length)
September 18, 2009 FKEE Norizam 14
For an ideal line R and G are zero

  j LC purely imaginary and no attenuation


 0
   LC

September 18, 2009 FKEE Norizam 15


Transmission Lines Losses
• Conductor Losses
•Increases with frequency due
to skin effect
• Dielectric Heating Losses
•Also increases with frequency
• Radiation Losses
• Not significant with good
quality coax properly installed
• Can be a problem with open-
wire cable
• Coupling Losses
• Corona

Skin effect
September 18, 2009 FKEE Norizam 16
Transmission Lines Losses

September 18, 2009 FKEE Norizam 17