J.

Marschinke
Production Leon, Leon plus, etc.
Central office Bad Ems
Anesthesia Workstation
for Pediatric and Adult care
Ventilator is working with an pneumatic drive
and hanging bellows
Inhalant anesthetic in a rebreathing system
Inhalant anesthetic in a semi-closed system
Low flow range
Minimal flow range
Non-rebreathing system
Bain
Magill
Jackson Rees
Kuhn

Ventilation Modes

(S) IMV (Synchronized)
Intermittend Mandatory Ventilation

(S) PCV (Synchronized)
Pressure Controlled Ventilation

PSV Pressure Supported
Ventilation

Man. Manual Ventilation

Spont. Spontaneous Ventilation
System Description
Patientmodul


Fresh gas decoupled
Tempered:
preventing condensation
warming respiratory gas
APL decoupled during controlled
ventilation
Patientmodul


Switch to semi-open system
Inspiratory and expiratory flow
sensors
Absorber can be exchanged during
operation
Can be fully sterilized
Compliance compensated
Features
15 TFT color display
Operation via touchscreen and/or control knob
Electronic fresh gas blender
One-hour rechargeable battery buffering
Interface to control monitors of other
manufacturers
Ethernet interface
Gas monitor (choose between mainstream and
sidestream) with automatic detection of
anesthetic gas and anesthetic gas mixture
Features
Receptacle for two anesthetic vaporizers
Undercarriage with 4 antistatic rollers, all with
brakes
4 Drawers
1 cupboard reserve bottle connections for O and
NO
Pull out writing surface, DIN A4
Rails on right and left to fit support arms and
other accessories
O

Emergency Control
O

Emergency control
Settings between 0
15 l/min.
Use for fail of fresh
gas blender
Use for quick start
Use for device is
turned off
Gas Management
Sidestream Monitor
with real time
measurement and real
time graphs
Paramagnetical O


measurement
Different water trap for
exactly measures in
patient category child
Optional: Main stream
monitor
Configuration of the options panel
Solution for half open breathing
system (Kuhn, Jackson Rees,
Magill, Bain)
Configuration of the options panel
Solution external O

outlet
Pressure gauges and control
elements

O

flush
Turn
switch
for
vacuum
dosing
Vacuum
dosing
Vacuum
pressure
O

bottle
pressure
N

O
bottle
pressure
New Ventilation Mode
PSV Pressure Supported Ventilation

Psv provides pressure support during insufficient
spontaneous breathing.
If the Leon plus is not triggered by the patient after
the adjustable apnoe time, the Leon plus initiates
inspiration on ist own.
In addition, you can use a button to start a manual
breath, not activated by the patient.







Real time graphs and
complete Measurement




Air or NO as carrier gas
Set percent oxygen to total
fresh gas flow
Set total fresh gas flow
Setting range
200 ml / min. 18 l / min.
Ensure O concentration in O /
NO mixture of 25 %
Option: 10 l Reserve gas bottle
with the pressures on the
display
Fresh gas control
Real time graphs
Values as real time graphs
Airway pressure
Flow
Volume
CO

(% or mmHg)
O

N

O
Halothane
Enflurane
Isoflurane
Sevoflurane
Desflurane


Values displayed in
numerical form
Real time
measurement:
Minute volume, tidal
volume, Peak /
Plateau / Mean
pressure, PEEP,
Frequency
Calculated values
like MAC,
Compliance, C20/C,
Resistance
Numerical display on two pages


Loops

One Loop at a time can be displayed in full screen

Loops
Loop window
Three loops can be
displayed in the Loops
window
Volume over pressure
Flow over pressure
Flow over volume

One Loop at a time can be
displayed in full screen




Alarm limits for monitoring (adjustable)
Function of Autoset
Alarms with three different priorities
(high, medium, informal)
Complete history of alarms in the Log
Adjustable loudness of alarm tone
Alarm Limits


Wall mount
Different Solutions
Ceiling swingarm mount


More
Solutions