Professional Documents
Culture Documents
Centrifugal Pump Performance Experiment: Presented By: Steven King
Centrifugal Pump Performance Experiment: Presented By: Steven King
Performance Experiment
Presented by: Steven King
Overview of Presentation
Objectives
Methodology
and Background
Experimental Setup
Discussion of Results
Conclusions and Recommendations
Objectives
Become
Key Equations
B
(1) Cd 0.907 6.53
ReD
(2)
R ED
Vt 2 D1
(3)
(4)
Vt C d
Q C d AtVt
(5)
P2 P1 V2 2 V12
Hp
Z 2 Z1
2g
g
1
4
W pump QP2 P1
(7)
pump
QP2 P1
Affinity Laws
Q 2 Q1
N2
N1
N2
Hp2 Hp1
N1
N2
P2 P1
N1
Experimental Setup
Overall System Schematic
= 1.5 in
Results
wQ = 38.0%
w = 39.7%
%
Difference
5.61E-03
5.30E-03
5.55
P (W)
435.8
470.8
7.43
Hp (m)
7.92
9.06
12.58
7.49E-03
6.96E-03
7.12
P (W)
906.1
1066.4
15.03
Hp (m)
12.33
15.6
20.96
Q (m3/s)
1530 RPM
Calculated
Using Affinity
Laws
Results Cont.
Pump Head vs. Flow Rate
20
18
2
16
14
12
y = -109848x2 + 75.198x + 14.49
R2 = 0.9972
10
8
2
900.2 RPM
992.8 RPM
1165 RPM
1352 RPM
1530 RPM
0
1.5E-03
2.5E-03
3.5E-03
4.5E-03
5.5E-03
6.5E-03
7.5E-03
8.5E-03
Results Cont.
Pump Efficiency vs. Flow Rate
0.8
y = -9353.1x2 + 165.91x - 0.0087
R2 = 0.9985
0.7
0.6
Pump Efficiency
0.5
y = -9886.8x2 + 151.87x - 0.0003
R2 = 0.9989
0.4
y = -15468x2 + 165.33x + 0.0014
R2 = 0.9976
0.3
0.2
1165 RPM
1352 RPM
1530 RPM
0.1
0.0
0.0E+00
1.0E-03
2.0E-03
3.0E-03
4.0E-03
5.0E-03
6.0E-03
7.0E-03
8.0E-03
Results Cont.
Pump Efficiency vs. Pump Power to Fluid
0.8
0.7
0.6
Pump Efficiency
0.5
0.4
0.3
0.2
900.2 RPM
992.8 RPM
1165 RPM
0.1
1352 RPM
1530 RPM
0.0
0
100
200
300
400
500
600
700
800
900
1000
Results Cont.
Pump Power to Fluid vs. Flow Rate
1000
900
800
700
600
500
400
300
900.2 RPM
200
100
992.8 RPM
1165 RPM
1352 RPM
1530 RPM
0
0.0E+00
1.0E-03
2.0E-03
3.0E-03
4.0E-03
5.0E-03
6.0E-03
7.0E-03
8.0E-03