Diagnostics Certification Training

SPM, Vibration Measurement,


Datalogging with IR30

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

What is an IR30?

Hand held - predictive maintenance tool

Shock Pulse Bearing Monitoring Device


(IR30 Sentinel)

Vibration Severity Meter


(IR30 Logger)

Condition Monitoring Instrument

Data logger

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

Que es una Herramienta IR30?

Herramienta Manual de Mantenimiento


Predictivo

Dispositivo de medicion de pulsos de choque


en rodamientos

(IR30 Sentinel)

Medidor de Vibracion
(IR30 Logger)

Instrumento de Monitoreo

Dispositivo de Almacenamiento de Datos

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30 Logger- Vibration Measurement with


Accelerometer

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30 Medicion de Vibracion con


Acelerometro

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30 Data Logger Kit CCN 39263009


Includes:
I-R 30 Instrument
Condmaster Pro Software
Instruction Manual
PC cables & hardware key
Vibration probes
Batteries
Carrying case

CCN: 39263009

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30 Data Logger Kit CCN 39263009


Includes:
I-R 30 Instrument
Condmaster Pro Software
Instruction Manual
PC cables & hardware key
Vibration probes
Batteries
Carrying case

CCN: 39263009

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30 Logger, Sentinel & Compact

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30

IR30 Logger - features

Vibration readings with accelerometer


SPM with manual probe
PC communication

Preloads machine data prior to visit


and produces trend analysis.
Have route capability
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

Diagnostics Certification Training

IR30 Logger - features


Lectura de Vibraciones con Acelermetro
Lectura de Pulsos de Choque en forma
manual
Comunicacion con PC

Precarga de Parametros de cada Maquina


segun programa de visitas.
Have route capability
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30-Sentinel
IR30 Sentinel Takes SPM readings and it
does not have route capability.
Readings are taken and then documented.

Data is then transferred to either Condmaster


Pro or Excel trending files manually.
Sentinel may be upgraded to logger for fee.

CCN 38332284
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30-Sentinel
IR30 Sentinel toma lecturas de Pulsos .
Lectura y almacenamiento en un documento.
Data es transferida del Condmaster Pro a
documento Excel manualmente.

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30

IR30 Compact
IR30 Compact uses same technology as sentinel
to take SPM readings
Compact does not have Vibration capability.
Compact can store ten readings

Can take set of readings on one or two machines and then record
data on inspection sheets

Compact has Infrared temperature reading


Compact has Electronic Stethoscope capability with
standard set of headphones.
Compact significantly less expensive than Sentinel.

Compact is not intended as a replacement for


Sentinel and logger but as another tool to
accomplish Shock pulse monitoring and trending.
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

Diagnostics Certification Training

IR30

IR30 Compact
IR30 utiliza la misma tecnologia que el sentinel
para tomar lecturas de Pulso de Choque
Compact does not have Vibration capability.
Compact can store ten readings

Can take set of readings on one or two machines and then record
data on inspection sheets

Compact has Infrared temperature reading


Compact has Electronic Stethoscope capability with
standard set of headphones.
Compact significantly less expensive than Sentinel.

Compact is not intended as a replacement for


Sentinel and logger but as another tool to
accomplish Shock pulse monitoring and trending.
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

Diagnostics Certification Training

Evaluation in green,
yellow and red

SPM transducer,
dBm/dBc
Display with backlight

Five buttons

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

Headphone connection
for listening to
shock pulses or
machinery noise

Blue LED
indicating measurement

LEMO connector for


external SPM transducers

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR 30 - Two Different Types of Measurements

(IR30 Logger)

(IR30 Sentinel)
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR 30 - Shock Pulse Method


Piezo-electric transducer
approx. 30kHz natural frequency

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR30

SPM Shock Pulses


Pressure waves, generated by rolling
elements and the raceway.
Measured by transducer which amplifies the
shock signal and filters out machine
vibration.
Pattern consists of a rapid sequence of
strong and weak pulses
dBc decibel carpet - the large number of
relatively weak shock pulses
dBm ( decibel max) - few strong pulses in
the pattern
IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

Diagnostics Certification Training

Normalized & Absolute readings


dBi =initial value of a bearing
(Function of Rotor Diameter & Rotor
Speed). If dBi is not known, use
25 as default to Oil Injected
units and 35 to Oil Free units.
dBc=Carpet value (weak pulses)
dBm=Maximum value (strong
pulses)
dBn=Unit for normalized shock
level
dBsv=Unit for absolute shock
level

dB=20Lg10 Vin
Vcc

Lg100,1=-1; Lg101=0; Lg1010=1; Lg10100=2;


IR Global Service Education Team
Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30

Diagnostics Certification Training

IR 30 - Shock Pulse Method

IR Global Service Education Team


Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

IR30