This document provides a 17-step guide for installing and using the Actix software:
1. Install Actix and copy necessary files to specified folders without running the software.
2. Run edgespro11.exe and generate a license code. Copy the code but do not close the application.
3. Run SENTEMUL2007.exe, paste the license code, start the emulator service, and load a dongle dump file to emulate a dongle. Copy the licensed dongle code.
4. Paste the dongle code into edgespro11.exe and install a Windows update to complete the installation.
This document provides a 17-step guide for installing and using the Actix software:
1. Install Actix and copy necessary files to specified folders without running the software.
2. Run edgespro11.exe and generate a license code. Copy the code but do not close the application.
3. Run SENTEMUL2007.exe, paste the license code, start the emulator service, and load a dongle dump file to emulate a dongle. Copy the licensed dongle code.
4. Paste the dongle code into edgespro11.exe and install a Windows update to complete the installation.
This document provides a 17-step guide for installing and using the Actix software:
1. Install Actix and copy necessary files to specified folders without running the software.
2. Run edgespro11.exe and generate a license code. Copy the code but do not close the application.
3. Run SENTEMUL2007.exe, paste the license code, start the emulator service, and load a dongle dump file to emulate a dongle. Copy the licensed dongle code.
4. Paste the dongle code into edgespro11.exe and install a Windows update to complete the installation.
This document provides a 17-step guide for installing and using the Actix software:
1. Install Actix and copy necessary files to specified folders without running the software.
2. Run edgespro11.exe and generate a license code. Copy the code but do not close the application.
3. Run SENTEMUL2007.exe, paste the license code, start the emulator service, and load a dongle dump file to emulate a dongle. Copy the licensed dongle code.
4. Paste the dongle code into edgespro11.exe and install a Windows update to complete the installation.
2. Install Software with default settings. Don't run software after installation. 3. Copy "lservrc" and "Analyzer.exe" into following folder: C:\Program Files\Actix\Analyzer\Bin\ 4. Copy "lservrc" into following folder: C:\Documents and Settings\All Users\Application Data\Actix\Analyzer\Bin 5. run "edgespro11.exe"; In "edgespro11.exe": 5.1. go to tab "keygen" 5.2. In "Dongle Type" choose "Sentinel" 5.3. In "License Validity" set "Starts at" and "ends at" dates; 5.4. Click "Generate"; Copy the Code shown in the lower part of the window. 5.5. don't close this application now
Installation
6. run "SENTEMUL2007.exe"; In "SENTEMUL2007.exe":
6.1. go to tab "Driver"; Click "Install Driver" button 6.2. go to tab Emulator"; Paste the code you have copied in step 5.4 in the "License" box 6.3. Click "Start Service" 6.4. go to tab "Dongles"; Click the button "Load Dump" and choose the file "actix_full.dng" 6.5. go to tab " Emulator "; you see a code in the box under title "Licensed Dongles"; Copy that 7. Go to "edgespro11.exe" and go to tab "Keygen" 7.1. Paste the code you have copied in the Left & down box (left-down) 8. Install WindowsXP-Windows2000-Script56-KB917344-x86-enu 9. Everything is finished and now you can run ACTIX program from it's shortcut on desktop
Start Application
Binning
Binning is a procedure in which several point/plot are grouped into a function
(distance, location or time) unit Binning Setting (Location 5x5m) Tools>Preferences>Binning 5
Load Logfile
Start to post processing logfile
File>Open Logfile 6
Mobile Station Configuration
Logfile 0208_25.log Logfile 0207_17.log
A Logfile consist of information from 3 Mobile Station:
MS1 for Idle Mode MS2 for Dedicated Mode MS3 for GPRS Data 7
Superstream
Superstream is process to merge several logfile
Tools>Create Superstream
Information Collect (MS1-Idle)
Open Superstream, MS1
From MS1-Idle, we will get information of :
Serving Cell Parameter ServCI and
Downlink Measurement ServRxLevIdle 9
Information Collect (MS2-Dedicated)
Open Superstream, MS2
From MS2-Dedicated, we will get information of : Serving Cell Parameter ServCI and Downlink Measurement ServRxQualSub Event Data GSM_Call_Setup_Time 10
Information Collect (MS3-GPRS Data)
Open Superstream, MS3
From MS3-GPRS, we will get information of : Application Measurement App_Throughput_DL Application Measurement App_Throughput_UL 11
Plot to MapInfo
12
Save Workbook
Save parameter export (for example:ServCI-Idle) as workbook (.xls) to open