RS CONSULTANCY

Automation and Control System Consultant


Corporate Office : Plot-118 , Block BB , 1st Floor
1951 Rajdanga Main Road , Kolkata 700107
Besides Siemens
Ph: 033-4063-0276 , +91-9330970511
Regd. Office :

Vill + Post : Chakpara , Liluah , Howrah 711204


West Bengal.

Raipur Office:

Sector 4, Block 65 , Vinayak Garden , Sivananda Nagar


Srinagar , Raipur , Ph: +91-8959257182

Website : www.rsconindia.com
E mail : contact@rsconindia.com
pritam@rsconindia.com

Our Clients in Power and Steel Sector

VECC

Our Achievements

Thanks to the valued support that we received


from Domain Experts and our valued customers,
we have now developed expertise in some of the
Niche Domains as under.
1.Energy Monitoring & Reporting System.
2.Power Factor Control System.
3.Load Shading & Power Management System.
4.Transformer Monitoring & Control System.
5.RTUs.
6.Furnace Monitoring and Control System.
7.Batching system for furnaces.
8.Bag Filter Monitoring & control system.
9.Production Management System
10.Plant data acquisition and interface with ERP.
11.DCS Data Centralization and Reporting.
12. Modbus Gateway.
13.Hand Shaking with 3rd Party System.

Integration House

Development
Center

SCADA Development

RTU INSTALLATION

Energy Monitoring SCADA

Energy Monitoring System

RTUs
The solution needed to monitor single and three phase RMS power measurements at a number of
remote sites .The RTU capture power data from generation and export units and send same to Grid
through lease line modem over IEC protocol .

Key Capabilities
DNP, IEC 60870-101, 104, Modbus Interfaces
Client Data Mapping to for electrical substation monitoring
Compliance to Electric Power Standards for EMC and Voltage Isolation
Database sizes up to 20,000 distributed points
Distributed Architecture

Power data
(DI & AI) or
RS-485
RTU
iec-101

Modem

Modem

GRID
SCADA

RTU

Power Factor Control System.


Objective:
1. High Speed data Acquisition Like MVA,PF
2. Pulse output to existing MVAR Control Device for
the TG generated power based on the many
criteria logic.
3. Finally try to balance pf

PF Transducer
MVA Transducer

Controlle
r

MVA
Panel

Product Used:
ADAM-5510KW/TCP
Feedback
System working more than two years satisfactory

Power Factor Control System

Power Shading System.


Objective:
1. High Speed data Acquisition like MW ,MVA from
different feeders , TG etc.
2. High Speed data Acquisition of Turbine Parameter
like Frequencies etc.
3. Based on the criteria , power shaded as per
availability.
MW
MW
MW
MW
MW

TG
MW
SID
Furnaces
And
FA

Import /
Export MW

Breaker Status
for grid failure

Controlle
r
Product Used:
ADAM-5510KW/TCP

Feedback
System working more than two years satisfactory

Plant data acquisition


PLC A

PLC B

DCS

DCS

Energy Meter

PLC C

Plant Network

DeSERV
ER

Corporate Network

Web Access SCADA

ERP

HMI

Reporting System

Furnace Control and Monitoring System

Furnace Control and Monitoring System

Furnace Monitoring and Control System


Project Outline
Furnace Monitoring
Furnace Control
Prevent safety and
interlock
Alarm generation
Monitor through SCADA.
Furnace Control Systems
Management

System Description
ADAM-5000/TCP responsible for controlling Tap Positioning, Electrode
and other equipment and also carries out communications and data
process systems.
ADAM-5017 for the data acquisition of Voltage, Current.
ADAM-5051D takes charge of the data acquisition of pump status, water
pump status, Transformer winding temperature, Transformer oil
temperature.
ADAM-5056D is responsible for Alarm, controlling current.

Advantechs ADAM-5000 series control system carries out the mission of


monitoring & control the furnace system

SCADA

PLC Panel

ADAM Controller

Pollution Monitoring System

ONLINE TRANSFORMER CONDITION MONITORING


SYSTEM
Under this implementation, R S Consultancys solutions have more than met
the requirements of this prestigious Transformer Monitoring and Control
System
Project Outline

Features

System design and engineering

Average Oil Temperature

Selection of optimum components

Top Oil Level

Hardware installation

Winding Temperature

Start-up and commissioning

Ambient Temperature

Communication system installation

Power Factor

System and software integration

Transformer Voltage and

Remote monitoring and diagnostics

(optional)

Current
Cooling Fan and Pump

Status
Tap Changer Information

SCADA

PLC Panel

atching system

SCADA

atching system

SCADA

atching system

SCADA

Bag Filter System: Pollution control


system

Bag Filter System: Pollution control


system

Production Management System

Production Management System

Production Management System


01-01-2014 (F_Mn 75%)
Parrticulars

Landead Price
Qty

No. of
Charges

Extra Feeding

900

41.5

-3

37.347

647784

Total Conumption Total Value

BHP Bulletin 48-50%

17345

Oswal Lumps 42-46%

15995

MV Pyxis 42-44%

15625

600

41.5

-1499

23.401

365641

MV Glowria Fines 36-38%

10995

450

41.5

18.676

205343

MV Interprid Lumps 36-38%

10836

270

41.5

11.211

121482

Radhika Lumps 24-26%

4220

150

41.5

1896

8.121

34271

Mill Scale (GPIL)

6525

Total

98.756

Steam Coal (GPIL)

6219

90

41.5

-102

3.633

22594

Maa Lilori Coke (Pearl Coke)

13670

480

41.5

599

20.519

280495

Total

24.152

Quartz

725

41.5

Dolomite

1563

40

41.5

1.66

2595

Total

1680203