Professional Documents
Culture Documents
ASCV
ASCV
ASCV
General
ISO 9001:2008
ISO 9001:2008
ATC
ASCV
MODEMS
ASCV
MODEMS
To West ASCV
DMS
FSFB net
To East ASCV
UCS
SSW
SLE N
SLE R
ULE
SDM
ULE
UVIO
UVPS
UVIO
CVCM
Cables
frame
PDC
ASCV
SAT
Relay
Actuators
Electronic
Actuators
ISO 9001:2008
SLE STATUS
(Subsystem for Logic Elaboration)
ASCV contain two SLE, one is named SLE/N (Normal) ,the other
one named SLE/R (Reserve). During operation both SLE can in one
of the following status
In Service : The SLE which is currently working
Standby : The SLE which is not in service but which can enter to
service when request
Non active : SLE may be off , fault, or in maintenance or
momentarily disturbed
Inside SLE there are two or more units:
1
ULE (Unit for Logic & Elaboration )
1 to 3 UVIO (Unit for Vital Input Output)
ISO 9001:2008
MAIN
RECHECK
VCOM
NVIO
EVPD
Main Module
ECPU3 + ESYMOD
EIOINT
ISO 9001:2008
ISO 9001:2008
Main Module:
ECPU3 + ESYMOD card: controls vital input reading using the EIOINT card; performs all information
collection and distribution operations from and to the other functioning modules, processes the Boolean
equations, controls non-vital synchronisation with the other ULE.
EIOINT card: implements hardware mechanisms used to securely check its own identity and correct
access to vital input cards. Inserts and reads codewords on vital input modules, converts signal electric
levels ensuring a reliable connection from a distance with the EIOBUF card, that is to say the UVIO unit.
ISO 9001:2008
Recheck Module
ECPU2
EIOINT.
ISO 9001:2008
Recheck module
Boards belonging to the Recheck module are
Identification
always placed immediately to the right of the
main module.
ISO 9001:2008
Recheck Module
In the RCHK module, the functions are divided amongst the cards as follows:
ECPU2 card: manages codeword reading and writing operations on the EIOINT card for
controlling vital outputs and SLE subsystem ON switch, for vital output state readouts and
reading SLE identification vital information. Checks that the command received matches
vital output state.
EIOINT card: implements hardware mechanisms used to securely check its own identity
and correct access to vital output cards. Inserts and reads codewords on vital output
modules, converts signal electric levels ensuring a reliable connection from a distance with
the EIOBUF card, that is to say the UVIO rack containing the vital outputs.
ISO 9001:2008
EHICOM N/R,
EHICOM ASCV NET cards
Other EHICOM NET cards for other vital nets
ISO 9001:2008
In the VCOM module, the functions are divided amongst the cards as follows:
EHICOM NET 1 card: this card controls communications to the 1st FSFB network using the optic
modems contained in the UCS unit. The card controls and checks communication up to the excluded
application level.
EHICOM NET 2 card: carries out the same functions as the EHICOM NET 1 card and is connected to
the 2nd FSFB network.
ISO 9001:2008
Vital
Communication
Module
ISO 9001:2008
EVPD module
ISO 9001:2008
ISO 9001:2008
VCOM
SLE
EHICOM
NET
ULE
EHICOM
ATC
EHICOM
N/R
SYSTEM BUS
RCHK
MAIN
ECPU3
iSBX
ESYMOD
ELOB
EIOINT EIOINT
M1
M2
ECPU2
ELOB
EIOINT
EVPD
EVPD
E3
ISO 9001:2008
ECPU1
EHICOM Non Vital NET
E32INP
E32OUT.
ISO 9001:2008
ISO 9001:2008
ISO 9001:2008
VINP
VOUT
ISO 9001:2008
ISO 9001:2008
ISO 9001:2008
SSW Composition
(Subsystem for management of switchover)
ISO 9001:2008
UVPS ELEMENTS
(Vital power switch unit)
Reserve
Normal
UVPS
AOVD VP12V
VP N
AFM
VP12V AOVD
AFM
VP R
ISO 9001:2008
ISO 9001:2008
VP Card
ISO 9001:2008
AOVD Card
AOVD card: measures output power of all the system VPs (both
Normal and Reserve) using a fail-safe circuit (class I hardware).
Using the EOVCM card, this measurement supplies VP
"ON/OFF" status to the ULE RCHK module. It is also used by the
SLE to guarantee that in vital mode there is only ever one VP
"ON".
ISO 9001:2008
ISO 9001:2008
ISO 9001:2008
ASCV to ASCV
Communication
SLE N
SLE R
TX
SLE
SLE N
N
SLE N
ELH
ELH
Modem
Modem
SLE R
ELH
UCS
UCS
Modem
SLE
SLE R
R
UCS
Modem
ISO 9001:2008
Modem
Modem
RX
ISO 9001:2008
ELH
SUP_AL5.
ISO 9001:2008
CRSA2
SUP_AL15.
ISO 9001:2008
In Service
Yellow
Stand-by
Red
Non active
FRONT VIEW
REAR VIEW
ISO 9001:2008
ISO 9001:2008
SDM operations
NVIO
module
SDM
ISO 9001:2008
NVIO
module
ULEN
SDM / ULEs
serial
connections
SDM COMPUTER
ULE R
ASCV INTERFACES
ISO 9001:2008
TROUBLESHOOTING OPERATIONS
ISO 9001:2008
Type of ERRORS
Resetting Error
a Resetting Error is an error that cause hardware RESET to the ULE who generated it.
This is the safe reaction of the ASCV system against un-safe failures. The Reset stops all
vital function of the ULE and forces a restart of the ULE. The non-vital functions are not
completely affected by the reset, because the diagnostic information has to be dispatched
always.
A Reset put the SLE status to "non-active"; the reset has no effect to the standby SLE
which, if available become "in-service" immediately or, if already "in-service", continues its
tasks normally.
Non Resetting Error
a Non Resetting Error is a light error that cause a degrade of the SLE who generated it.
There is no safe reaction of the ASCV system because the non-resetting error is a safe
failure mode of the equipment.
This means that the SLE continues its tasks but a function is no longer available; an
automatic switchover of the SLE, if the failure is raised by the in-service SLE, is performed
in order to keep in service the SLE less degraded.
Warning
a Warning, as the non-resetting error, is a light error that may cause a degrade of the SLE
who generated it. There is no safe reaction of the ASCV system because it is a nonresetting error is a safe failure mode of the equipment.
For warnings there is no automatic switchover of the SLE, if the in-service SLE raises the
failure; the SLEs continue their tasks.
Information
Information is not referring to any anomaly but to confirm a status or a STOP_ALARM, in
fact normally; when errors stop the message that notify the normal function is an
information.
ISO 9001:2008
ERRORS LEVEL
Most important
Warning
Less important
Information
ISO 9001:2008
1
2
3
4
5
6
ISO 9001:2008
ISO 9001:2008
Any Questions?
ISO 9001:2008
THANK YOU