Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 14

S ITE M A S TER

INNO DS8000B

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

SETTIN G TH E LAN G U AG E
Choose the Language from
Restart
Click
thethe
Instrument
device.
Settings
soft key.
Select
Press
Enter.
language
soft
key.
the
System
pop up menu. Use Up/Down
key.
Key.
Ente
r
English
Chinese

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

DTF ( DISTANCE TO FAULT) MODE

ROCEDURE:
o
o
o
o
o
o
o
o

Enter the Start and Stop Frequency or choose the Band from Band List key
Choose which type of cable is used. Click Cable List menu.
Calibrate the device.
Set the total distance i.e. from NodeB to Antenna port (length of Jumper
Cablesindoor and outdoor, and Feeder Cable)
Set the Max and Minimum Amplitude, click Amplitude (1) soft key.
Set the Marker (4) . Marker 1 (indoor jumper), Marker2 (Feeder), Marker3
(outdoor Jumper)
Press Hold (+/-) button to start the measurement.
Press Peak (6) button to see the maximum value of your measurement
and see the corresponding distance from your marker.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
FREQUENCY BAND

Enter the Start and Stop Frequency or


choose the Band from Band List key.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
CABLE TYPE
Choose which type of cable is used.
Click Cable List menu.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
CALIBRATE: OPEN

Calibrate the device. Press Cal button key.

Connect OPEN to RF port and then press continue.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
CALIBRATE: SHORT

If OPEN calibration is completed,


Connect SHORT to RF port and then press continue

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
CALIBRATE: LOAD

If SHORT calibration is
completed,
Connect LOAD to RF port and
then press continue.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
DISTANCE

Set the total distance i.e. from NodeB to Antenna port (length o
Jumper
Cables--indoor and outdoor, and Feeder Cable), then press
Enter key.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
AMPLITUDE

Set the Max and Minimum Amplitude, press Amplitude (1) soft k
Max
(top)
Min

Max value should be higher than the VSWR alarm value . For example, fr
LMT MML DSP VSWR, the value measured is 280(.01), Max value should
at least 4 or 5.
Min value should at least be the ideal value, 1.
Created by: Engr Russell Salaza
FM Engineer
Mobily 3G Project

D TF M O D E
MARKER
Set the Marker (4) . Marker 1 (indoor jumper), Marker2 (Feeder),
Marker3
(outdoor Jumper)
Mark
er
Mark
Selec
er
t
Off
on

Mark
er
Edit

Mark the length of your cable, say indoor jumper


cable=3m, feeder cable=35m,outdoor jumper
cable=3m. M1=3, M2=38, M3=41.

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
RUN/MEASUR
Connect the RF cable to the RF Port.
E
Press Hold (+/-) button
to start the
measurement

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
PEAK VALUE

o Press Peak (6) button to see the maximum value of your


measurement
and see the corresponding distance from your marker.

Settings:
START FREQ =1920
Mhz
STOP FREQ = 2170
Mhz
CAL ON
DISTANCE = 40m
M1=4m

M1

M1:
3.9m/2.0

Created by: Engr Russell Salaza


FM Engineer
Mobily 3G Project

D TF M O D E
LOAD SET-UP

o If you have saved set-up configuration ( .sta), you can load it


using the Load
Button (7) . This will save time by not performing the calibration
for the equipment.

Only
change
the
Cable
type,
Distanc
e,
Marker
and or
Amplitu
de if
necessar
y.