Circuit Breakers: Presented by Ajay.S 11EE02
Circuit Breakers: Presented by Ajay.S 11EE02
PRESENTED BY
AJAY.S
11EE02
Content
A circuit breaker is an
automatically-operated electrical
switch designed to protect an
electrical circuit from damage
caused by overload or short circuit.
Its basic function is to detect a
fault condition and, by interrupting
continuity, to immediately
discontinue electrical flow.
Advantages:
Oil has good dielectric strength.
Low cost.
Oil is easily available.
It has wide range of breaking capability.
Disadvantages:
Slower operation , takes about 20 cycles for arc quenching.
Advantages:
Disadvantages:
High initial cost due to creation of vacuum.
Surface of contacts are depleted due to metal vapours.
High cost & size required for high voltage breakers.
Advantages:
High speed operation as compared to OCB.
Ability to withstand frequent switching.
Facility for high speed reclosure.
Less maintenance as compared to OCB.
Disadvantages:
Little moisture content prolongs arcing time.
Pressure should be checked frequently for frequent
operation.
Risk of fire hazards due to over voltages.
It cant be used for high voltage operation due to prolonged arc
quenching.
Advantages:
Very short arcing period due to superior arc quenching
property of SF6 .
Can interrupt much larger currents as compared to other
breakers.
No risk of fire.
Low maintenance, light foundation.
No over voltage problem.
There are no carbon deposits.
Disadvantages:
SF6 breakers are costly due to high cost of SF6.
SF6 gas has to be reconditioned after every operation of the
breaker, additional equipment is required for this purpose.
PRINCIPLE OF OPERATION :
MCB is a device which operates on the two metallic plates for
the protection against over-load & short circuit.
CLASSIFICATION OF MCBs:
1. L-Series MCB for Lighting Circuits:Suitable for resistive Load installation with Low
& Steady Currents like heaters , ovens, geysers, electric
irons , etc. The L-Series MCBs are also used for
protection of distribution equipment like wires, Cables,
metering equipment etc.
2.G-Series MCB for Motor Circuits:It is suitable for use in installation with high
inrush current peaks which require closer over-load
protection. These include inductive Loads such as motors,
A.C. transformers , halogen fluoresent sodium vapour
lamps,machine tools etc.
APPLICATION OF MCB:
They are required in homes, offices, shops distribution
boards for protection of individual circuit & complete wiring
system in that buildings through main circuits.
Whatever be the application, these MCBs
O protection.
offer perfect over-load & circuit
N
OF
F
TYPES OF ELCB:
I. Voltage Operated:They Provide a major advance in safety for mains
electrical supplies with inadequate earth impedance.
II. Current Operated:They Provide protection against earth leakage, through the
details & method of operation are different.
PRINCIPLE OF OPERATION:
It is a current operated device designed to operate when a
leakage current exceeds a pre-determined value. It essentially
consist of an operating coil & a trip mechanism which operates
contacts controlling the supply to the circuit concerned.
Consider a single-phase circuit. The two supply wires i .e. phase
& neutral are fed through separate winding of current transformer
as shown in the fig: another
winding controls the tripping
mechanism.
Ip = In
Therefore, the fluxes linking the phase & neutral conductors
are equal in magnitude & opposite in direction. Thus, no fluxes
links with tripping. Winding.
ADVANTAGES :
They are less sensitive to fault conditions , therefore have
less nuisance strips.
They can be arranged to protect against
cable damage only.
And not strip on faults in down line
installations.
DISADVANTAGES:
They do not detect faults that dont pass current through the
CPC to the earth rod.
They do not allow a single building system to be easily spilt
into multiple sections with independent fault protection,
because earthing system are usually bounded to pipe work.
ELCBs introduce additional resistance & an additional point
of failure into earthing systems.
CONCLUSION:
Therefore, we conclude that circuit breaker is the most essential
part of the electrical networks as it protects every device from
damage. It helps us to detect the fault and area affected by it.
Nowadays vacuum and SF6 circuit breakers are widely used due
to their reliable and fast operations.