Professional Documents
Culture Documents
Tunable Diode Laser Analyzer: Bild Durch Klicken Auf Symbol Hinzufügen
Tunable Diode Laser Analyzer: Bild Durch Klicken Auf Symbol Hinzufügen
LS4000
Tunable diode laser analyzer
ABB Group
August 16, 2012 | Slide 1
LS4000
Highest precision for harshest conditions
Ideally suited
ABB Group
1/29/16 | Slide 2
LS4000
Product overview
Transmitter unit
Purging flange
Receiver unit
Junction box
Power supply
Analog outputs
Relay outputs
ABB Group
1/29/16 | Slide 3
Key features
Measurement of O2 (Vol%)
Stand-alone operation
LS4000
Key Selling Points
ABB Group
1/29/16 | Slide 4
High precision
LS4000
High precision
Highly selective measurement is virtually cross
interference free.
Target
absorption
line
Absorption lines of
accompanying
gases
ABB Group
1/29/16 | Slide 5
LS4000
High precision
Lowest detection limit allows highly accurate
measurements.
Detection limits [ppm] for O2 compared to competing products
ABB Group
1/29/16 | Slide 6
LS4000
Suitable for harsh process conditions
In situ, direct measurement of hazardous
gas streams
ABB Group
1/29/16 | Slide 7
Up to 1500C (2732 F)
LS4000
Fast and direct
No sample transport or conditioning
No sample extraction or
conditioning
Fast response
ABB Group
1/29/16 | Slide 8
LS4000
Safe, compact and easy
Flameproof housing (Ex-d)
ABB Group
1/29/16 | Slide 9
International certifications:
ATEX
IECEx
CSA
LS4000
Safe, compact and easy
No nitrogen purging for O2
measurement
ABB Group
1/29/16 | Slide 10
LS4000
Safe, compact and easy
Insensitive to vibrations through
compact and lightweight design
- 40 %
ABB Group
1/29/16 | Slide 11
LS4000
Safe, compact and easy
Ease of maintenance
ABB Group
1/29/16 | Slide 12
Easy to dismount
LS4000
Target applications
KEY INDUSTRIES FOR TDL ANALYZERS
Oxygen
(O2)
Chemicals,
Oil & Gas
Iron &
Steel
Power &
Waste
Process control
and optimization
(Explosion)
safety
Cost savings
Secure safety
Legend:
ABB Group
1/29/16 | Slide 13
Environmental
protection
LS4000
How to measure O2
ZrO2
Paramagnetic
TDL Analyzer
TDL Analyzer
is preferable
Measuring
point
In situ,
single point
Extractive,
single point
In situ,
cross stack
for large
boilers/ducts
Response time
> 10 s
3-10 s plus
transport time
<2s
if fast response
is required
Influenced by
Combustibles
NO,NO2,various
hydrocarbons
Virtually none
Process T, p
T < 1400 C
p < 1.5 bar
T < 50 C
p < 1.2 bar
T < 1500 C
p < 20 bar
Corrosive gas
streams
Sensor is in
contact with gas
Sensor is in
contact with gas
Sensor is not in
contact with gas
Costs
+++
++
(Cross sensitivity)
ABB Group
1/29/16 | Slide 14
for
challenging
applications
if costs are
acceptable
Summary
LS4000 is ABBs new in-situ laser analyzer
High precision
Fast response
ABB Group
1/29/16 | Slide 15
Direct measurement of
hazardous gas streams
Ease of maintenance
- one minute to dismount
ABB Group
August 16, 2012 | Slide 16