WHATS NEW IN

PV-ELITE 2016
NAGARAJAN S
APPLICATION ENGINEER

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

ABOUT IMAGEGRAFIX
Company Name

Founded :

2006

Head office

Head Quarters

ImageGrafix Engineering Services Pvt. Ltd

Chennai, India
:

Group Companies

Dubai, UAE (Since 1996)


:

-ImageGrafix Software FZCO, Dubai.

-ImageGrafix Engineering Services Pvt. Ltd (Bangalore, Hyderabad, Delhi,


Mumbai,
Vadodara, Kolkata & Pune)
-ImageGrafix Canada Inc, Canada
-ImageGrafix Qatar
and growing
CLICK :TO70+EDIT
MASTER TITLE STYLE

Number of Employees

(Including our Group Companies)

Web address :

5/10/16

Click to edit Master text styles

www.image-grafix.com , www.iges.in

IMAGEGRAFIX GROUP
ImageGrafix Software FZCO,
Dubai, UAE
Corporate Head Quarter
ImageGrafix Qatar
Doha, Qatar

IGES,
Western Region

IGES,
Mumbai
IGES,
Vadodara

ImageGrafix Engineering Services (IGES) ,


Chennai, Indian Head Office

IGES,
Southern Region

IGES,
Bangalore

ImageGrafix Canada Inc


Toronto, Canada

IGES,
Northern Region

IGES,
Eastern Region

IGES,
Hyderabad

CLICK TO EDIT MASTER TITLE STYLE

IGES,
Pune

5/10/16

IGES,
New Delhi

IGES,
Kolkata

Click to edit Master text styles

IGES DIVISIONS

Engineering
Software Solutions

CLICK TO EDIT MASTER TITLE STYLE


Engineering
Training
5/10/16

Click to edit Master text styles

Engineering Services
4

ENGINEERING SOFTWARE
SOLUTIONS
Intergraph is one of the world's leading engineering software companies. ICAS revolutionized pipe
stress analysis with CAESAR II . Other software are CADWorx Plant Pro, PV Elite & TANK and
GT Strudl.
Pipe Flow Analysis & Modeling Software, with an unmatched combination of capability and ease-ofuse, our software products are used in almost any industry in which you find piping systems.

Authorized Partner for Autodesk AEC & Infra Products and Solutions.

Flaretot is a total flare system design & analysis software provides an integrated solution for all
aspects of Flare System design, revamp or auditing

PRG

Paulin Research Group develops FEA software for the Petrochemical, Power, Offshore and Chemical
Industries. Solutions: FE/Pipe , Nozzle Pro, FE 107,Matpro Etc.,

CLICK TO EDIT MASTER TITLE STYLE

Click
edit many
Master
text types
styles
Dimensional Solutions features five distinct programs that
canto
design
different
of
foundations Foundation 3D , Mat3D, Shaft 3D,DS Anchor and Combined 3D.

5/10/16

PV ELITE 2016 NEW FEATURES


Code updates
Productivity Enhancements
Analysis & Calculations
Output Reports
Documentation
QA

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

CODE UPDATES
ASME VIII-1 and VIII-2 mandatory code updates
Hundreds of material updates per ASME 2015.
Updated PV Elite to include the latest updates from Section VIII
Appendix 26 of the ASME code, 2015 Edition
Updated PV Elite to include the latest wind and seismic updates
from the IBC code, 2015 Edition.
Updated PV Elite and CodeCalc to include the latest tube sheet
updates from the PD5500 code, 2015 Updates.
Updated PV Elite to include the latest updates from the B16.5
code, 2013 Edition

CLICK TO EDIT MASTER TITLE STYLE

Updated PV Elite and CodeCalc by adding fields for the minimum Click to edit Master text styles
and maximum operating pressures for the shell and channel sides
of a Tubesheet from the ASME-UHX 2015 Edition
5/10/16

PRODUCTIVITY
ENHANCEMENTS
Re-pad Graphics and Appendix 2 flange with Appendix 2 blind flange and nozzle
on blind flange
Force/moment symbols that symbolize piping loads
Holes in skirts
Model edges (weld lines, shows junction between cylinders and other
components)

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

PRODUCTIVITY
ENHANCEMENTS
Updated PV Elite by adding options to select and deselect all the nozzles on
the Change Nozzle Materials dialog.
Updated PV Elite to include fields for drawing and revision information. The
new fields, Reference #, Revision #, Client Name, Drawing #, and Contract
Date were added to the Heading tab. The information entered in the new
fields displays on the cover page of output reports.
Model export to Intergraph S3D VUE visualization file format (this was a huge
project).

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

ANALYSIS
Added three new inputs in PV Elite on the Seismic Data tab that allow for additional factors to
be considered during seismic analysis. The new inputs, Consider the Rotational Force Effect,
Site Velocity, and Specification Factor allow for rotational forces to be calculated when
performing seismic analysis according to the Mexico Sismo (2008) seismic design code.
Updated PV Elite to allow you to calculate the effective wind diameter using only a few inputs.
The new Special Effective Wind Diameter dialog contains inputs that allow you to easily
calculate the wind diameter for a vertical column, making it quicker to determine the foundation
loads necessary for the structure.
Updated PV Elite by adding an additional hydro-test option for ASME Division 1. A new App.
27-4 option was added to Hydro test Type on the Design Constraints tab. This new option
allows you to test that glass-lined vessels meet the requirements of Appendix 27-4 of ASME
Division 1.

CLICK TO EDIT MASTER TITLE STYLE

Fixed an issue in PV Elite in which the software did not recognize certain materials as being
in the creep range. The material database was updated to contain accurate creep range
Click to
Master
text
styles
temperatures for applicable materials. Creep range temperatures
foredit
a material
now
display
in
red on the Material Properties dialog.
5/10/16

10

ANALYSIS
When you selected one of the Brn. & Young options in Basering Design Option, you were able
to select any option in Method for Thinness Calc, though the software only analyzed the vessel
according to the Neutral Axis Shifted method. The software now only uses the Neutral Axis
Shifted method for Brn. & Young basering design options.

When you entered a temperature for a metric material that resulted in the value of the
operating allowable stress nearing the high-end of its range, the temperature violation
message displayed. However, when you entered a temperature that resulted in the allowable
stress value narrowly exceeding its range, the temperature violation message did not display,
but the software reset the allowable stress value to zero. The temperature violation message
now only displays when the material temperature exceeds its allowable range.
Created a new input in PV Elite to allow you to enter the thickness of the weld between a flat
head and the attaching element. Maximum Weld Thickness (Head or Junction) was added to
the Additional Element Data section of the Welded Flat element. The software uses the value
Click
totreatment
edit Master
text styles
entered in the field to determine if the weld requires post weld
heat
(PWHT).

CLICK TO EDIT MASTER TITLE STYLE

5/10/16

11

ANALYSIS

Fixed an issue in PV Elite in which the piping attachment angle diagram on the Drain Piping Input
dialog did not accurately reflect how the software functioned. Previously, the diagram on the Drain
Piping Input dialog displayed 0 along the longitudinal axis, and 90 clockwise from that. However,
the implementation in the program differed. The issue was resolved and the piping attachment
angle diagram now reflects the implementation in the program with the default angular direction
and orientation.

Regarding area of reinforcement calculations for cones, which


are not lines-of-support, that are attached to short cylinders.
Previously, the software used the artificial length of the cylinder
for the line of support value. The software has been updated to
TOlengths
EDIT
MASTER
STYLE
use CLICK
the individual
of the
cylinders on TITLE
each end to
Click
edit
Master text
styles
incorporate the equations from ASME VIII,
Divto1,
Appendix
1-5(e).

5/10/16

12

ANALYSIS
When analyzing a vessel with legs welded to a jacket, the software used the diameter of the
shell when performing WRC 107 leg calculations. The software now uses the diameter of the
jacket when performing the WRC 107 leg calculations.
When the software displayed a code violation warning when the diameter ratio exceeded 1.5 for
nozzles on vessels designed according to the ASME Division 2 code, even though this did not
violate the code. The software has been updated by adjusting the parameters that result in the
display of the warning message.
Updated certain weld neck flange calculations in PV Elite, such as those for static pressure and
weld thickness, to allow the software to analyze weld neck flanges as sump items. When adding
a body flange, you can select the Sump Head check box to designate the flange to be the sump
of a selected nozzle.

CLICK TO EDIT MASTER TITLE STYLE

Updated the Saddle Dialog box in PV Elite to include an option to enter the distance from
tangent to tangent. The new Tangent to Tangent Distance field
allows
you toMaster
more accurately
Click
to edit
text styles
calculate the effective distance (L) by entering the tangent to tangent distance from the first head
to the last head.
5/10/16

13

ANALYSIS
Updated PV Elite to display a nozzle that is offset from the centerline and a lateral at the same time.
Previously, the software did not allow a negative value in Centerline Tilt Angle. The software now allows you
to enter a negative value in Centerline Tilt Angle to allow you to point angled nozzles in more directions.
Fixed an issue in PV Elite in which the software incorrectly calculated the structural height of certain
vessels for IBC 2012 earthquake calculations. Previously, when a vessel had multiple cylinders, with a sump
head in the first cylinder, the software calculated the structural height only up to the sump head. The
software has been updated and the software now calculates the structural height as the entire length of the
vessel.
Fixed an issue in CodeCalc in which the software defined the value of as and ac as zero for floating
tubesheet calculations in the ASME Tubesheet module. According to ASME UXH 14.3, the value for ac is
defined as the radial channel dimension, which for configuration B is equal to Gc/2, where Gc is the diameter
of the channel gasket load reaction and the value of as is equal to ac. When you select (FL,B) Floating,
gasketed, extended as flange as the tubesheet type, the dimension for Gc should not be equal to zero.
Fixed an issue in PV Elite regarding the hoop stress value in certain calculations for the EN-13445, PD
5500, and ASME Section VIII, Division 2 codes. Previously, the software did not consider the hoop stress
due to hydrotest pressure for calculations in the aforementioned codes. The software now considers the
hoop stress and calculates a non-zero stress value.

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

14

OUTPUT
Fixed an issue in PV Elite in which a certain print option did not work in the PV Elite Output
Processor. Previously, when you clicked Print and then selected PV Elite PDF Printer, the
software displayed an error message. The Print icon was removed from the File panel of the
Output Processor. You can now press CTRL + P to display the Preview/Print tab.
Fixed an issue in CdeCalc in which the output report displayed incorrect input data

Added a clarifying message to the ASME TS Calc report regarding minimum length calculations
for simply supported UHX fixed tube sheets.
Fixed an issue in CodeCalc in which the output report displayed incorrect input data for Partition.
Gasket Column for Gasket Seating.
Added a warning message concerning MDMT calculations in PV Elite. Previously, PV Elite
calculated the MDMT for carbon steel materials thicker than four inches even when impact testing
and PWHT were not performed. The software now displays a warning message that impact
testing and PWHT must be done before MDMT calculations are performed. The warning
message displays on the Internal Pressure Calculations report and the MDMT Summary report.

CLICK TO EDIT MASTER TITLE STYLE

Fixed an issue in PV Elite regarding the Rnc value in perpendicular nozzle calculations in formed
Click to edit Master text styles
elliptical heads. The software has been updated and now displays a clarifying note on the nozzle
output reports when the Rnc value is equal to Rn/sin(theta).
5/10/16

15

OUTPUT
Updated PV Elite to include the saddle weight in the total operating weight for certain
saddle analysis calculations. When friction force calculations are performed during the
saddle analysis, PV Elite now includes the saddle weight in the total operating weight.
Fixed an issue in CodeCalc in which the Analysis tab on the Floating Head module did
not display a failure. Previously, when a required thickness value was not met in the
Floating Head module, the value did not display in red in the Analysis tab as a sign of
failure; however, when the file was analyzed, the failure displayed on the analysis
report. The software has been updated and now the failure immediately displays in red
on the Analysis tab.
Updated PV Elite by adding an option to separate the foundation load information.
Previously, the software only displayed base ring and foundation load information on the
Vessel Design Summary report. You can now select Foundation Loads on a New Page
on the Configuration dialog which will result in the base ring and foundation load
information displaying on the new Foundation Support Summary report. A new base
ring Cross Section View sketch also displays on both the
Vessel
Design
Summary
Click
to edit
Master
text styles
report and Foundation Support Summary report.

CLICK TO EDIT MASTER TITLE STYLE

5/10/16

16

DOCUMENTATION
There are few updates in the documentation like
Updated an image in the PV Elite documentation to be more
accurate. The image has been updated and correctly illustrates the
length of the outer faces ending at the tube sheet.
Updated the nozzle flange is considered in Flange Distance to Top.
Added definitions for the fields on the Drawing Options dialog box to
the CodeCalc User's Guide and Online Help.

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

17

CLICK TO EDIT MASTER TITLE STYLE


Click to edit Master text styles

5/10/16

18