Professional Documents
Culture Documents
Intelligent Power Consumption Decrease (IPCD)
Intelligent Power Consumption Decrease (IPCD)
Consumption Decrease
(IPCD)
TRX Power Amplifier
Intelligent Shutdown
Definition of (IPCD)
IPCD refers to the solution of
decreasing power consumption of the
BTS or even in a coverage area using
hardware or software without
deteriorating network performance
and BTS hardware performance.
Cabinet
power
consumptio
n
TRX power
consumptio
n
Benefits( IPCD)
Save energy
Reduce emission
Save capital expenditure (CAPEX) by
decreasing the BTS power consumption.
Prolong the serving time of the storage
battery and shorten the serving time of the
generator
Prolong the serving time of cells and reduce
the number of storage batteries, reducing
CAPEX.
Parameter
Allow Dynamic Shutdown of
TRX by BSC
Prohibit Power
Saving End Day
Prohibit Power
Saving End
Month
Allow Dynamic
Shutdown of
TRX
Allow Dynamic
Shutdown of
TRX
TRX Power-on
Protection Time
MML Commands
Impa
ct
MML Command
Parameter
BSC
SET BSCDSTPA(Optional)
BSC
SET BSCDSTPA(Optional)
BSC
SET BSCDSTPA(Optional)
BSC
ADD
BSCDSTPADATE(Mandatory
)
BSC
ADD
BSCDSTPADATE(Mandatory
)
BSC
ADD
BSCDSTPADATE(Mandatory
)
Activation Procedures
SET BSCDSTPA: Set Allow Dynamic Shutdown of TRX by BSC to
YES(Yes), and set Time When the Function Is Enabled and Time
When the Function Is Disabled according to the actual condition.
SET GCELLBASICPARA: Set Allow Dynamic Shutdown of TRX to
YES(Yes) to enable the TRX power amplifier intelligent shutdown
function for the cell. (to enable the TRX power amplifier intelligent
shutdown function for the cell.)
SET GTRXDEV: Set Allow Dynamic Shutdown of TRX to YES(Yes)
(allowing the BSC6900 to shut down the power amplifier of a TRX based
on the traffic volume.)
Optional: ADD BSCDSTPADATE: In this step, set the period in which
the TRX power amplifier intelligent shutdown function is disabled. In the
period of heavy traffic, this function needs to be disabled.
Verification Procedure
Wait for about five minutes. Then, Run the
MML command DSP GTRXSTAT to query
the value of Close TRX Power. Expected
result: The value of Close TRX Power is
Yes.
Deactivation Procedure
SET BSCDSTPA: Set Allow
Dynamic Shutdown of TRX by
BSC to NO(No).
SET GCELLBASICPARA: Set Allow
Dynamic Shutdown of TRX to
NO(No).
SET GTRXDEV: Set Allow Dynamic
Shutdown of TRX to NO(No).
Activation Example
/*Activation procedure*
/ //Enabling the TRX Power Amplifier Intelligent Shutdown function for the BSC
SET BSCDSTPA: BSCDynSwitchTrxPAAllow=YES, StartTimeTACloseTrxPA=19&00,
EndTimeTACloseTrxPA=24&00;
//Enabling the TRX Power Amplifier Intelligent Shutdown function for a cell
SET GCELLBASICPARA: IDTYPE=BYID, CELLID=1, DYNOpenTrxPower=YES;
//Enabling the TRX Power Amplifier Intelligent Shutdown function for a TRX
SET GTRXDEV: TRXID=2, CPS=YES;
//Setting the period during which the TRX Power Amplifier Intelligent Shutdown
function is prohibited
ADD BSCDSTPADATE: DateRangeIndex=1, StartMonthDSTPA=JAN, StartDayDSTPA=10,
EndMonthDSTPA=FEB, EndDayDSTPA=10;
Deactivation Example
/*Deactivation procedure*/
//Disabling the TRX Power Amplifier Intelligent Shutdown function for
the BSC
SET BSCDSTPA: BSCDynSwitchTrxPAAllow=NO;
//Disabling the TRX Power Amplifier Intelligent Shutdown function for a
cell
SET GCELLBASICPARA: IDTYPE=BYID, CELLID=1,
DYNOpenTrxPower=NO;
//Disabling the TRX Power Amplifier Intelligent Shutdown function for a
TRX
SET GTRXDEV: TRXID=2, CPS=NO;
References
GBSS14.0 Feature Activation
Guide(06)(PDF)
GBSS9.0 Feature Parameter
Description (08)(HedEx)