Presentation On RC Design

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 19

Presentation on RC Design

Group Member : Sahidzuwan Bin AG.


Salleh
(2013289062)
Erwin Ashley Dalang
(2013224378)
Haziq Farid Bin Wajidi
(2013267464)

Introduction
> Design for double storey house
Consist of designing :
1. Slab
2. Beam
3. Staircase
4. Column
5. Pad Footing

Slab Design
Ground floor Slab (GF-fs7)
Dimension = 1700mm x 1200mm
One-way slab
One short edge discontinue
Total Design Load = 8.9 KN/M

Key Plan

Slab Moment Design


Short Span

Msx1 = 0.53KNM
Msx2 = 0.713KNM
Effective depth =
85mm

Long Span

Msy1 = 0.39KNM
Msy2 = 0.474KNM
Effective depth =
85mm

Main Reinforcement Design


Short Span
Med = 0.53knm/m
Z = 0.95d
AS,Req = 12.09 mm
As,prov = 314mm
(10H-200)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As,, Max
OK!

Short
Med Span
= 0.713knm/m
Z = 0.95d
AS,Req =20.3mm
As,prov = 314mm
(10H-200)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As, Max
OK!

Main Reinforcement Design


Long Span
Med = 0.359knm/m
Z = 0.95d
AS,Req = 10.22 mm
As,prov = 314mm
(10H-250)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As,, Max
OK!

Long
MedSpan
= 0.474knm/m
Z = 0.95d
AS,Req =13.49 mm
As,prov = 314mm
(10H-250)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As,, Max
OK!

Shear Design
Short span
Vsx1 = 4.85KN
Vsx2 = 0 KN

Short span
Vsy1 = 3.85KN
Vsy2 = 2.56KN

Ved = 4.85 kn
K = 0.0036
VRd,c = 42.43
KN
Vmin = 42.07
KN
VRd,c > Ved

Deflection and Cracking


Design
Deflection
l/d
l/d
l/d

= 14.12
allowable = 3081.95
actual < l/d allowable
actual

Cracking
H = 125
Main bar = 375mm
< 400mm
Sec Bar = 437.5
mm < 450 mm
Safe from cracking

Detailing

Beam design

Pad Footing
Design
Data

Dead Load = 169.6 kn


Live Load = 14.3 kn
Nominal Cover = 35 mm
Footing Depth = 350 mm
Soil Bearing Capacity = 80 kn/
Assumed Bar Diameter = 16 mm
Column Size = 400 400 mm

Footing
size Estimation 1.6 m 1.6 m

1.60 1.60 = 2.56 > area footing


required (2.53 )
Loading analysis, Ned = 250.41 kn
(ignore self-weight)

Soil
pressure at ultimate load
= 90.51 kn/m
Soil pressure per meter length, 144.86 kn/m
Movement at level arm,=0.6 m
Maximum moment at the force of the
column
M = 26.08 knm

Main Reinforcement
Minimum

effective depth,d = 291


mm
Moment, M = 26.08
z = 0.9d
= 228.9
= 629.49
=
=804(4H16)
< < OK!

Vertical Shear
Design

vertical shear force, = 124.44


kn
Design shear resistance,
= 138.77 kn
= 201.71 kn
<

Punching Shear

Critical
perimeter,
Critical area within perimeter = 2.16
Punching shear force, = 36.22 kn
Punching shear stress, = 0.024 N/
Shear force resistance, =0.43 N/
<

Max

shear resistance, = 4.5 N /


Max shear resistance, = 0.54N /
< ok!!

Cracking
Fs
= 626.11 N /
Max bar spacing = 504.67 mm > 225
mm :fail!!
Change mainbar to 8H10 = 217.14
mm

You might also like