Professional Documents
Culture Documents
Feed Water Treatment & Monitoring: 14th June 2007 1
Feed Water Treatment & Monitoring: 14th June 2007 1
TREATMENT &
MONITORING
Ammonia in Feed
Corrosion rate
9-9.2
pH
14th June 2007
Ammonia addition
Metering pumps are used for ammonia addition
Ammonia procured from market is 25% and is
diluted to maintain 450 to 500 ppb of ammonia in
feed water.
Ammonia is measured in condensate, feed and
steam
HPT
IPT
LPT
Condenser
De aerator
Boiler
HP Heaters
CPU
LP Heaters
DOSING POINTS
14th June 2007
Condensate polishers
All 500MW units require CPU
Mixture of Cation and Anion resins
CEP discharge is fed into the CPU @ 600m3/hr per
CPU
Total 2 CPUs per unit
Regeneration of CPU
Resin is brought to the regeneration area in the DM
plant
Cation & Anion resins are separated by water flow
and regenerated by acid and alkali respectively.
They are again mixed, washed free of chemicals
and put into the CPU Vessel
Sample
Limits
pH
C or S
9.2-9.5
Silica, ppm
C or S
0.4 (on
MCR)
Chloride, ppb
C or S
<50
Phosphate
1-4
Conductivity, S
50 Max
Sample
Limit
pH
8.8-9.2
Silica, ppm
C or S
0.02
Conductivity , S
2.5-5.5
Hardness(Caco3)
DM Plant Outlet
IPT
HPT
LPT
Condenser
De aerator
FEED WATER
Parameters
Sample
Limit
pH
C or S
8.8-9.2
DO, ppb
<5
Hydrazine, ppb
Silica, ppm
15-30
C or S
Conductivity, S
2.5-5
Limit
pH
6.8-7
Silica, ppm
0.02
Conductivity , S
1.0 Max
Boiler
HP Heaters
LP Heaters
Condensate(CEP discharge)
Parameter
<0.02
Hardness Caco3,ppm
Parameters
Sample
pH
Legend:
C = Continuous, Online
S = Grab, Once in shift
Limit
9-9.2
ACC, S
2.5-5
DO, ppb
10-20
Silica, ppb
C or S
<10
Ammonia,ppm
Hardness(Caco3)
0.5 9Max
10
11