Professional Documents
Culture Documents
Welcome To Midas SAB Event: Presented By-Shishir Kumar Technical Engineer Midas It
Welcome To Midas SAB Event: Presented By-Shishir Kumar Technical Engineer Midas It
Welcome To Midas SAB Event: Presented By-Shishir Kumar Technical Engineer Midas It
MIDAS
SAB Event
Seismic Assessment
of Buildings
Midas Gen
One Stop Solution for
Buildings & General Structures
Why?
Why?
Systematic
Systematic Rehabilitation
Rehabilitation Method
Method
Irregularity
Irregularity
The ratio of the average shear DCR of any story to that of an adjacent
story in the same direction exceeds 125%
Diaphragm above the story under consideration is not flexible and, for a
given direction, the ratio of the critical element DCRs for primary elements
on one side of the center of resistance of a story, to those on the other
side of the center of resistance of the story, exceeds 1.5
A modal response spectrum analysis shall be performed for the structure using sufficient modes to capture 90% mass
participation. Second response spectrum analysis shall also be performed, considering only the first mode participation.
NDP shall be considered if the shear in any story resulting from first modal analysis exceeds 130% of the corresponding story
shear from second modal analysis.
Time history analysis shall be performed with no fewer than three data sets of ground motion time histories
For each data set, the 5%-damped site-specific spectrum of the scaled horizontal components shall be constructed.
The data sets shall be scaled such that the average value of the spectra does not fall below 1.4 times the spectrum
for the design earthquake for periods between 0.2T seconds and 1.5T seconds (where T is the fundamental period of
the building).
Where three time history data sets are used in the analysis of a structure, the maximum value of each response
parameter (e.g., force in a member, displacement at a specific level) shall be used to determine design acceptability.
Where seven or more time history data sets are employed, the average value of each response parameter shall be
permitted to determine design acceptability.
Q&A