Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 32

1xEV-DO Element Management System

(EMS)
Mallik Vagvala

Proprietary Information - Lucent Technologies

Topics
Introduction

Introduction to the EMS

EMS Web Access

Web Server Groups

New User Administration

Supported Client Hardware Configurations

Supported Client OS

Supported Browsers

Proprietary Information - Lucent Technologies

Topics
Configuration Management Capabilities

Launch

Container Pages

Instance Pages

Fault Management Capabilities

Graphical User Interface


High Level Concepts
Active Alarms
Summary Pages
Status Pages

Proprietary Information - Lucent Technologies

Introduction to the EMS


The EMS is the primary interface for performing operations,
administration, and maintenance on Flexent components.
Through the EMS GUI, users monitor status and perform maintenance
procedures on the Flexent network and related applications.
The EMS GUI presents information in pages. Some pages present a
graphical representation of physical hardware.
The EMS GUI is accessed from the OMP Web page using the Netscape
Communicator version 4.77 browser. The Internet Explorer browser
will be supported in a future release of the product.

Proprietary Information - Lucent Technologies

Introduction to the EMS - Scope


A Flexent network is made up of network elements (NEs), the applications that run on
network elements, and the managed resources (MRs) that are present. You can monitor and
control the listed examples of NEs, applications, and MRs through EMS pages:
Part of Flexent Network

Example under EMS Control

EMS Page

NE

Application Processor

AP Summary Page

Inter-Working Function

IWF Status Page

Packet Control Function

PCF Summary Page

Base Transceiver System

BTS Summary Page

Application

Radio Cluster Server

RCS Status Page

MR

CRC

CBR

Proprietary Information - Lucent Technologies

CDMA Equipment Status


Page

Introduction Accessing the EMS GUI

1.

Its just like web browsing:

2.

Enter your user name and


password in the dialog window
and then click the O.K. button

3.

Select the network element or


function of your choice.

Proprietary Information - Lucent Technologies

Introduction to EMS Tool Tips and Status Line


When you place the cursor
over a symbol or icon, a tool
tip Window will appear. This
will provide some help on the
ICON information.
.

Proprietary Information - Lucent Technologies

Introduction to 1xEV-DO
The 1XEV-DO system can be deployed in two distinct modes: mixed or
standalone. The 1XEV-DO system deployment mode determines the
deployment mode for the OMP.
In a standalone mode, the OMP/EMS provides Configuration, Fault, and
Performance management capabilities for the 1XEV-DO Controller, as
well as the 1XEV-DO specific components of the the associated cell sites.
In a mixed mode deployment, the OMP/EMS provide management
capabilities for the GNP-AP and its RCS application, in addition to
providing support for the 1XEV-DO controller and cell sites.
In the standalone mode, the OMP is not connected to an ECP. In the
mixed mode scenario, the OMP will be connected to an ECP.
Please note that the deployment mode discussed here applies to the
1XEV-DO system as a whole and not individual cell sites, which can also
be deployed in 1XEV-DO only or mixed mode.

Proprietary Information - Lucent Technologies

Introduction Mixed Vs Standalone Deployment

Lucent CDMA 2000 / 1XEV-DO Network


Radius
AAA

1XEV-only
HDR
cell

HDR
1XEV
Flexent Mobility
Server

DNS,
DHCP

R - P (A10 - A11)
OMP - FX

System
OMP/EMS

Dual - mode
Cell
HDR
1XEV

PDSN

Flexent EMS

PDSN

CDMA
3G -1x
RCS / AP
RCS/AP

3G -1x
CDMA
cell
cell

5ESS
DCS

ECPC

HLR

Proprietary Information - Lucent Technologies

CDMA
3G -1x
PCF

SMS Center

R -P
(A10 -A11)

EMS WEB ACCESS

EMS Web Access Web Server Groups


The following EMS related security groups are defined:
apframeconfig Controls access to the AP Frame Configuration Page
(Used for 1XEV-DO)
emscm Controls access to all EMS Configuration Management Pages
(Used for 1XEV-DO)
ompconfig Controls access to the the OMP Configuration Pages
pcfconfig Controls access to the 3G1X PCF configuration pages
ems Default EMS security group. Controls access to the rest of the
EMS GUI Pages

Proprietary Information - Lucent Technologies

EMS Web Access Web Server Groups


A default EMS user, called webuser, was originally created by the
EMS installation software.
webuser belongs to all of the EMS related security groups listed
on the previous page and therefore has complete access to all
EMS GUI pages.
The default password for webuser is webuser.
For security reasons, we encourage our users to change the
default password.
Some of our customers have removed the default user from the
access control list for security purposes.
If the webuser login has been removed, the EMS installation
software will not recreate that user.

Proprietary Information - Lucent Technologies

EMS Web Access New User Administration


The OMP platform provides a set of commands to administer
users for access to both the OMP system and the EMS Graphical
User Interface:
addompuser Used to create a new user and add/delete a user
to/from a group
passwd Used to change the UNIX and Web Server password
associated with a user.
userdel Used to delete a user from the system

Proprietary Information - Lucent Technologies

EMS Web Access Client Hardware and OS


PC
Minimum Hardware Configuration:
Pentium 500 MHz Pentium III CPU, 128 MB RAM, 20 MB client free hard
disk space

Required OS:
Windows NT 4.0 or Windows 2000

Supported Browser Versions:


Netscape Communicator 4.77 on the client PC

Proprietary Information - Lucent Technologies

EMS Web Access Client Hardware and OS


Workstations:
Minimum Hardware Configuration:
Sun Ultra 5, 128 MB RAM, 120 MB client free hard disk space

Required OS:
Solaris 8 Operating Environment

Supported Browser Versions:


Netscape Communicator 4.76 running on client workstation

Proprietary Information - Lucent Technologies

CONFIGURATION MANAGEMENT CAPABILITIES

Configuration Management Capabilities - Launch


Configuration Management capabilities are only available
through a graphical user interface.
Accessed from OMP Web Page Configuration Data icon
Access to all Configuration Management related pages is
restricted to users belonging to the emscm security group.
Top level Configuration Management Page lists all of the CM
objects in alphabetical order

Proprietary Information - Lucent Technologies

Configuration Management Capabilities - Launch

Proprietary Information - Lucent Technologies

Configuration Management Capabilities - Launch

Proprietary Information - Lucent Technologies

Configuration Management Container Pages


One container page for each object type. The page shows all
provisioned instances of a given object type.
Only the key fields associated with an object instance are
displayed on the container page.
The information on the container page can be sorted by columns
by clicking on the column header.
Clicking anywhere in a particular row navigates to the instance
page associated with that object instance.
A new object instance can be created from this page.
Selecting one of the objects on the left hand side of a container
page navigates to the container page associated with the selected
object

Proprietary Information - Lucent Technologies

Configuration Management Container Pages

Proprietary Information - Lucent Technologies

Configuration Management Instance Pages

Proprietary Information - Lucent Technologies

Fault Management High Level Concepts


Navigate to
Alarm list

Navigate to OMP Launch Page


Alarm State
Navigate to alarm
List filtered for this
object

Maintenance State
Command Buttons
Attribute information

Launch Help

Navigate to Lucent
Support Web Page

Proprietary Information - Lucent Technologies

Fault Management Active Alarms List

Proprietary Information - Lucent Technologies

Fault Management AP Summary Page

Proprietary Information - Lucent Technologies

Fault Management BTS Summary Page

Proprietary Information - Lucent Technologies

Fault Management Status Pages

Used to display status of one or more managed object instances

Allow a user to execute commands associate with the managed


object instance(s)

Allow a user to navigate to other associated managed object


instances

Allow a user to navigate to the summary page for the displayed


managed object

Allow a user to navigate to the alarm list filtered for the


particular managed object instance

Proprietary Information - Lucent Technologies

Fault Management AP Status Page

Proprietary Information - Lucent Technologies

Fault Management BTS Status Page

Proprietary Information - Lucent Technologies

Fault Management Additional Status Pages


Additional status pages include:
TP Status Page
CDM Status Page
ULAM Status Page This page is available only if the BTS is
configured as a 1XEV-DO only BTS
TFU Status Page - This page is available only if the BTS is configured
as a 1XEV-DO only BTS

Proprietary Information - Lucent Technologies

Commands Supported by EMS CLI

DGN:BTS #, TXAMP #
DGN:BTS 1, TXAMP 2! COMPLETED
ALL TESTS PASSED

OP:BTS #, TXAMP #
OP:BTS 1, TXAMP 2! COMPLETED
TXAMP Id: 2 Flex State : Active Equipage State : Equipped WARMUP STATE Shared State: Owned

RMV:BTS #, TXAMP #
RMV:BTS 1, TXAMP 2! FAILED
DEVICE IS MAINTENANCE BUSY

RST:BTS #, TXAMP #
RST:BTS 1, TXAMP 2; UCL! COMPLETED
RST SUCCESSFUL FOR TXAMP

STOP:BTS #, TXAMP #
STOP:BTS 1, TXAMP 2! COMPLETED

Proprietary Information - Lucent Technologies

Commands Supported by EMS CLI


(Cont..)

OP:BTS #, TDU #
OP:BTS 1, TDU 2! COMPLETED
TDU Id: 2 TDU Type: ETDU Flex State : Active Equipage State : Equipped Shared State: Owned

RMV:BTS #, TDU #
RMV:BTS 1, TDU 2! COMPLETED
RMV SUCCESSFUL FOR TDU

RST:BTS #, TDU # [;UCL]


RST:BTS 1, TDU 2; UCL! FAILED
CANNOT RESTORE TDU AS THE TDU IS DISABLED

STOP:BTS #, TDU #
STOP:BTS 1, TDU 2! FAILED
CANNOT STOP THE EXECUTING COMMAND

Proprietary Information - Lucent Technologies