Single-phase half-bridge inverter

Operational Details

3-wire DC source

Consists of 2 choppers, 3-wire DC source


Transistors switched on and off alternately
Need to isolate the gate signal for Q1 (upper device)
Each provides opposite polarity of Vs/2 across the load

Q1 on, Q2 off, vo = Vs/2

Peak Reverse Voltage of Q2 = Vs

Q1 off, Q2 on, vo = -Vs/2

Waveforms with resistive load

Look at the output voltage

rms value of the output voltage, Vo

1
2

Vs
2 V
Vo
dt

2
To 0 4

To
2

2
s

Fourier Series of the instantaneous output


voltage
ao
vo an cos(nt ) bn sin(nt )
2 n 1
ao , an 0
0

Vs
1 Vs
bn
sin(nt )d (t ) sin(nt )d (t )
2
2
0

2Vs
bn
n 1,3,5,...
n

2Vs
vo
sin(nt )
n 1,3,5,.. n

rms value of the fundamental component

2Vs
vo
sin nt
n 1,3,5,.. n
1 2Vs
Vo1
2
Vo1 0.45Vs

When the load is highly inductive

Turn off Q1 at t = To/2


Current falls to 0 via D2, L, Vs/2 lower

+
Vs/2
+
Vs/2
-

Turn off Q2 at t = To
Current falls to 0 via D1, L, Vs/2 upper

+
Vs/2
+
Vs/2
-

Load Current for a highly inductive load

Transistors are only switched on for a quarter-cycle, or 90

Fourier Series of the output current for an


RL load

vo
vo
2Vs
io

sin(nt n )
2
2
Z R jn L n 1,3,5,... n R (n L)

n L
n tan (
)
R
1

Fundamental Output Power


In most cases, the useful power

Po1 Vo1 I o1 cos 1 I o21 R


2Vs

2 R ( L)

Po1

DC Supply Current
If the inverter is lossless, average power
absorbed by the load equals the average
power supplied by the dc source.
T

v (t )i (t )dt v (t )i (t )dt
s

For an inductive load, the current is


approximately sinusoidal and the fundamental
component of the output voltage supplies the
power to the load. Also, the dc supply voltage
remains essentially at Vs.

DC Supply Current (continued)


T

1
0 is (t )dt Vs

2Vo1 sin(t ) 2 I o sin(t 1 )dt I s

Vo1
Is
I o cos(1 )
Vs

Performance Parameters
Harmonic factor of the nth harmonic (HFn)

Von
HFn
Vo1

for n>1

Von = rms value of the nth harmonic component


V01 = rms value of the fundamental component

Performance Parameters (continued)


Total Harmonic Distortion (THD)
Measures the closeness in shape between a
waveform and its fundamental component

1
2
THD
( Von )
Vo1 n 2,3,...

1
2

Performance Parameters (continued)


Distortion Factor (DF)
Indicates the amount of HD that remains in a
particular waveform after the harmonics have
been subjected to second-order attenuation.

1
DF

Vo1

Von

2
n 2,3,... n

Von
DFn
Vo1n 2

for n>1

1
2

Performance Parameters (continued)


Lowest order harmonic (LOH)
The harmonic component whose
frequency is closest to the fundamental,
and its amplitude is greater than or equal
to 3% of the amplitude of the fundamental
component.

Single-phase full-bridge inverter

Operational Details

Consists of 4 choppers and a 3-wire DC source


Q1-Q2 and Q3-Q4 switched on and off alternately
Need to isolate the gate signal for Q1 and Q3 (upper)
Each pair provide opposite polarity of Vsacross the load

Q1-Q2 on, Q3-Q4 off, vo = Vs

+ Vs -

Q3-Q4 on, Q1-Q2 off, vo = -Vs

- Vs +

When the load is highly inductive


Turn Q1-Q2 off Q3-Q4 off

Turn Q3-Q4 off Q1-Q2 off

Load current for a highly inductive load

Example 6.3 MultiSim7

C1
1000uF

Q1
1V0V

XFG1

C2
1000uF

Q4
1V0V

D1
DIODE_VIRTUAL

10 Ohm

31.5mH

D4
DIODE_VIRTUAL

D3
DIODE_VIRTUAL

Q3
1V0V

D2
DIODE_VIRTUAL

Q2
1V0V

C
112uF

Example 6.3 using the scope


XSC1
G

C1
1000uF

Vs
220 V

Q1
1V0V

XFG1

D1
DIODE_VIRTUAL

Rs
1 Ohm

C2
1000uF

Q4
1V0V

D3
DIODE_VIRTUAL

Q3
1V0V

D2
DIODE_VIRTUAL

Q2
1V0V

9 Ohm 31.5mH 112uF

D4
DIODE_VIRTUAL