Closed Conduit Measurement Techniques: Monroe L. Weber-Shirk S Civil Environmental Engineering
Closed Conduit Measurement Techniques: Monroe L. Weber-Shirk S Civil Environmental Engineering
Techniques
Monroe L. Weber-Shirk
Measurement Techniques
Direct Volume or
Weight measurements
Velocity-Area
Integration
Pressure differential
Pitot Tube
Venturi Meter
Orifice
Elbow Meter
Electromagnetic Flow
Meter
Turbine Flow Meter
Vortex Flow Meter
Displacement Meter
Acoustic Doppler
Laser Doppler
Particle Tracking
Measure
Stream flow
Pitot
Tube
Integration
Venturi Meter
1797
z1
z 2 hL
2g
2g
Yes!
Bernoulli equation applicable?_______
2g 2g
D2
p1 p2 V22
2 g
D1
V2
2 g ( p1 p2 )
1 D2 D1 4
Q Cv A2
V1 D12 V2 D22
2 g ( p1 p2 )
1 D2 D1 4
Q K venturi A2 2 gh
Orifice
8D
2.5 D
h
Q K orifice Aorifice 2 gh
Q K orifice Aorifice
2p
Elbow Meter
Centripetal force at the bend
results in higher pressure at
the outside of the bend
Any elbow can be used as the
meter
Needs to be calibrated (no
standard calibration curves
are available)
V2
Fc m
r
?
Q =K elbow Aelbow 2 g Dh
magnet
conductive fluid
electrodes
measure voltage here
nd
S
V0
Displacement Meter
Used
Orifice Example
Estimate the orifice diameter that will result in a 100 kPa
pressure drop in a 6.35 mm I.D. pipe with a flow rate of 80
mL/s. The orifice coefficient (Korifice) is 0.6.
What is the ratio of orifice diameter to pipe diameter?
If the smallest pressure differential that can accurately be
measured with the pressure sensor is 1 kPa, what is the
smallest flow that can accurately be measured using this
orifice?
What are two ways of extending the range of measurement
to lower flows?
Fdoppler = -Fsource ( V / C )
Point measurement
_______
_______ measurement
Point
http://www.tsi.com/
http://amy.me.tufts.edu/
Questions to Ponder
Will
Orifice Solution
Estimate
d=
4Q
p K orifice
2 Dp
r
2p
d=
p d 2 2 Dp
Q =K orifice
4
r
4 ( 80 10 - 6 m3 / s )
p ( 0.6)
2 ( 100000 Pa )
1000kg / m3
d =3.46mm
Orifice Solution
What is the ratio of orifice diameter to pipe
diameter? (0.546)
If the smallest pressure differential that can
accurately be measured with the pressure sensor is 1
kPa, what is the smallest flow that can accurately be
measured using this orifice?
p d 2 2 Dp
Q =K orifice
4
r
8 mL/s