Process Communication Unit PCU400 MR9
2001-01/SPIDER MR 9
PCU400
Process
Communication Unit
PCU 400 Product Presentation
ABB Utilities - 2 -
PCU 400 Presentation Agenda
History
Protocols
PCU 400 concept and configuration
Documentation
Data flows
Tools
Ordering
H/W
ABB Utilities - 3 -
PCU 400 Requirements for the product
SPIDER rel. SPIDER rel. 7 SPIDER rel. 8 SPIDER rel. 9 SPIDER rel.
1 10
Front-End 200
RCS210
RCS300
DCU PCU400
Release 1 Release 3
ABB Utilities - 5 -
PCU400 implementation:
ABB Norwegian User Convention
Configurable link address and Common address
Handling of Integrated Totals considered spontaneous transmission from
the RTU (i.e. ASDU 101 not used)
File transfer is still not supported but will be developed
LAN or WAN
RSP Links
PCU400 A PCU400 B
ABB Utilities - 9 -
RTU lines
PCU 400 as Front-End
Application
Servers
Functions:
Front-End for SPIDER or SCADA Router
RSP protocol to SPIDER
WAN
Downline loading of DB from SPIDER
Router
124 multi-drop lines to RTUs Can be distributed
RSP protocol over
Ethernet or RS-232
Protocol configurable per line over WAN
PCU 400
Various communication media
Replaces RCS300 (not all protocols supported)
Available RTU protocols
Distributed configuration is supported
ABB Utilities - 10 -
RTU or
NG ZG
WT
15 1
SCS system
PCU 400 as Concentrator for SA and SCADA
Remote Master Systems
Functions:
Data concentrator
Multiple multi-drop lines to RTUs / IEDs F.ex. IEC870-5-101
Multiple lines (1-24) to Master systems
Protocol configurable per line
Media converter
Local configuration
Allow connection to old systems
Configuration Tool
NG ZG
WT
15 1
NG
15 1
ZG
WT RTU or
Protection relay
ABB Utilities - 11 -
PCU 400 as Converter
Remote
Functions: Master System
Configuration Tool
F.ex. Indactic 2033
NG
15 1
ZG
WT RTU or
SA system
ABB Utilities - 12 -
PCU 400 Functionality
IEC870-5-101
Redundant lines individually configurable
Dial-up is supported and separated from the protocol
Dual-LAN
External minute pulse
Bit-protocol support
FTAB-loading RP570/571
Remote diagnostics via Telnet
File transfer is not supported in PCU400 and RCS300
DNP 3.0 is not supported yet
ABB Utilities - 13 -
Aftersales opportunities
NG ZG
WT
15 1
PCU 400 Data flow - Gateway
Customer data
XML-files
LON
Configuration Tool
ABB Utilities - 20 -
Excel based
Event list
Logging
Device status
ABB Utilities - 21 -
PCU 400 Development tool
Standard software
Microsoft Development Studio 6.0
Language C and C++
Visual Source Safe
PC based
portable for site assistance
ABB Utilities - 22 -
PCU 400 Hardware
Standard PC type
Communication cards
Standard COM-ports for asynchronous byte protocols. Speeds up to
56kbps/line
OCC-card 8ch for bit and byte protocols (used in standard config.)
Speeds up to 9.6kbps/line.
Qualifying card is the RCS320 BCOM56-PCI Speeds up to 56kbps
1-24 lines i.e. 3 OCC cards in one PC
Developed as eXternal-modules.
No interference with other system components
Private database structures
Template as a base for new protocols available for:
RSP interface
API for internal functions
Media and Low level drivers available
Or use DDE protocol interface. This will gain access to many
already developed protocols.
ABB Utilities - 24 -
Customer benefits
PCU400 is flexible
Different configurations are supported
Standard non-ABB hardware is used
Standard Windows NT 4.0
Open interfaces available e.g. DDE, XML
Protocols can be bought as 3rd part products e.g. LON
Protocols are run as separate processes in NT
Remote diagnostics via LAN or Modem
Adds functionality as new protocols to old systems
ABB Utilities - 25 -
Customer benefits (cont.)
On-site:
BKK project in Norway
22 pcs PCU 400 in operation since 14th of June 1999
Operational hours per PCU is 8800 hours
Total operational hours is 190 000 hours with no H/W failure
Tussa Kraft, Oppland Energi, Nord Trondelag 1999
Current Projects:
SCECO (Saudi) 8 pcs PCU400 with Indactic 33 & RP570
ABB SWG in Untra, Panama & Kolsva IEC870,DNP+LON
Schneider-Electro, Sweden ADLP180-MODBUS
ABB Utilities - 27 -