Smart

Heating

Installation Guide
Raon Floor Heating Mat

Help Line
Tel. 5541-4895
Fax. 5547-3405
bestlife125@gmail.com
www.bestlife.mx
Contents

Simple steps to Luxurious Heating

Configuration Note

Calculating the actual spacing of

the heating element on the floor

Technical Specification

Dos & Don'ts


Simple steps to Luxurious Heating

Clean up the floor Mark the floor to be area


heated

Spread the heating mat on the floor and cut the mat only not heating cable

After cutting, change direction and spread mat on the floor


Fix the mat on the floor

Earth Wire (green)


Cold Lead Wire(2M)

End Point
Electric power cable

Testing (fault, Tiling


resistant)

Connect the thermal


controller
Wiring Configuration Note (Single conductor)

While the installation instructions only make provision for the heating elements to
be installed in a set configuration, there are many instances where departure from
this configurations may be desirable. Below are a few drawings illustrating such
instances:

In each of the above examples, the floor space is heated using different wire
configurations to suit the particular layout of the room. Most layouts will differ with
every job.
Calculating the actual spacing of the heating
element on the floor

1. Work out the sqm to be heated (see grey shaded area)


ex)4.9

2. Divide this figure by the length of the wire to be used per the sizing guide

4.9 / 56m of wire = 0.0875

3. Multiply this figure by : 0.0875 * 1000 = 87.5mm

Summary
4.9 / 56m of wire = 0.0875 * 1000 = 87.5mm apart

<Helpful Hints>

The element is a continuous wire that must not be shortened or lengthened


Even spacing of the wire will ensure an even temperature of your tiles
For a successful long install life, your floor should be clean, dry and stable
(wooden floors) or fully cured (concrete floor)
Technical Specification

Your HTR FH heating element is one


Cable construction Double Conductors continuous resistance wire with
Conductor electrical conducting wires connected
PTFE
insulation to each other

Second insulation XHDPE It must not be cut shortened or


lengthened
Sheath Thin Aluminum braid Once the heater has been installed,
Outer jacket XHDPE
avoid all traffic over the heating
element until the floor has been tiled
Rated Voltage 220V (Max.250V)

Installed output 21W/M(Max.35W/M)


HTR Floor heating system
Using temperature -30 ~ 20 has Obtained certificate of
CE
HTR Floor heating system
is for 210VAC and 260VAC

Mat
Product Output Wide Weight Voltage
Model length
Name (Wattage) (M) (Kg) (Max)
(M)

RFHM200-13M2V 260 0.45 3 2 220(250)


RFHM200-25M2V 520 0.45 6 3
Raon
Heating RFHM200-50M2V 1023 0.45 12 5.6
Mat
RFHM200-75M2V 1510 0.45 18 9
RFHM200-100M2V 2020 0.45 24 11
Installation Finish Section
Dos & Donts

Dos
Ensure a smooth, clean and dry surface before beginning installation
Plan the wire layout and stick to recommended wire spacing and perimeters
Plan post-tiling drilling (for fixing sanitary ware, door steps) so as not to damage the
wiring
Maintain a gap between wire runs of at least 50mm at all times
Make sure that all the element wire is positioned under the tiles in the installation
Check that the heater is working before commencing tiling
Take particular care when tiling not to dislodge or damage the heater element
Ensure that each tile is solidly bedded in the adhesive, with no gaps or voids

Donts

Dont cut or attempt to shorten the element wire at any time


Dont commence installation on a concrete floor that has not fully cured
Dont allow traffic over the installed heater before tiling
Dont allow the wires to cross over or touch each other at any point
Dont store tiles or sharp or heavy objects on the wiring whilst tiling
Dont switch on the heater until the adhesive has fully cured(7days)