(KSAR BOUKHARI, BERROUAGHIA) et (Mesaad)


(W1560,W1083 & W1520)

15 Mars 2017
Point W1516 MS1 kasr elboukhari
The drop is caused by soudden bad radio condition

rong azimuth of UME2614 S2 and S1 is suspected (We need to know the azimuth of
all sectors on site )
2 3/20/17 Drive test RN Mila_Constantine
Point W1516 MS2 kasr elboukhari
Low throughput is due bad radio condition

rong azimuth of UME2614 S2 is suspected (We need to know the azimuth of all
sectors on site ) and it i recomended to change eulServingCellUsersAdmTti2 from 4 to
30 and Eularget from 128 to 256
3 3/20/17 Name Presentation
Point W1083 MS2 mesaad
After drive test analyze and check the performance of the site the only suspected cause of low EUL throughput
is High UL interfrence during the test.

It is recomened to change EULtarget from 128 to 256 and eulServingCellUsersAdmTti2 from 4 to 30


to improve EUL throughput and to try with CPICH 340 to improve the radio condition
4 3/20/17 Name Presentation
Point W1520 BERROUAGHIA
Wrong logfile

I Will contact Salim to get the good log.