RET calibration
RET PROBLEM
Description :
There is a mismatch between the real value of RET on sit
e and the scan value on RNC
Cause:
the RET was modified on site manually and not using the
adequate tools antenna controller
Solution:
Recalibrate all the RET value with RNC
Needs :
site engineer and RNC engineer with high collaboration
Procedure for Andrew anten
na
1. Get the information of SN of RET for each band (GSM
,DCS and 3G) of antenna for each Sector and the tilt v
alue (site work)
2. Configure the RET on RNC side and set all the value t
o 0 (RNC work)
3. Remove the RET and set the tilt to 0 manually and rei
nstall the RET (site work)
4. test the RET by moving the tilt up and down (RNC sid
e)
5. Check if the RET is moving and the value is the same i
n both side
6. Change back the value of the tilt to the initial value o
n site (RNC work)
7. Check if the RET is set back to initial value (site work)
Procedure for ARGUS antenna
1. Get the information of SN of antenna for
each Sector and the tilt value (site
work)
2. test the RET by moving the tilt up and
down (RNC side)
3. Check if the RET is moving and the
value is the same in both side
4. Change back the value of the tilt to the
initial value on site (RNC work)
5. Check if the RET is set back to initial
value (site work)
TMA proble
m
Since the 2 TMA of sector 2 and 3 are connected to
the same RSU 82 we can not distinguish between t
he 2 TMA when scanning them from
for this reason the SN should be taken on site so
we can configure the TMA correctly
Thanks!