Nemo Outdoor User Training

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 51

Nemo Outdoor User Training

Nemo User Training


Course Contents
Nemo Outdoor_Indoor Basic Installation
Hardware Configuration
Nemo Outdoor Measurement Configuration
Introduction to Graphical User Interface
Nemo Outdoor Playback & File Formats
Nemo Outdoor_Indoor Installation

- Nemo Outdoor_Indoor License Option


- Basic SW Installation
Copy Protection
Nemo Outdoor uses either software or hardware
protection. (Indoor and Outdoor measurement are
restricted by dongle options)
Various available options are configured with each
copy protection module.
Nemo Outdoor/Indoor Installation

Installation:

You need to have local Administrator rights to install Nemo Outdoor

Run the Nemo Outdoor setup.exe file and follow the instructions. Current Nemo
Outdoor SW is 4.20.73 Check the latest versions of Nemo software from our
web pages at (www.nemotechnologies.com) Valid to users with Technical
Support Agreement only.

Install DKU 2 cable driver.

Restart laptop
HARDWARE SETUP
Testing Concept Voice Call

The voice testing


environment consists of
Nemo Outdoor
compatible test
measurement mobiles
Laptop/Tablet PC with
Nemo Outdoor
installed
Necessary connecting
cables
GPS receiver for
Outdoor measurement
(optional) fast
frequency scanner.
Testing Concept PS Data Call
The PS data testing
environment consists
of Nemo Outdoor
Application
Server(e.g. FTP
server, HTTP server,
POP3 server, SMTP
server, or WAP
server)
Nemo Outdoor Measurement Configuration
Manual / Automated Mode

Nemo Outdoor supports manual and automated mode.


Manual mode is based on the user establishing a data transfer connection or
making voice calls.
- This mode is useful, when user wants to make a single continuous data
transfer session or a voice call to monitor the resource allocation and cell
reselection performance.
- This mode requires the user to control phones with Nemo Outdoor. The user
should NOT use the mobile keyboard to establish voice calls or data calls.
Automated mode is based on scripts that establish data transfer connections or
voice calls on behalf of the user and can repeat the same or different sessions for a
defined period of time. Scripts can be saved and edited. Script files can be, quickly
and easily built with the Script Editor.
Introduction to Graphical User Interface

Device Info
Configuration:
Device Info:
( )view disp parameters
( )define displayed parameters
( )configure notifications
( )control phone
( )configure measurement
parameters
Measurement Properties

Measurement properties for


Voice Calls, Data calls etc.
Need to be defined before the
actual measurement
Manual Measurement Configuration

Information on this tab should be filled in when doing


Manual Measurement. (Press Properties)
Voice Number defines the phone number to which
voice calls will be made.
Data Number defines the phone number for data
calls, user name and password for service, etc.
PDP Context Properties defines used APN for Packet
data connection
Data Protocol defines whether FTP or UDP is used
for data transfer
ICMP Ping Properties defines Ping settings, like Ping
address and size of Ping data
Manual Measurement Control

Measurement can be done from Mobiles


Control Panel or from Measurement menu
by selecting the appropriate mobile
Automatic Measurement
Measurements can be automatically repeated by predefined number of times
Voice calls, data calls, attach, PDP activation, FTP, Web browsing, SMS, MMS, launch of
external application, Ping sessions, etc. can be included in automatic measurement sequence
Add / Modify / Delete / Move up / Move down / Append script / Repeat script value/
New /Open / Save / Save As...
Voice Call Script Configuration

Script Editor/ Add / Voice Call


Voice Call Properties
Number defines the
number to be called
Call Duration determines
the time that the call lasts
in seconds
Call Attempt Timeout value
determines the maximum
duration of the call
attempt. After that, the
call attempt is considered
to be failed.
PS Script Configuration

Application Testing

Access Point Name


defines the APN used
User Name/Password etc.
Depend on operators
settings
PS Script Configuration

Host Name: IP address of the FTP server


used.
Username: username for the FTP server.
Password: password for the FTP server.
Passive Mode: Some firewalls may be
configured to refuse any incoming
connection requests, and in that case the
data transfer would fail. With passive
mode, the client always opens those new
connections so the firewall does not block
the connection.
Direction: Receive downloading; Send
uploading
Remote File: File @ FTP Server
Local File: File @ Testing laptop
PS Script Configuration

URL: IP address of the test file that will


be downloaded. For example,
203.125.58.120/1000kb.htm

Local File: File @ Testing laptop


Script Configuration

Editing PS Script
Ping Test
The ICMP (Internet
Control Message Protocol)
Ping functionality allows
you to perform ping
measurements
simultaneously with FTP
testing and data transfers
Script Enhancements

Possibility to synchronize scripts


repeats between devices for
benchmarking measurements.

Improved wait function allows


waiting for notifications during
script measurements.

Option to use measurement


settings configured for manual
testing during script measurements.
Event Trigger Notifications

By clicking the Notifications sheet, you


can access the Notifications dialog box

Select the Events that you would like to


be notified of and also select whether the
notification will be a textual note in the
Output window, a sound (.wav file), or a
bitmap

Own notifications can be created for


different situations, like bad quality
example below, in Configuration tool
User Defined Event Trigger Configuration I

Static triggers
Static triggers are made available in
Nemo Outdoor by default and can
collect statistics.
User configurable event trigger
User Defined Event Trigger Configuration II

Bitmap image Audio Wave Notification


Event Trigger Configuration

Event bitmap
displayed in map
window

Event bitmap
displayed in line
graph

(1.) Textual Notification (2.) Sound Notification


displayed in the Output window
Real-time monitoring during measurement
Real-time monitoring during measurement
Introduction to Nemo Outdoor
Graphical User Interface
Introduction to Graphical User Interface
Introduction to Graphical User Interface

Script Status
window

Output window
Status bar
Introduction to Graphical User Interface

Windows: Graphs

Line Graphs allow the user to accurately observe the measurement information.

zoom
thresholds
scale
selectable parameters & values
selectable layers & values
average value presentation
displaying events & notifications
Workspace and Hardware Configuration

By saving the workspace, different views can be saved to a .wor file. The following
views are saved to the file:
Device Information Window views
Grid and Graph views
Color Set and Parameter selected in the Map Window (Map layers must be saved
to MapInfo .gst file)
By saving the hardware configuration file, the information related to device(s) is
saved to the .hwc file:
All information defined in the Measurement Properties Window
Introduction to Graphical User Interface

Windows: Graphs

Line graph Bar graph


Introduction to Graphical User Interface

Windows: Graphs Scatter plot

Scanning results
Introduction to Graphical User Interface

Windows: Grids

The user can easily select the events, parameters, and statistics to be
displayed in the grid table. It is also possible to highlight certain events
with color to improve the clarity of the results presented. Double-click on
an event to view more information about that particular event.
Introduction to Graphical User Interface
Windows: Grids
Parameters
Events
Introduction to Graphical User Interface

Windows: Grids
Layer
3

Statistics

Decoded Layer3
Introduction to Graphical User Interface

Textual Windows: Grids Graphical Windows: Graphs


Statistics
Scatter plot Line graph
Decoded Layer3
Parameters Scanning Plots
Events
Layer Bar graph
Table
3
Nemo Indoor & Floor plan

Nemo Indoor
supports indoor
floor plan in .tab;
.bmp; .jpg; .tif
formats.
Nemo Indoor & Floor plan
During
measurement,
markers( ) need
to be inserted in
order to plot
route on floor
plan.
Nemo Indoor & Floor plan

Indoor floor plan


properties
Nemo Outdoor and MS BTS File
Multiple Real-time Route Coloring

A line from the test vehicle to the


serving and neighboring BTS can
be drawn.
New multi route feature allows users to compare easily
measurements from different terminals on the same map or to
correlate different parameters from the same terminal.
Playback in Nemo Outdoor

The Play button starts the playback

The Pause button pauses the playback

The Stop button stops the playback

Add Marker

Add Textual Note

Playback Speed
Files Used by Nemo Outdoor
Files Used by Nemo Outdoor

Workspace files
BTS files
.wor
.bts, .nbf
Hardware configuration files
MAP files
.hwc
MapInfo vector and raster maps
Script files
Result files
.nsf
.dt1, .dt2, .dt3, .dt4
.fs1, fs1, fsn
.ft1, ft2, ftn
Nemo Outdoor Measurement File
With Call mode measurements, *.DT1 file is produced.

With Frequency/Pilot Scan (Separate Scanner) measurements , *.FS


file is produced.

Open ASCII non-proprietary file format

Easy to view and use


Nemo Outdoor Measurement File Contents
Field strength results of the serving and neighbouring cells

Quality class values

Mobile output power level

Layer 3, layer 2, RLC/MAC, LLC and RRC messages

Geographical coordinates and time

Call events and handover events

Location update events

Channel information

Other information
Example of Nemo Outdoor Measurement File header
*** Nemo Outdoor 4.12.22 ff ver 1.72 28.01.2004 11:47:41
#ID Id tag for simultaneous measurement files : {342E0B9C-E2B5-495e-97AC-87D2B710A166}
#AG External antenna gain (dBi) : 0.00
#BF BTS filename :
#CF Call list filename : d:\Nemo Tools\deactivate.nsf
#CL External cable loss : 0.00
#CM Call mode : Originate
#HV Handler version : 4.01.12
#MF Map filename :
#MT Mobile type : T260
#NN Network name :
#NT Network type : GSM 900/GSM 1800
#PN Test call phone number :
#SW Device software version : af.7f.cb
#HW Device hardware version : 4C7
GAA 0.000000 0.000000 0 0 0 0 0 11:47:42.827
GAC 0.000000 0.000000 0 0 0 0 0 11:47:42.827 8
LUA 0.000000 0.000000 0 0 0 0 0 11:47:42.827
Questions?
THANK YOU!

You might also like