Section 11: Appendix: Equipment Architecture

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 18

Section 11

Appendix: Equipment Architecture

NORTEL NETWORKS CONFIDENTIAL


BSC Fully Equipped Cabinets
Control Equipment

+5V, 100A 2 3 4 5 10 11 12 13 18 19 20 21
5V PSUE
+12V, 4A PSUC
-12V, 3A D D D D D D D D D D D D
12A EQPD1
D
T
D D D D D D D D
T T T T T T T T
D D D
T T T 5V shelf
FANS
I I I I I I I I I I I I 12A
0 1 22 23 6 7 8 9 14 15 16 17
0 1 0 0 1 2 3 2 4 5V PSUE
M C C C S C S S S S S C S C C S
MPUA D D D D D D D D D D D D
12A EQPD0
M C C P I P I U L I I P I P C I
U S S U C U C P S C C U C U S C
shelf
D
T
D
T
D
T
D
T
D D D D D
T T T T T
D D D
T T T 5V shelf
7 7 O D E D X D E D E 7 D
M 8 8 8 8 8 I I I I I I I I I I I I 12A
U
0A 1A 2A 3A 4A 0 1 0B 1B 2B 3B 4B
5V PSUE
FANS
A R R R R R T T R R R R R
12A EQPI
+5V, 100A
L C C C C C S
A B B B B B C
S C C C C C
C B B B B B 5V shelf
+12V, 4A PSUC B B 12A
-12V, 3A
FAN FAN FAN
FANS

0 1 0 0 1 2 3 2 4 1A 1A 0A 0A A A B B 0B 0B 1B 1B 5V PSUE
12A SWG
M C C C
M C C P
S
I
C
P
S
I
S S S S
U L I I
C
P
S
I
C
P
C
C
S
I MPUB S M M S S E E S S M M S
U S S U
7 7 O
C
D
U
E
C
D
P S C C
X D
U
E
C
D
U S
7
C
D shelf W S S WW C C W W S S W
E W W E C I I C E W W E
5V 5V shelf
E
M 8 8 8 8 8 12A 12A
U
B B B B B
B B B B B B B
FANS S S S S S
S S S S S S S PSUE PSUE
C
B
C
B
C
B
C
B
C
C
B
B
C
B
C
B
C
B
C
B
C
B
C
B
EQPT
1
2 3 4 5 6 7 8 9 0
1
1
1
2
1
3 PSUE
shelf

FAN FAN FAN

NORTEL NETWORKS CONFIDENTIAL 2


BSC 12000 Architecture
To/From OMC-R
C
O MMU SLS MPU MPU SLS
Chain A MMU
N Status Ethernet Status Chain B
T
R CPU- CPU- CPU- CPU- CPU- CPU-
OMU MPU BIFP Inter SUP
O BIFP MPU OMU Multibus II
SUP SUP
L
Multibus II MPUA SIC SIC MPUB
SICX CCS7 D8V D8V CCS7 SICX

V11 64 kb/s V11 64 kb/s

E
ECI A SWC RCB RCB ECI B
Q SWC
U MSW-SWE MSW-SWE
I
Internal PCM/A Internal PCM/B
P
M
E MPU MPU
N Status Status
T ALA TSCB BSCB DDTI
O&M/A bus O&M/B bus

External Loops To/From BTS To/From TCU/MSC


NORTEL NETWORKS CONFIDENTIAL 3
BSC 12000HC Architecture
To/From OMC-R
C
O MMU SLS2 MPU MMU
MPU SLS2
N IDE Chain A Status Ethernet Status Chain B IDE
T
R CPU- CPU- CPU- CPU- CPU- CPU-
OMU MPU BIFP Inter SUP
O BIFP MPU OMU Multibus II
SUP2 SUP2
L
Multibus II MPUA SIC SIC MPUB
SICX CCS7 D8V D8V CCS7 SICX

V11 64 kb/s V11 64 kb/s

E
ECI A SWC RCB RCB ECI B
Q SWC
U MSW-SWE MSW-SWE
I
Internal PCM/A Internal PCM/B
P
M
E MPU MPU
N Status Status
T ALA TSCB BSCB DDTI
O&M/A bus O&M/B bus

External Loops To/From BTS To/From TCU/MSC


NORTEL NETWORKS CONFIDENTIAL 4
TCU Fully Equipped Cabinet
T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU0 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5

T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C 2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU1 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5

T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU2 5V/12A 5V/12A 5V/12A
1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5

T T T T T T T T T T T T T T 5V/12A 5V/12A
C C C C C C C C C C D D D U
B B B B B B B B B B T T T C
2 3
2 2 2 2 2 2 2 2 2 2 I I I
TCU3 5V/12A 5V/12A 5V/12A

1 5 9 13 17 21 25 29 33 37 41 45 49 53 1 4 5

NORTEL NETWORKS CONFIDENTIAL 5


BSC e3 and TCU e3 Physical Presentation

BSC e3 TCU e3
Power Supplies

Fans

Service Service
Area Control Transcoding
Area
Interface Node Node
Interface
(PCM cabling) (PCM cabling)

Fans

Interface Transcoding
Node Node

NORTEL NETWORKS CONFIDENTIAL 6


Node
Control
BSCe3: Control Node

Shelf 0
Shelf 1

1
1

TMU TMU
2

2
- Filler
TMU- - Filler
TMU-

NORTEL NETWORKS CONFIDENTIAL


3

TMU TMU
4

TMU TMU
5

MMS Private
OMU
6

MMS Shared
7

- Filler - ATM SW
8
8

- Filler - ATM SW
MMS Shared
OMU
MMS Private
TMU TMU
TMU TMU
7

TMU TMU
TMU TMU
9 10 11 12 13 14 15

9 10 11 12 13 14 15

SIM A SIM B
BSCe3: Interface Node

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

1 2 3
LSA LSA LSA

- Filler -

- Filler -
- Filler -
Shelf 1 RC RC RC

SIM A
ATM RM
ATM RM
5 0 4
Shelf 0 LSA LSA LSA

- Filler -
RC RC RC

8k RM
8k RM
CEM 0
CEM 1

SIM B
Interface
Node

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mandatory
for
synchronization
NORTEL NETWORKS CONFIDENTIAL 8
TCUe3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

1 2 3
Shelf 1 LSA T T LSA LSA T S
RC RC RC

Filler

Filler
R R R I
Transcoding M M M M
Node

0 C C
Shelf 0
T T T LSA E E T T T T T T S
RC M M R R R R R R I
R R R
0 1
M M M M M M M M M M
Transcoding
Node

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Mandatory
for
synchronization

NORTEL NETWORKS CONFIDENTIAL 9


S8000 Outdoor BTS

CBCF
(or BCF)

RECAL
(or ALCO)
AC BOX
PA

DRX
F-type
Converters RX-SPLITTER
Battery switch
RF Combiners
PCU

Rectifiers

NORTEL NETWORKS CONFIDENTIAL 10


S8002 BTS

Cooling system CDACS

Rectifiers Power
interconnection
Power (CBCF, RECAL, User)
Controller
Unit

RX Splitters
DRX modules
Couplers
CBCF
Power Amplifiers
User compartment (6 U)
C-PA interconnection
(PA, RECAL, Main interconnection
F power supply, duplexer) (DRX, PA, CBCF, RECAL,
duplexer)
F type
C-AC Main Box
Power Supply
Batteries RECAL board

NORTEL NETWORKS CONFIDENTIAL 11


S12000 Indoor/Outdoor

NORTEL NETWORKS CONFIDENTIAL 12


BCF Architecture

Internal BCF
DRX Private PCM bus CSWM
GTW
P PCM Gateway CSWM PCMI
o To/
w PCMI from
e PCMI BSC
r PCM Interface

A DRX DRX Internal


Radio Logic PCM bus
m
p
l GSM
i Control DSC
Time and Signal.
f bus SYNC
Synchro.
Switching Concentr.
i Management
e
r
O&M bus

ALCO
Alarms
FH bus Concentration

NORTEL NETWORKS CONFIDENTIAL 13


Compact BCF Architecture

CBCF CMCF 2 Private PCM


Switch 8 DRX
CPCMI 6 Private PCM

RECAL

GSM
Time Private PCM
2 Private PCM
Idle Master Slave 8 DRX
Register Processor Processor

Synchro Data Bus RECAL


Function
Extension cabinet 0

Main cabinet
Extension Cabinet 1
2 Private PCM

NORTEL NETWORKS CONFIDENTIAL 14


S2000H BTS Physical Architecture
DRX Main PSU

Heaters

DRX SBCF
MAIN MODULE

BASE
UNIT I/O field I&C

UVGA 2 VGA

HPRF PSU HPRF POWER


SUPPLY MODULE (FP only)

MEU Protection PCB

Batteries, AC BATTERY & INTERFACE


and TELCO Modules MODULE

NORTEL NETWORKS CONFIDENTIAL 15


S2000L BTS Functional Architecture
Abis Interface for BSC/Drop&insert BTS

SBCF
PCM
management

Abis Abis
OML PCM
RSL synchro

External alarms Configuration Software Synchronization


and management management
supervision
External outputs management
Commissioning
& Maintenance Test
Test Interface I&C Terminal management
User Interface
for Test Installation
SBCF/DRX GSM
protocol time
DRX
Software RSL Test
management management management

Radio
Configurations Interface
Synchronization Radio
Supervision
management management
management

NORTEL NETWORKS CONFIDENTIAL 16


SBCF Architecture

SBCF SMCF DRX


DRX
SPCMI
Switching
Matrix Internal
Internal PCM bus
Frame PCM bus DRX DRX
External Aligner PCM Logic Radio
PCM interface
(ABIS (V11)
interface)
Private
PCM

Main bus FH bus


Control
FPGA Unit Debug
(QUICC
Synchronization DRAM
I&C SBCF and Flash)
Terminal GSM time
Ethernet

ALCO 2 driven
Alarms contacts
6 ext alarms Concentration
Temp.
Sensor

NORTEL NETWORKS CONFIDENTIAL 17


NORTEL NETWORKS CONFIDENTIAL

You might also like