Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 1

Twisted pair shielded cable to be used to connect

the machine.(cable length up to 2000 Mtrs)


7 +TX / +RX
5
RS 485/232 SIGNAL
6 -TX / -RX
6 CONVERTER

7 6 7 6

C
7 6 P
U

KBM UNIT 1
BBR UNIT 1 BBR UNIT 2
ID-3 ( UP TO 30 UNITS)
ID-1 ID-2

NOTE:
-THE RS485-RS232 CONVERTER, CABLE BETWEEN JUNCTION BOX AND CONVERTER
(2 MTR.), CABLE BETWEEN CONVERTER AND COMPUTER COM PORT (1 MTR.)
WILL BE SUPPLIED BY US.
-7/36 TWISTED PAIR SHIELDED CABLE MAY BE USED TO CONNECT ALL MACHINES
- THE CABLE FROM THE CONTROL PANEL SHOULD TERMINETED NEAR THE COMPUTER (CPU UNIT)
--THE CABLE WIRING IS EXPLAINED AS ABOVE.
-DIMENSION OF CONVERTER BOX IS: (W) 110mm x (D) 100 mm x (H) 50 mm.
-IF MORE THAN ONE UNIT IS TO BE CONNECTED THEN CONNECT ALL UNITS PARALLAL TO EACH OTHER VIA
25 PIN D TYPE CONNECTORS PIN 6 TO EACH OTHER AND
ALSO PIN 7 TO EACH OTHER.(UP TO 30 UNITS CAN BE CONNECTED AS SHOWN IN ABOVE DIGRAM WITH THIS SOFTWARE)
EACH UNIT IS IDENTIFIED BY ITS UNIQUE ID NO. ON ITS DIGITAL DISPLAY.

Wiring digram for data-soft communication.