Professional Documents
Culture Documents
UW Goesgen Protection Concept: Technology and Solutions
UW Goesgen Protection Concept: Technology and Solutions
Protection
Technology and Solutions
Protection and Substation Automation
Concept
REB500
ABB Switzerland Ltd. - 1
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
Current Situation
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 2
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA02 -Q1 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 3
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA02 -Q2 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 4
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA02 -Q0 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
Measurement active for both
zones
ABB Switzerland Ltd. - 5
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA0X Q62 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Measurement
blocked because
Q9
of Breaker
Open
Diff. Protection Busbar A is automatically blocked
As feeder current ACA0X is not measured
ABB Switzerland Ltd. - 6
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA0X Q0 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA0X Q9 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour without CT Remote Station
ACA0X Q9 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour with CT Remote Station
Situation
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
Max. Distance
approx.1.2 km
ABB Switzerland Ltd. - 10
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
Line protected by
ABB
REB500 Diff. Protection
REB500 behaviour with CT Remote Station
ACA02 -Q1 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 11
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour with CT Remote Station
ACA02 -Q2 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
Measurement is blocked as related breaker is open
ABB Switzerland Ltd. - 12
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour with CT Remote Station
ACA02 -Q0 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
REB500 behaviour with CT Remote Station
ACA0X Q62 Closed
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Measurement
blocked because
Q9
of Breaker
bypass
ABB Switzerland Ltd. - 14
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
measured im remote station ACA0X.
REB500 behaviour with CT Remote Station
ACA0X Q0 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Measurement
blocked because
Q9
of Breaker
Open
ABB Switzerland Ltd. - 15
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
measured im remote station ACA0X.
REB500 behaviour with CT Remote Station
ACA0X Q9 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 16
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
measured im remote station ACA0X.
REB500 behaviour with CT Remote Station
ACA0X Q1 Open
A
B
Q2 Q1 Q62 Q2 Q1
Q0
Q9
ABB Switzerland Ltd. - 17
ACA02 ACA0X
Goesgen / 2003-02-12 /SJ
ABB
measured im remote station ACA0X.