[MODUL 01]

Eksperimen Fisika

Sistem Telemetri Radio


By:
Vicqy Bayu P. V. (10215004)
Daniel Suprobo W. (10215027)
Mohamad Reza Nurrahman (10215085)
Introduction
Purpose of this Experiment
Introduction What is Telemetry?
Introduction What is Telemetry?
Methodology
Percobaan Praktikum
Methodology
Percobaan Data Digital
Methodology
Percobaan Data Analog
Methodology
Percobaan Data Temperatur
Methodology
Percobaan Data Frekuensi
Methodology Pengambilan Data dari
Komputer
Data dan
Pengolahan Data Data Digital

RTU CTU
No. (Hex) (Hex) Error
% 1 4E 4E 0
2 4A 4A 0
= 100% 3 CA CA 0
4 D2 D2 0
5 DD DD 0
6 05 05 0
7 1D 1D 0
8 1C 1C 0
9 7C 7C 0
10 7B 7B 0
Jumlah Data Error 0
Error (%) 0
Data dan
Pengolahan Data Data Analog

.
=
= 2( ) (2 1)

() = . ()
1 =
2 1
= . (2 1) = | |

= (12)
= (2 1)

Data dan
Pengolahan Data Data Analog

Grafik V_RTU (V) terhadap V_CTU (DEC)

0.18
0.16 y = 0.0006x - 0.0007
R = 1
0.14 = 0.0006
0.12

V_RTU (V)
0.1 = 0.0007
0.08
0.06 = 2.457
0.04
0.02 1 = 0.0006
0
0 100 200 300
V_CTU (DEC)

= 0.0006 0.0007
Data dan
Pengolahan Data Data Analog

No. () () () () ()
1 0.036 03F 63 0.0378 0.0018 3.00
2 0.048 053 83 0.0498 0.0018 3.00
3 0.076 083 131 0.0786 0.0026 4.33
4 0.103 0B0 176 0.1056 0.0026 4.33
5 0.161 113 275 0.165 0.004 6.67
6 0.11 0BC 188 0.1128 0.0028 4.67
7 0.126 0D8 216 0.1296 0.0036 6.00
8 0.138 0EC 236 0.1416 0.0036 6.00
9 0.06 067 103 0.0618 0.0018 3.00
10 0.042 048 72 0.0432 0.0012 2.00
Data dan
Pengolahan Data Data Temperatur

.
=
2 1 . 10

= | |
Data dan
Pengolahan Data Data Temperatur


No. () () () () ()
Hubungan error terhadap data
1 29.12 1F1 497 29.82 0.7 pengiriman pada tabel 2
2 30.65 20B 523 31.38 0.73 1

3 31.58 217 535 32.1 0.52 0.8

0.6

()
4 32.11 224 548 32.88 0.77

5 33.52 23C 572 34.32 0.8 0.4


6 34.16 247 583 34.98 0.82 0.2
7 34.52 24D 589 35.34 0.82 0
8 34.75 251 593 35.58 0.83
0 10 20 30 40
_()
9 35.04 256 598 35.88 0.84

10 34.87 253 595 35.7 0.83


Data dan
Pengolahan Data Data Temperatur


No. () () () () ()
28.24 1E2 482 28.92 0.68 Hubungan error terhadap data pengiriman
1
pada tabel 3
30.24 204 516 30.96 0.72
2 1
30.65 20B 523 31.38 0.73
3 0.8
32.41 229 553 33.18 0.77
4
0.6

()
33.11 235 565 33.9 0.79
5
33.81 241 577 34.62 0.81 0.4
6
34.16 247 583 34.98 0.82 0.2
7
34.52 24D 589 35.34 0.82 0
8
0 10 20 30 40
34.87 253 595 35.7 0.83
9 _()
35.04 256 598 35.88 0.84
10
Data dan
Pengolahan Data Data Frekuensi

.
=
. 12. 106 ()


= ,
Keterangan :
= 0, , 127 = frekuensi kristal (11,059MHz)
= Jumlah data (128)
= Sampling time
= = Throughput


% = 100%

Pembahasan Analisis

1. Analisis kesalahan akibat transfer data input digital


melalui telemetri!
2. Jelaskan hubungan antar error LSB dengan besaran
dari nilai tegangan referensi!
3. Analisis kesalahan antara data temperatur yang
dibaca langsung dengan data suhu melalui
telemetri!
Pembahasan Analisis

4. Jelaskan tentang grafik frekuensi hasil percobaan!


5. Jelaskan cara mendapatkan harga frekuensi
dengan metode di atas! Bandingkan antara
frekuensi hasil pengukuran langsung dengan
hasil pengukuran melalui telemetri lalu
6. Adakah pengaruh jarak dan penghalang terhadap
tingkat ketelitian pengiriman data?
Pembahasan Pertanyaan

Berikan ulasan mengenai pentingnya sistem


telemetri di bidang industri dan penelitian, serta
keuntungan dan kelebihan sistem telemetri dengan
medium udara!
Conclusion