BITS Pilani

Comparative Analysis of different versions of


IS 1893 Part I

11/27/2017 1
Team Members
Amritanshu 2015A2PS0851P
Mayank 2015A2PS0840P
Akshay Patidar 2015A2PS0598P
Shubham Tripathi 2015A2PS0711P
Akash Singh 2015A2PS0857P

11/27/2017 2
BITS Pilani, Pilani Campus
IS 1893: Part I 2002 v/s 1984
No. of Seismic Zones
I and II incorporated together

Seismic Zone Factor Values

SEISMIC MICROZONATION

11/27/2017 3
BITS Pilani, Pilani Campus
MINIMUM DESIGN EARTHQUAKE
HORIZONTAL LATERAL FORCE BUILDINGS
( CLAUSE 7.5.1)
Buildings and portions there of shall
be designed and constructed, to
resist at least the effects of design
lateral force specified in 7.5.1. But,
regardless of design earthquake
forces, buildings shall have lateral
load resisting systems capable of
resisting a horizontal force not less
than P percent of the seismic weight
of the building as shown in Table.
This load may be applied at different
floor levels in proportion to the
seismic weight of respective floors.

11/27/2017 4
BITS Pilani, Pilani Campus
LATERAL ACCELERATION
FROM SERVICEABILITY CONSIDERATIONS, (HUMAN COMFORT)
UNDER STANDARD WIND LOADS WITH RETURN PERIOD OF 10
YEARS, THE MAXIMUM STRUCTURAL PEAK COMBINED LATERAL
ACCELERATION Amax IN THE BUILDING FOR ALONG AND ACROSS
WIND ACTIONS AT ANY FLOOR LEVEL SHALL NOT EXCEED VALUES
GIVEN IN TABLE, WITHOUT OR WITH THE USE OF WIND DAMPERS
IN THE BUILDING.

PERMISSIBLE PEAK
COMBINED ACCELERATION

11/27/2017 5
BITS Pilani, Pilani Campus
SLENDERNESS RATIO
The maximum values of the ratio of height H to minimum base
width shall not exceed values given below.

11/27/2017 6
BITS Pilani, Pilani Campus
PLAN ASPECT RATIO
The maximum plan aspect ratio of the overall building (L/B)
shall not exceed 5.0.

Building should be well-proportioned in


keeping with the known tenets of acceptable
upper limits of overall slenderness ratio and
plan aspect ratio, and all the discussions
available in earthquake design literature on
acceptable seismic structural configurations

11/27/2017 7
BITS Pilani, Pilani Campus
11/27/2017 8
BITS Pilani, Pilani Campus
Response reduction factor
Introduced in 2002 version
In place of performance factor
Based on material of construction
Ordinary RC shear walls-
Prohibited in zone IV, V.

11/27/2017 9
BITS Pilani, Pilani Campus
IS 1893- 2002 revision
Building Frame Systems- RC Frame, Steel
Frame
Building with Shear walls- Masonry, ORC,
Ductile
Buildings with Dual Systems- Ordinary, Ductile

11/27/2017 10
BITS Pilani, Pilani Campus
IS 1893- 2016 revision

Specified for all building system


Irrespective of material of construction
RC and Steel structure- Prohibited in zone III,
IV, V

11/27/2017 11
BITS Pilani, Pilani Campus
IS 1893- 2016 revision
Moment Frame Systems- RC, Steel
Braced Frame Systems- concentric, eccentric
Structural wall Systems- Masonry, ORC,
Ductile
Dual Systems- Ordinary, Ductile
Flat Slab- Structural Wall Systems

11/27/2017 12
BITS Pilani, Pilani Campus
Spectral acceleration
For 5% damping

11/27/2017
BITS Pilani, Pilani Campus
Spectral acceleration
For other damping values

This table is deleted in the revised version of


IS 1893 in 2016

11/27/2017 14
BITS Pilani, Pilani Campus
Importance factor

11/27/2017 15
BITS Pilani, Pilani Campus
A new value of Importance factor has been introduced
in IS 1893-(part-I) 2016.
Residential or commercial buildings or structures, with
occupancy more than 200 persons have been included
under importance factor of 1.2
This is the minimum value for which the building is to
be
designed. Other building which are not specified under
IS code may be designed for higher value of I.

11/27/2017 16
BITS Pilani, Pilani Campus
Weak Storey
It is one in which the storey lateral strength is less than that in
the storey above. The storey lateral strength is the total
strength of all seismic force resisting elements sharing the
lateral storey shear in the considered direction.
Earlier in 2002 version, for weak storey, the lateral strength
should be less than 80percent of the strength of the storey
just above it .

11/27/2017 17
BITSPilani, Pilani Campus
Soft Storey
It is one in which the lateral stiffness is less than that
in the storey above. The storey lateral stiffness is the
total stiffness of all seismic force resisting elements
resisting lateral earthquake shaking effects in the
considered direction.

11/27/2017 18
BITS Pilani, Pilani Campus
Most of the time, soft storey building is also the weak storey building.
In the 2016 version, these distinction has been made between soft and
weak storey.
Soft/weak storey buildings are well-known for poor performance during
earthquakes.
In Bhuj earthquake of 2001, most multistorey
buildings that collapsed had soft ground storey.

11/27/2017 19
BITSPilani, Pilani Campus
11/27/2017 20
BITSPilani, Pilani Campus
11/27/2017 21
BITSPilani, Pilani Campus
11/27/2017 22
BITSPilani, Pilani Campus