ERRU (Electronic Rectification and Regulating Unit)
ERRU (Electronic Rectification and Regulating Unit)
Dilpal Singh
Roll No 12
APP. JE
TL, DLI
Introduction
• ERRU stands for Electronic Rectifier cum Regulator Unit.
• The ERRUs 4.5 kW and 25 kW used in Indian Railway non-AC, AC
coaches receives the 3-phase AC voltage generated from a brushless
alternator.
• The output of the alternator is AC in nature with variable voltage and
variable frequency depending on the motion of the train.
• This AC voltage is rectified and passed through the controller to
generate regulated DC voltage as required for AC and non AC coaches.
Functions of ERRU
• Hall effect sensors are used for sensing the output load current and
battery charging current. The battery charging current is set to limit
the charging current as per the battery capacity.
DATA LOGGER WITH INTERFACE
• A four pin round type connector is provided for collecting data like
output voltage, current, battery current charging and discharging and
speed of the alternator from the regulator.
• Each regulator can be connected to down loading unit and the above
mentioned data can be downloaded at any time.
• Data for seven days are logged and stored in the memory and this can
be downloaded using the downloading unit.
EMERGENCY FIELD EXTENSION:
• The same data logger box contains the emergency field extension in
case of the failure of the control circuit of one regulator.
• As the voltage goes beyond 142 Volts for more than 3 seconds the
OVP circuit immediately reduces the field current and latches the
output voltage at less than 90 Volts. The latching remains even
without battery.
PERIODICAL MAINTENANCE INSTRUCTION FOR ERRU
• Check all the connections are tight. If found any loose connection, tighten the
connection.
• Care must be taken for connecting the terminals in correct polarity. The
reverse connection may cause severe damage in regulator.
• Do not disconnect the connectors from UVC and terminals. If any
disconnection is found, connect the connectors in original position.
• Do not connect any wrong side and wrong connection will cause damage in
regulator.
• Do not keep open the UVC door as well as regulator box and terminal covers.
Open door may give chance to enter the dust metallic things inside and this
may cause any short circuit in the regulator.
PERIODICAL MAINTENANCE INSTRUCTION FOR ERRU
• In case of fuse blown, is suggested to use proper HRC fuse. Do not tie with
wire and this wire-fuse will cause any damage in the regulator.
• Protections are safety for our systems; so do not bypass the protecting
systems lie, OVP and fuse.
• Store the downloading unit in safe place and do not keep in very high
temperature.
• Do not press the LCD display screen and pressing will cause the damage to the
LCD.
• Use proper tools for opening and removing the units from the regulator.
LIST OF FAULTS AND THEIR SOLUTIONS
LIST OF FAULTS AND THEIR SOLUTIONS
LIST OF FAULTS AND THEIR SOLUTIONS