Static Kramer System
Static Kramer System
Static Kramer System
Instead of wasting the slip power in the rotor circuit resistance, a better
approach is to convert it to ac line power and return it back to the line. Two
types of converter provide this approach:
At synchronous speed (s=0) the power factor is the lowest and increases
as slip increases. The PF can be improved close to synchronous speed
by using a step-down transformer. The inverter line current is reduced
by the transformer turns ratio -> reduced PF.
SPEED CONTROL
The average o/p voltage of the diode bridge connected to the slip rings is
given by
3 2𝐸2 𝑠
𝑉𝐶 =
𝜋
𝑉𝐶 =1.35 𝐸2 s
𝐸2 = RMS line voltage on the rotor side
S=slip
Inverter mode:
3 2𝐸𝑙 𝑠
𝑉𝑖𝑛 = cos 𝛼 𝐸2 = RMS line voltage of ac supply
𝜋
𝑉𝐶 𝐼𝐶
𝑇=
𝑠𝜔𝑠
𝑁1
𝑉𝐶 = 𝑉𝑖𝑛 = 1.35 𝐸𝑙 cos 𝛼 & 𝑠= − cos 𝛼
𝑁2
1.35𝐸𝑙 𝐼𝐶
𝑇=
𝑁1
𝜔
𝑁2 𝑠
Torque speed characteristics of static
Kramer system