Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 7

COMPUTER AIDED ANALYSIS AND DESIGN

OF STRUCTURES

Design of 50,000 Gallon


(Elevated Water Tank)
(varying condition)

Presented By :
Abdullah Ejaz (MCE171004)
Varying Condition

Hydraulic Head is increased by 3 feet


(60feet to 63 feet) after construction of
Foundation.
Architectural
Drawing
Changes in Result

• Seismic weight is increased from 1502 K to 1552 K.


• Time period is increased from 1.13 to 1.29 sec.
• Base shear is decreased from 534 K to 470 K.
• Ft is increased from 34 to 37 K.
External Stability Checks
FACTOR OF SAFETY

• OVER TURNING
OLD = 2.25
NEW = 2.71
• SLIDING
OLD = 2.35
NEW = 2.71
Changes in Drawings

•Shaft top radial reinforcement


spacing is decreased from #6-10"c/c
to #6-9"c/c.
•Shaft bottom radial reinforcement
spacing is decreased from #6-10"c/c
to #6-9"c/c.
Thank You