Electro - Proportional Valves
Electro - Proportional Valves
PROPORTIONAL
VALVES
1
HYDRAULIC CONTROL TECHNOLOGY
Closed Loop
Performance
Open Loop
Proportional Valves Proportional
Conventional
Valves
2
COMPARISON BETWEEN
CONVENTIONAL AND PROPORTIONAL VALVES
SL.
No. Description Conventional Proportional
1 Setting Mechanical Electrical
2 Stage Control Single Multiple
3 Slope Control In Steps Smooth Slope
4 Circuit Complex Simple
5 Size of Blocks, Pipes Large Small
6 Power Saving Circuit Complicated Simple
7 Feedback Not Available Available
3
DEVELOPMENT OF
ELECTRO - PROPORTIONAL VALVES
4
SALIENT FEATURES OF
ELECTRO PROPORTIONAL VALVES
Basic Just Like
Conventional Simple High
Structure
Valve Reliability
Directly High
Operated Powerful Resistance
Type Driving Against
Contamination
With Current
Amplifier Feedback Function, Stable Control
Dither
DEVICES FOR THE PROPORTIONAL CONTROL
Indication
Feedback signal in
Power Closed Loop Circuit
Setting Device Amplifier Prop. Valve Sensor
6
SIGNAL SEQUENCE
Control Panel
0~10V
Command Amplifier Prop.
Actuator
Signal Valve
Sensor
7
PRINCIPLE OF OPERATION
Plunger Coil
Spring Force
Magnetic Force
D C Current
ELECTRO MAGNET
PERMANENT MAGNET
9
PRINCIPLE OF BASIC SOLENOID OPERATION
NO ELECTRIC
CURRENT
PLUNGER
COIL
Force
Stroke Stroke
100 % 100 %
70 % 70 %
Force
30 % 50 %
Force
30 %
Stroke Stroke
11
COMPARISON : FORCE V/S STROKE
Conventional Proportional
Spring Curve
Spring Curve
100 %
70 %
100 % 50 %
Force
Force
70 %
30 %
30 %
Stroke Stroke
12
COMPARISON OF SOLENOID CONSTRUCTION
Air Gap COIL
CONVENTIONAL
SOLENOID
ARMATURE
ARMATURE
1
3
CONSTRUCTION DETAILS OF PROP. SOLENOID
Spring
Air Gap
Plunger
14
PROPORTIONAL HYDRAULIC CONTROL - RANGE
Maximum Flow
Maximum
Operating
Valve Type Pressure
Kgf/Cm2 1 2 3 5 10 20 30 50 100 200 300 500
L /min
1000
206 W 02 03 06 10
E Series
03 06
16
STEP RESPONSE
STEP SIGNAL 0 ~ 100 %
Fig. Shows the Valve requires
100
80 ms to go from 0 to 100% Stroke and
70 ms to fully close.
STROKE %
50
i.e., 150 ms is required to complete one cycle.
150 ms - 1 Cycle
1000ms ( 1 Sec ) - ? Cycles
0 1000 X 1 = 6.6 Cycles / Sec ( Or 6.6 Hz )
80 0 70
TIME ( ms ) 150
STEP SIGNAL 25 ~ 100 % STEP SIGNAL 10 ~ 90 %
100
90
75
STROKE %
STROKE % 50
25
0
0 50 0 40 70 0 60
TIME ( ms ) TIME ( ms )
STEP RESPONSE : A RESPONSE MADE WHEN THE INPUT SIGNAL
SUDDENLY CHANGES FROM A GIVEN VALUE TO ANOTHER GIVEN VALUE
17
FREQUENCY RESPONSE
– Frequency
•Is the number of times any
action occurs in a given
measure of time.
Unit is Hz (Cycles per Second)
18
PHASE LAG
– The time required for the output to recreate
the input command. Measured in Degrees.
Cyclic Input
Cyclic Out put
- 60 -30
- 80
Gain ( dB)
-100
-120
Phase
-140
-160
-180
20
HYSTERESIS
Hysterisis Hysteresis
without Dither with Dither
200 200
180 180
160 160
Pressure Kgf / Cm2
Current ( mA ) Current ( mA )
Dead Band Dead Band
21
PROPORTIONAL ELECTRO – HYDRAULIC
PILOT RELIEF VALVE
PLUNGER With
COIL Safety Valve
SPRING
PLUNGER POPPET
SEAT SPRING
AIR VENT
Pr. Adj.
MANUAL PR.
Screw for
ADJ. SCREW IRON CORE Safety valve
TANK PRESSURE
PORT PORT
Without
Safety Valve
22
PROPORTIONAL ELECTRO – HYDRAULIC
PILOT RELIEF VALVE
STEP RESPONSE
Flow Rate : 2 L / min
Kgf / Cm2 Trapped Oil : 40 cm3
90 Volume
Viscocity : 30 cSt
70
Pressure
50
0.2 Sec
30
Step Signal
10
Time
23
PROPORTIONAL ELECTRO – HYDRAULIC
PILOT RELIEF VALVE
FLOW RATE VS PRESSURE
Viscosity : 30 cSt
A
250
235
220
B
Pressure Kgf / Cm2
160
145
130
C
70
55
40
0 1 2 L / min
Flow Rate
24
PROPORTIONAL ELECTRO – HYDRAULIC
PILOT RELIEF VALVE
FREQUENCY RESPONSE
Frequency ( Hz)
0.1 0.2 0.4 0.7 1 2 4 7 10 20 40 70
0
- 20 -10
- 40 -20
Gain
Phase ( deg.)
- 60 -30
- 80
Gain ( dB)
-100
-120
Phase
-140
-160
-180
25
PROPORTIONAL ELECTRO – HYDRAULIC
PILOT RELIEF VALVE
CONTROL PRESSURE VS INPUT CURRENT
250
A
200
Pressure Kgf / Cm2
150
100 B
50
C
0
0 200 400 600 800 1000
Input Current mA
26
PROPORTIONAL ELECTRO – HYDRAULIC
RELIEF VALVE
PROPORTIONAL
PILOT RELIEF
AIR VENT VALVE WITH
SAFETY VALVE
200
Pressure 160
120 0.2s
80 Step Signal
40
Time
Flow Rate : 200 L / min )
Loading : 1 ltr.
Volume
Viscocity : 30 cSt
28
COMPARISON OF CONVENTIONAL &
PROPORTIONAL PRESSURE CIRCUIT
Conventional Circuit Proportional Circuit
Switch ON Sol. a – d to get Only One Valve is required
4 different pressures ., By changing the Input
Current, the Pressure can
be changed.
29
PROPORTIONAL ELECTRO – HYDRAULIC
FLOW CONTROL VALVE
40W Series PR. COMPENSATOR PISTON
( Direct Type )
INLET PORT
DRAIN PORT
Graphic
Symbol
OUTLET PORT
O
M SPOOL ORIFICE SLEEVE
31
STEP RESPONSE
40 Ohm 10 Ohm
L / min L / min
140 125 L / min 150 125 L / min
120 125
100 100
Flow Rate
60 L / min
Flow Rate
80 60 L / min
75
60
50 0.2s
40 0.2s
25
20 Step Signal
Step Signal
0 0
Time Time
34
FREQUENCY RESPONSE
40 Ohm
Frequency ( Hz )
0.1 0.2 0.7 1 2 4 7 10 30
0 0
- 20 - 10
- 40 - 20
- 60 Gain
Phase (deg. )
Gain ( dB )
- 80
- 100 Phase
- 120
- 140
- 160
- 180
Input Current : 460 ± 70 mA
35
COMPARISON OF CONVENTIONAL &
PROPORTIONAL FLOW CIRCUITS
Forward Backward Forward Backward
Low High
Speed Speed
Conventional Proportional
37
LOAD SENSING -
COMPARISON OF HEAT GENERATION
HEAT GENERATED
= P x Q x 860 Kcal / Hr
612
= 40 x 40 x 860
612
= 2248 Kcal / Hr
38
LOAD SENSING -
COMPARISON OF HEAT GENERATION
VENT
LINE
Set
Increase pressure At
100
P Bar
REMOTE CONTROL
RELIEF VALVE
39
LOAD SENSING -
COMPARISON OF HEAT GENERATION
Flow Control
Valve Set
At
P 100
Bar
40
LOAD SENSING -
COMPARISON OF HEAT GENERATION
HEAT GENERATED
= P x Q x 860 Kcal / Hr
612
= 40 x 15 x 860
612
= 843 Kcal / Hr
41
CONVENTIONAL POWER SAVING VALVE
FLOW CONTROL
VALVE
RELIEF VALVE
TANK DRAIN
INLET PORT OUTLET PORT
PORT PORT
42
PROPORTIONAL ELECTRO – HYDRAULIC
RELIEF & FLOW CONTROL VALVE
40W - 10W Series FLOW CONTROL
SOLENOID
PROPORTIONAL
PILOT RELIEF
VALVE WITH
SAFETY VALVE
TANK DRAIN
INLET PORT OUTLET PORT
PORT PORT
43
POWER SAVING CIRCUIT
Conventional Proportional Circuit
Circuit Energy Saving
Energy Saving Energy Saving
Q Q Q Q
Power
loss Power Power Power
loss loss loss
P P P P
46
PROPORTIONAL ELECTRO – HYDRAULIC
DIRECTIONAL AND FLOW CONTROL VALVE
INPUT CURRENT V/S FLOW
L/ min
120
100 AB A B
80 P T P T
Flow Rate
60
40
20
0
1000 800 600 400 200 0 200 400 600 800 1000
Input Current mA
48
PROPORTIONAL ELECTRO – HYDRAULIC
DIRECTIONAL AND FLOW CONTROL VALVE
PRESSURE DIFFERENCE V/S FLOW
L /min
140 A B
120 750 mA
P T
700 mA
Flow Rate
80
80
A B
700 mA
120
P T 750 mA L / min
140
49
LINEAR VARIABLE DIFFERENTIAL TRANSFORMER
INPUT ( LVDT )
IRON CORE
OUTPUT
51
HYBRID SERIES PROPORTIONAL VALVES
24 V DC Power
Supply Pressure display panel (option)
Power Amplifier
Command
Signal
Voltage Pressure Sensor
Input Incorporated
Voltage
Output for
Pr. monitor
Alarm Signal
Output
Proportional Electro Hydraulic Relief Valve
52
INSTALLATION REQUIREMENT
Air Vent
Air Vent
GOOD EXAMPLE
SOL
Air Vent
SOL
SOL
Air Vent
SOL
BAD EXAMPLE
SOL
SOL
ELEVATORS
ROLLING MILLS
PLANERS
INJECTION MOULDING MACHINES
PRESSES
SURFACE GRINDING MACHINES
55
Proportional Direction and Flow Control Valve
with LVDT