Professional Documents
Culture Documents
Responsi Unit Pelayanan
Responsi Unit Pelayanan
Responsi Unit Pelayanan
L = 300 m L = 200 m
D = 400 mm D = 400 mm
D = 400 mm
D = 400 mm
D = 300 mm
L = 500 m
L = 500 m
L = 500 m
5 L = 300 m 4 L = 200 m 3
D = 200 mm D = 300 mm
D = 400 mm
L = 600 m
L = 600 m
Q = 100 L/detik 8 L = 300 m 7 Q = 100 L/detik
D = 200 mm
Jawaban
Q = 400 L/detik
L = 300 m L = 200 m
D = 400 mm D = 400 mm
D = 400 mm
D = 400 mm
D = 300 mm
L = 500 m
L = 500 m
L = 500 m
L = 300 m L = 200 m
D = 200 mm D = 300 mm
Q = 100 L/detik Q = 100 L/detik
D = 300 mm
D = 400 mm
L = 600 m
L = 600 m
Q = 100 L/detik L = 300 m Q = 100 L/detik
D = 200 mm
Jawaban
6 1 Q = 400 L/detik 2
L = 300 m L = 200 m
D = 400 mm D = 400 mm
D = 400 mm
D = 400 mm
D = 300 mm
L = 500 m
L = 500 m
L = 500 m
I II
5 L = 300 m 4 L = 200 m 3
D = 200 mm D = 300 mm
Q = 100 L/detik Q = 100 L/detik
D = 300 mm
D = 400 mm
L = 600 m
L = 600 m
III
L = 300 m L = 200 m
D = 400 mm D = 400 mm
D = 400 mm
D = 400 mm
D = 300 mm
L = 500 m
L = 500 m
L = 500 m
I II
5 4 3
L = 300 m L = 200 m
D = 200 mm D = 300 mm
Q = 100 L/detik Q = 100 L/detik
D = 300 mm
D = 400 mm
L = 600 m
L = 600 m
III
12 R
11 Q = 7,2867 4
Q = 21,03 19
Q = 4,2223 20
5
Q = 7,1855
18 6
10 9
Q = 41,86 Q = 4,0307
Q = 5,9542 R 8 10 7
Q = 6,1024
Q = 5,9542
Data Lain
Jalur L (m) D (mm)
Jalur L (m) D (mm)
1–2 150 103,2
16 – 8 210 295,6
2 – 17 300 187,2
8–9 270 295,6
17 – 3 240 103,2
9 – 14 360 103,2
3–4 350 103,2
14 – 15 130 150,2
4 – 19 270 103,2
15 – 1 130 150,2
19 – 21 30 103,2
14 – 13 50 103,2
21 - 5 180 103,2
13 – 12 100 84,4
5–6 280 103,2
12 - 11 210 150,2
6 – 20 180 103,2
11 – 10 240 187,6
20 – 2 200 103,2
10 – 18 180 234,6
5–7 400 187,6
18 – 9 90 150,2
7 - 16 280 234,6
Jawaban
Q = 6,2653 Q = 3,4504 Q = 4,9192
14 1
13
Q = 2,8149 15 2 17 3
12 R III
11 Q = 7,2867 4
Q = 21,03 19
Q = 4,2223 20
I II 5
Q = 7,1855
18 6
10 9
Q = 41,86 Q = 4,0307
Q = 5,9542 R 8 10 7
Q = 6,1024
Q = 5,9542
Jawaban
Q = 6,2653 Q = 3,4504 Q = 4,9192
14 1
13
Q = 2,8149 15 2 17 3
12 R III
11 Q = 7,2867 4
Q = 21,03 19
Q = 4,2223 20
I II 5
Q = 7,1855
18 6 21
10 9
Q = 41,86 Q = 4,0307
Q = 5,9542 R 8 16 7
Q = 6,1024
Q = 5,9542
Jawaban
Trial I
No. Node Kontrol
Diam. Qasumsi Qmutlak
Loop No. Pipa C L (m) V Hf (m) K = Hf/Q dQ Qkoreksi
dari ke (m) (m3/detik) (m3/detik) A (m2)
(m/detik)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
I 18 10 130 180 0,2346 0,013 0,013 0,043 0,3 0,088 6,78 -0,00129 0,012
10 11 130 240 0,1876 0,008 0,008 0,028 0,3 0,152 18,33 -0,00129 0,007
11 12 130 210 0,1502 0,005 0,005 0,018 0,3 0,172 32,43 -0,00129 0,004
12 13 130 100 0,0844 0,002 0,002 0,006 0,3 0,161 95,75 -0,00129 0,000
18 9 130 90 0,1502 -0,005 0,005 0,018 0,3 -0,074 13,90 -0,00129 -0,007
14 9 130 360 0,1032 0,003 0,003 0,008 0,3 0,457 182,38 -0,00129 0,001
14 13 130 50 0,1032 -0,003 0,003 0,008 0,3 -0,064 25,33 -0,00129 -0,004
Jumlah 0,893 374,89
II 1 2 130 150 0,1032 0,003
2 20 130 200 0,1032 0,003
6 20 130 180 0,1032 -0,003
5 6 130 280 0,1032 -0,003
7 5 130 400 0,1876 -0,008
16 7 130 280 0,2346 -0,013
8 16 130 210 0,2956 -0,021
9 8 130 270 0,2956 -0,021
14 9 130 360 0,1032 -0,003
15 14 130 130 0,1502 -0,005
1 15 130 130 0,1502 -0,005
Jumlah
III 2 17 130 300 0,1876
17 3 130 240 0,1032
3 4 130 350 0,1032
19 4 130 270 0,1032
21 19 130 30 0,1032
5 21 130 180 0,1032
5 6 130 280 0,1032
6 20 130 180 0,1032
2 20 130 200 0,1032
Jumlah
Kunci
1. Lihat soal!
2. Pastikan diketahui:
• Q input dan output
• Panjang pipa
• Diameter pipa
3. Buat blok loop
4. Buat rencana alur pipa dan sistem loop-nya
5. Kalkulasi sesuai jawaban diatas!
Kunci
• L, dalam satuan meter
• D, dalam satuan meter
• K = L x [(10,67)/(C1,85) x (D4,87)]
• Qasumsi = V.A
• hf = (Q/(0,2785 x C x D2,63))1,85 x L
• hf/Qasumsi
• dQ = -(Ʃhf)/[1,85 x (Ʃhf/Q)]
• Qkoreksi = Qasumsi – dQ
• dQ/Qkoreksi ≈ 0
• Lihat dQ mendekati 0, ok!!! atau dQ/Qkoreksi ≈ 0
Soal 1