Professional Documents
Culture Documents
Lara Čižmek, Šebojka Komorsky-Lovrić, Ivana Novak Jovanović
Lara Čižmek, Šebojka Komorsky-Lovrić, Ivana Novak Jovanović
Chillies are used as pungent flavor in food, natural plant colour, pharmaceutical ingredients and as sprays for riot
control and self-defense
Capsaicin
trans-8-methyl-N-vanillyl-6-nonenamide
pharmaceutical properties (topical analgesic
against arthritis pain and inflammation,
antimutagenecity effects and a high antioxidant
© 2011 American Association for Cancer Research
activity) Figure 1. Chemical structure of capsaicin.
Introduction Methods Results Conclusion
Bhut Jolokia 880 000 – 1 041 427 Chilli pungency is measured in Scoville Heat Units (SHU)
Scoville organoleptic test (Scoville, 1912)
Red Savina 350000 – 577000
- organoleptic method (subjective)
Fatalli 125000–400000
Spectrophotometry
Habanero Orange 150000 – 325000 (Perucka and Oleszek, 2000; Davis et al., 2007)
Determination of the mass fraction of a depositable metals in materials (A. Doménech-Carbó et al., 2004)
Recently, the method was used for determinantion of antidepressants drugs (A. Doménech-Carbó et al., 2013)
Introduction Methods Results Conclusion
Square-Wave Voltammetry
Experimental conditions: frequency 150 Hz and pH 11
Electrolyte: 0.1 M KNO3 buffered to the specific pH
Working electrode: paraffin-impregnated graphite rod (diameter 5 mm, length 50 mm)
Introduction Methods Results Conclusion
Now, each specimen will contain a mass m of pristine sample (containing an unknown mass fraction f of X), a mass mR of
reference compound with known mass fraction fR of R, and a mass mXadd of added standard with known mass fraction fX of X.
Then, the ip(X)/ip(R) ratio should satisfy the relationship:
GX – electrochemical coefficient of response for X
Accordingly, plots of iX/iR vs. mX/mR should give a straight Table 1. Example of the prepared samples for measurement.
line of slope (GX/GR)(MR/MX)(fX/fR) and ordinate at the
Sample m / mg mR / mg mXadd / mg m/mR mXadd/mR
origin (GX/GR)(MR/MX)(m/mR)(f/fR).
1 15 30 0 2 0
Then, the absolute mass fraction of X in the sample can be 2 15 30 0.01 2 0.00033
6 15 30 0.5 2 0.0168
7 15 30 1 2 0.0330
DILLUTION FACTOR
Introduction Methods Results Conclusion
6e-4
Indigo Capsaicin Capsaicin
8e-4
1e-4
4e-4
Indigo
6e-4
2e-4
0
f 0 4e-4
f
/A
/A
/A
-1e-4 -2e-4 2e-4 f
b
b
-4e-4
0
-2e-4
-6e-4 b
-2e-4
-3e-4 -8e-4
-1.0 -0.5 0.0 -1.0 0.5 -0.5 1.0 0.0 0.5 -0.2 1.00.0 0.2 0.4 0.6 0.8 1.0
4e-4
8e-4
4e-4
8e-4
4e-4
add
add
add
without
m
m
m
add= standard
mxxxxadd
m add
xx =
0.01
10.5
===0.1
0.05
0.03 addition
mg/mg
mg/mg
mg/mg
mg/mg
mg/mg
mg/mg
4e-4
6e-4
6e-4 Table 2. Net peak currents and net peak
2e-4
2e-4
4e-4
2e-4
potentials of two electroactive compounds.
4e-4
2e-4 Standard
0
0 INDIGO CAPSAICIN
2e-4 addition
0 ff
A
///AA
f f
0 without standard E = -0.697 V E = 0.303 V
f f
addition i = 15.38 A i = 9.694 A
0
-2e-4 f
-2e-4
-2e-4
-2e-4 E = -0.685 V E = 0.295 V
0.01 mg/mg
3e-4 i = 18.83 A i = 15.19 A
-2e-4 bb
-4e-4 b b b
-4e-4 b E = -0.689 V E = 0.305 V
-4e-4
-4e-4 0.03 mg/mg
b i = 19.20 A i = 16.84 A
-4e-4
-6e-4
3e-4
E = -0.699 V E = 0.266 V
0.05 mg/mg
-6e-4
-8e-4
-6e-4 i = 38.60 A i = 53.39 A
Capsaicin -1.0
-1.0 -0.5
-0.5 0.0
0.0 0.5
0.5 1.0
1.0
2e-4 E = -0.695 V E = 0.258 V
0.1 mg/mg
E
E
E /// V
V vs.
V vs. Ag/AgCl
vs. Ag/AgCl
Ag/AgCl i = 50.40 A i = 65.53 A
Indigo
5e-5
-1.0 -0.5 0.0 0.5 1.0 Figure 7. Voltammograms for all the additions of capsaicin microparticles in
E / V vs. Ag/AgCl analysis of chilli pepper Bhut Jolokia.
Introduction Methods Results Conclusion
𝑓 = 0.0703976
Red Savina
Jalapeno (SHU
(SHU
2500
350000
– 5000)
– 577000) Habanero
Ancho Orange
(SHU 1000 (SHU 150000 – 325000)
– 2000)
Fatalli (SHU 125000 – 400000) Hungarian Wax Pepper (SHU Carolina Cayenne (SHU 100000 – 125000)
1000 – 8000)
Introduction Methods Results Conclusion
SHUliterature SHUexperimental
Quantification of capasaicinoids in chilli pepper samples used as food additives can be made using standard addition method using
the voltammetry of microparticles methodology.
The method is based on the record of the solid-state voltammetric signals for the electroactive analyte and an electroactive
reference compound assuming that such signals are independent and appearing at separated potentials.
The method is reproducible and applicable to samples with higher concentrations of capsaicinoids.
In samples with lower concentration of capsaicinoids, estimated pungency is not in agreement with provided literature data
probably due to the addition of relatively high concentration of standard capsaicin which then gives higher response then the ones
in sample.
Under optimized conditions, the method provides satisfactory results for the determination of capsaicinoids in real samples of
chilli peppers.
The use of a standard addition method based on SQWV measurements on sample plus reference-modified PIGEs provide a fast
and sensitive procedure for determining the mass fraction of capsaicinoids in solid samples of chilli peppers.
The financial support by the Croatian Foundation in the frame of the project number IP-11-2013-2072 is gratefully acknowledged.