SCOPE AND PURPOSE
Processing of Radiograph
After exposing the film, we process it in dark room.
Developer reduce the exposed AgBr into black metallic
silver. Developer time is 5 minutes at 68 C.
Fixer remove all unexposed AgBr and harden the
image. Fixer time is twice the clearing time.
Finally washing in running water to remove fixer
solution from film.
Drying of radiograph by placing film in a drying cabinet
with warm circulating air.
Manual Processing
INTERPRETATION
Finally interpretation, which is to judge a radiograph
for film quality and weld quality.
(Re-shoot due to Many Reasons and CRS).
Film Quality:
i) Film identification ii) Location Markers iii) IQI
sensitivity
iv) Film Density v) Film physical quality
Weld Quality:
To identify and differentiate various types of
discontinuities on radiograph.
It is important for interpreter to know weld joint
configuration, welding process and welding
position.
Interpretation
.
INPUT
-RT Request
-Shooting Status
-RT Reports
-RTFI Assessment
RT Request
Shooting Status
RT Report
.
RTFI Assessment
OUTPUT
REPORTS