Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 15

TABLE OF CONTENTS

 THEORETICAL WORK
1.GAS ANALYZER

1.DYNAMOMETER

 EXPERIMENTAL WORK

 PLAN/GANTT CHART
Theoretical Work
 GAS ANALYZER
 ORSAT GAS ANALYZER
CARBON MONOXIDE (CO)
CARBON DIOXIDE (CO2)
OXYGEN (O2)
 ABSORPTION REAGENTS
CUPROUS CHLORIDE SOLUTION (CuCl2)
 PYROGALLOL SOLUTION (C6H3(OH)3)
 POTASSIUM HYDROXIDE(KOH)
DYNAMOMETER
EDDY CURRENT DYNAMOMETER
 The EC absorbers provide a quick load change rate for
rapid load settling.
 Eddy current dynamometers require an electrically
conductive core, shaft, or disc moving across a
magnetic field to produce resistance to movement.
EXPERIMENTAL WORK
 DETERMINING THE CALORIFIC VALUE(40.2MJ/kg)
AND FLASH POINT(165 c) OF BIODIESEL

 BLENDS OF BIODIESEL

 MOUNTING OF ENGINE AND DYNAMOMETER

 COUPLING OF ENGINE AND DYNAMOMETER


THROUGH BELT AND PULLY
ENGINE SPECIFICATION
SINGLE CYLINDER,175 CC FOUR STROKE DIESEL
ENGINE

 RATED RPM 2600rpm

 Indicated power 4.41kw(approx. 6HP)


GANTT CHART
ABSORPTION REAGENTS
 CUPROUS CHLORIDE SOLUTION
Absorption of Carbon monoxide
3 g NH4Cl +27 g CuCl2+100 ml Distilled H2O
PYROGALLOL SOLUTION
Absorption of Oxygen
 6 g of pyragallod (C6H3(OH)3)+30 g of
KOH +30 ml Distilled H2O
POTASSIUM HYDROXIDE
 Absorption of carbon dioxide CO2
30 g of KOH +100ml Distilled H2O
Indicated power calculation
 Pi=p x A x L x N/(2x60)
 p=mean effective pressure=576kpa

 A=Piston area=4.41x10-3 m2

 L=Stroke length=80mm

 N=Rated revolution=2600rpm