Disain Jaringan Penukar Panas (Heat Exchanger Network Design)

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 47

Disain Jaringan Penukar Panas

(Heat Exchanger Network Design)


TK 4153 Perancangan Proses Teknik Kimia
Semester Ganjil 2018/2019
Teknik Kimia Universitas Riau
[Contains Material Developed by Dr. Daniel R. Lewin, Technion, Israel]
Onion Model for Process Design
Onion Model - Reactor
Onion Model - Separator
Onion Model – Heat Recovery
Onion Model - Utility
Hierarchy Process Design
Reactor Design

Separator Design

HEN Design

Utility Design
Process design is strongly coupled with Heat
Exchanger Networks
Topics
The “pinch”
The design of HEN to meet Maximum
Energy Recovery (MER) targets
The use of the Problem Table to
systematically compute MER targets
Objective
Given data on hot and cold streams,
student should be able to:
Compute the pinch temperatures
Compute MER targets
Design a simple HEN to meet the MER
targets
Investasi versus Energi
Investasi vs Energi
Disain jaringan alat penukar panas berurusan
dengan persoalan berikut,
Disajikan persoalan:
• Aliran panas NH dgn Laju alir Kapasitas
panasnya akan didinginkan dari Suhu pasokan
THS menjadi Suhu capaian THT.
• Aliran dingin NC dgn Laju alir kapasitas
panasnya akan dipanaskan dari Suhu pasokan
TCS menjadi Suhu capaian TCT.
Investasi vs Energi
Tugas Disain:
Jaringan penukar panas optimum, hubungan
antara aliran panas dengan aliran dingin dan
antara aliran dengan sistem utilitas (furnace,
hot-oil, cooling water, refrigerant).

Kondisi Optimum?
Tawar menawar antara Biaya INVESTASI dan
Biaya ENERGI.
Contoh STEAM
PENDINGIN
T out T out T out

H H H
T in C T out

T in C T out

T in C T out

T in T in T in
Apakah jaringan meminimalkan biaya peralatan?
Contoh STEAM
PENDINGIN
T out T out T out

T in HE HE HE T out

T in HE HE HE T out

T in HE HE HE T out

T in T in T in
Apakah jaringan meminimalkan biaya energi?
Contoh STEAM
150o 150o 150o
PENDINGIN
100 100 100
CP = 1 300o 100 200o

CP = 1 300o 100 200o

CP = 1 300o 100 200o

50o 50o 50o


CP = 1 CP = 1 CP = 1

Disain A: ∑ (AREA) = 20,4 A = Q/U.∆Tlm


Contoh
150o 150o 150o

CP = 1 300o 100 200o

CP = 1 300o 100 200o

CP = 1 300o 100 200o

50o 50o 50o


CP = 1 CP = 1 CP = 1

Disain B: ∑ (AREA) = 13,3


Konsep Dasar
Laju alir kapasitas panas
T TS = Suhu pasokan

TT TT = Suhu target

H = m x Cp x T
T
CP

CP = m x Cp = H/T (MW/oC)

TS = Laju Alir Kapasitas Panas


= Laju Alir x Kapasitas Panas Spesifik

H
H
∆T minimum
∆Tmin = beda suhu terkecil yang diizinkan
80o 70o

100o 60o 100o 60o


HE HE

50o 40o
A B
Sistem manakah yang memiliki beda suhu
kecil dari 20o ? (jika ∆Tmin = 20o)
∆T minimum

20o 30o
80o 70o

100o 60o 100o 60o


HE HE

50o 40o
10o 20o

A B
Tidak memenuhi aturan ∆Tmin = 20o
Beban Penukar Panas
30o T1 = 70o

Data: 100o 60o


• CP aliran panas = 0,3 MW/oC HE
• CP aliran dingin = 0,4 MW/oC
40o
20o
Periksa:
• T1 = 40 + (100 – 60) (0,3/0,4) = 70o (OK)

Beban penukar panas:


• Q = 0,4 (70 – 40) = 0,3 (100 – 60) = 12 MW
Luas permukaan perpindahan (A)
Formula:
A = Q/(U.∆Tlm)
Jika diketahui:
•Koefisien perpindahan panas overall, U = 1,7 kW/m2 oC
•∆Tlm = (30 – 20)/loge(30/20) = 24,66

Maka:
A = 12.000/(1,7 x 24,66) = 286,2 m2
Hmin = 10oC

Aliran Ts (oC) Ts (oC) H CP


(kW) (kW/oC)
P1 180 80 100 1,0
P2 130 40 180 2,0
D1 60 100 160 4,0
D2 30 120 162 1,8

Steam = 150oC, Air Pendingin = 25oC

Disain jaringan alat pemanas,


pendingin dan penukar panas
aliran-aliran sistem yang ada.
Ringkasan
Disain yang diajukan

Steam Air Jumlah


Alat
60 kW 16 kW 4

Apakah disain sudah


memenuhi ?
Diagram Entalpi-Suhu
T

T2

T1

H
∆H

Kasus 1 aliran panas


Diagram Entalpi-Suhu

T Kasus 2 aliran panas


T2

T1
H
∆H1 ∆H2
Diagram Entalpi-Suhu
C
T
∆Tmin = 20o
QHmin H

∆Tmin

H
QCmin
Diagram Entalpi-Suhu

Korelasi antara ∆Tmin, QCmin dan QHmin

Banyak masuk, Banyak keluar

QHmin + X → QCmin + X
Correlation between Tmin, QHmin and QCmin

More in, More out! QHmin + x  QCmin + x


Diagram Komposit

Aliran Ts (oC) Ts (oC) H CP


(kW) (kW/oC)
P1 180 80 100 1,0
P2 130 40 180 2,0
D1 60 100 160 4,0
D2 30 120 162 1,8
Diagram Komposit
Diagram Komposit
180oC

130oC

CP = 2+1=3

80 kW 150 kW 50 kW
Diagram Komposit
Diagram Komposit
HH,min = 54 kW

HCmin = 12 kW
HH,min = 54 kW

∆HCmin = 12 kW
Pinch Panas = 80oC

Pinch Dingin = 60oC


Diagram Komposit
Manipulasi kurva aliran panas dan dingin
sehingga memenuhi ∆Tmin
(Dilakukan dengan cara menggeser kurva ke
kiri ataupun ke kanan, sehingga jarak kedua
kurva terdekat tidak kurang dari harga ∆Tmin)

Hasil yang diperoleh:


QCmin dan QHmin pada ∆Tmin yang disyaratkan
Diagram Komposit

MER Target:
Pinch panas = 80oC
Pinch dingin = 60oC
QHmin = 54 kW
QCmin = 12 kW
Pinch Panas = 70oC

Pinch Dingin = 60oC

HCmin = 6 kW
Diagram Komposit

MER Target:
Pinch panas = 70oC
Pinch dingin = 60oC
QHmin = 48 kW
QCmin = 6 kW
Pinch
HH,min

“Pinch”

Tmin

HC,min
HH,min
Utilitas
Kurva Komposit Pemanas
Aliran Panas

“Pinch”

Tmin

Potensi Energi yang


bisa dipertukarkan

Utilitas Kurva Komposit


Pendingin Aliran Dingin

HC,min