Professional Documents
Culture Documents
Capacity Uprating of EPCL's VCM Production Plant Via Debottlenecking of Purification Trains
Capacity Uprating of EPCL's VCM Production Plant Via Debottlenecking of Purification Trains
Stream ID EDC
Flowrate 74492.5
(kg/hr)
Mass Fraction
EDC 0.979
TCE 906 PPB
HCl trace
VCM trace
EC trace
Water 0.021
Stream ID HB-
FEED
Flowrate 84046.5
(kg/hr)
Stream ID HEAVIES
Mass Fraction
Flowrate 9554
EDC 0.924
(kg/hr)
TCE 0.057
Mass Fraction
HCl trace
EDC 0.497
VCM trace
TCE 0.503
EC trace
HCl
Water 0.019
VCM
EC
Water trace
All Rights Reserved for UET KSK Campus and EPCL Only 2
Hi-Boil Column Rating Results
Data Available: Calculated:
Number of 30 Max. 2.56
Stages Flooding
Column 11 factor
Diameter (ft) Downcomer 1.2
Tray type Sieve Length (m)
Downcomer 0.159
Reboiler type Thermosiphon Velocity (m/s)
Height (ft) 60 Pressure Drop 27.4
(psig)
Tray Spacing 2
(ft)
All Rights Reserved for UET KSK Campus and EPCL Only 3
Vacuum Column Rating Results
Data Available: Calculated:
Number of 20 Max. 0.4
Stages Flooding
Column 5 factor
Diameter (ft) Downcomer 0.129
Tray type Sieve Length (m)
Downcomer 0.0237
Reboiler type Thermosiphon Velocity (m/s)
Height (ft) 48 Pressure Drop 1.82
(psig)
Tray Spacing 2.4
(ft)
All Rights Reserved for UET KSK Campus and EPCL Only 4