Air Test Rig Prm2

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 10

PERFORMANCE ANALYSIS OF

CENTRIFUGAL BLOWER
Submitted by
AKSHAY REDDY 4GL15ME002
SYED FAZLAIN 4GL15ME057
MANJUNATHA M 4GL14ME031
ARUNA S 4GL15ME005

Under the Guidance of


Dr. LAKSHMI DEVAMMA M M B.E, M.E, PhD, MISTE., MIE
Department of Mechanical Engineering
Government Engineering College
Kushalnagar- 571234
CENTRIFUGAL AIR BLOWER TEST RIG
Tabular column for Radial blade

Sl.no Speed Position of Venturimeter Suction head Pitot tube Time for 5
valve h1 h2 h1 h2 h1 h2 blinks
1 1769 Fully open 5 8 25 31 2 9 13.83
2 1773 Half open 5 4 25 33 3 7 14.04
3 1776 Quater open 3 2 22 33 5 7 16.61
4 2182 Fully open 9 7 34 45 3 13 8.67
5 2194 Half open 9 5 40 48 4 9 10.73
6 2200 Quater open 3 2 45 52 5 9 11.41
7 2852 Fully open 13 12 65 75 5 16 6.10
8 2866 Half open 8 14 67 75 4 12 6.73
9 2888 Quarter open 10 14 70 80 2 7 9.07
FORMULAE FOR CALCULATION:
for maximum speed
1) Input to Blower in kW: (IP)
Input to blower = n x 3600 = 5 x 3600 = 1.24 KW
t x Em 9.07 x 1600
2) Static Head developed due to air (Pitot tube):
Hsta = hsta x δw
1000 δa
Hsta = 10 x 1000
1000 x 1.193

= 8.38 m of air
Sl no Blower output Static head Volume flow rate Blower output Overall efficiency
in KW In m of air in m3/ hr In KW In %
1 0.813 5.03 0.257 0.201 24.73
2 0.801 6.70 0.214 0.223 27.84
3 0.667 9.22 0.159 0.228 33.67
4 1.29 9.22 0.285 0.410 31.78
5 1.04 6.70 0.267 0.279 26.82
6 0.986 10.06 0.226 0.354 35.90
7 1.87 8.38 0.357 0.466 24.91
8 1.45 7.45 0.335 0.389 26.82
9 1.24 8.38 0.349 0.456 36.77
Tabular column for Reverse blade
Sl.no Speed Position of Venturimeter Suction head Pitot tube Time for 5
valve h1 h2 h1 h2 h1 h2 blinks
1 1767 Fully open 3 4 13 20 2 6 12.98
2 1770 Half open 3 6 11 17 4 7 14.28
3 1772 Quater open 3 3 17 24 6 7 17.56
4 2194 Fully open 3 7 18 25 2 9 11.75
5 2198 Half open 2 6 22 30 2 7 12.78
6 2204 Quater open 5 5 27 36 3 7 12.61
7 2868 Fully open 6 10 35 45 3 11 7.38
8 2878 Half open 5 8 40 47 2 10 8.38
9 2896 Quarter open 2 5 45 52 4 6 10.23
Sl no Blower output Static head Volume flow rate Blower output Overall efficiency
in KW In m of air in m3/ hr In KW In %
1 0.886 5.86 0.189 0.173 20
2 0.788 5.029 0.214 0.618 21.32
3 0.640 5.86 0.202 0.814 28.75
4 0.957 5.86 0.225 0.206 21.52
5 0.880 6..70 0.202 0.211 24
6 0.892 7.45 0.225 0.264 29.6
7 1.52 8.38 0.285 0.372 24.47
8 1.34 5.86 0.257 0.270 20.14
9 1 7.54 0.214 0.251 25.1
Tabular column for Forward blade

Sl.no Speed Position of Venturimeter Suction head Pitot tube Time for 5
valve h1 h2 h1 h2 h1 h2 blinks
1 1758 Fully open 6 10 30 40 3 10 11.15
2 1760 Half open 4 7 35 41 2 7 12.74
3 1764 Quater open 2 4 32 37 5 7 15.10
4 2179 Fully open 10 14 55 61 2 13 7.98
5 2182 Half open 7 9 56 63 2 12 9.6
6 2189 Quater open 1 5 50 57 2 7 11.2
7 2801 Fully open 12 23 93 100 11 20 5.27
8 2822 Half open 10 16 94 100 6 14 6.08
9 2866 Quarter open 2 7 89 97 3 8 7.89