STRUCTURES-III

ANUSHA.J.GOPINATH
USN NO-1KF17AT001
TWO WAY SLAB
 Two way slabs are the slabs that are supported on
four sides.
 The loads will be carried in both the directions so ,
main reinforcement is provided in both direction for
two way slabs.
 The ratio of longer span to shorter span is less than
2.
Advantages:
 Simple framework.
 No beams-simplifying under floor services outside the
drops.
 Minimal structural depth.

Disadvantages:
 Drop panels may inerfere with larger mechanical
ducting.
 Vertical penetrations need to avoid area around
coloumns.
TYPES OF TWO WAY SLABS

TWO WAY EDGE


SUPPORTED SLABS

FLAT SLABS

TWO WAY COLUMN


SUPPORTED SLABS FLAT PLATES

WAFFLE SLABS
FLAT SLAB
 Flat slab are also known as beamless slab, is a type
of slab in which the flooring slab is directly
supported on columns without agency of beams.
 This is appropriate for heavier loads .
 Highly versatile elements used in construction
,providing minimum depth , fast construction and
allowing flexible column grids.
 They are provided in theatres ,factories, mills ,
shopping complex and other buildings.
Types of flat slabs
 Slabs without drops and column heads.
 Slabs with drops.
 Slabs with drops and column with column heads.
USE OF COMPONENTS OF FLAT SLAB
Uses of columns heads
 Increase shear strength of slab.
 Reduce the moment in slab by
reducing the clear or effective
span.

Uses of drop panels


 Increase shear strength of slab.
 Increase negative moment
capacity.
 Stiffen the slab and hence
reduce deflection.
PUNCHING SHEAR
 Always a critical consideration in flat slab design
around the columns.
 Shear reinforcement in the form of shear heads ,
studs or stirrup cages may be embedded in slab to
enhance shear capacity at edges of columns.
COLOUMN STRIP AND MIDDLE STRIP
 Column strip means a design strip having a width of
0.25L1 or 0.25L2 whichever is less.
 The remaining middle portion which is bound by
the column strips is called middle strip.
FRAMEWORK :
Thickness of flat slab
 Controlled by consideration of span to effective
depth ratios
 For slabs with drops the span to effective depth
ratios obtained in account of provisions shall be
multiplied by 0.9.
 For this purpose ,the longer span shall be considered
 The minimum thickness of flat slab is 125.
Direct design method
Conditions-
 there must be atleast 3 continuous spans in each
direction.
 Panels should be rectangular and ratio of longer span
to shorter span within a panel shouldn’t exceed 2.
 Design live load must not exceed three times the design
load.
 The successive span lengths in each direction must not
differ by more than one third of the longer span.
Design moment for a span

Mo=(WLn \ 8)

where Mo=sum of positive and negative


bending moment
W= total design load.
Ln=clear span