Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 37

OZONE

THERAPY
EXTRACORPOREAL BLOOD
OXYGENATION AND OZONATION
Dr Mohd Nasir Sulaiman
(EBOO)
B.Med.Sc.,MD (Ina)
EBOO

Main component used during this


process:
 Ozone Generator DrOzonAmin
 Oxygen Tank and Regulator
 Dialyzer
 Blood Flow
OZONE GENERATOR

• A generator that produces precise


medical ozone .

• The blood will not enter the


machine instead will pass through
the oxygen-ozone gas exchange
filter, then the treated blood
(Filtered and ozonized) is re-
infused to the patient
OZONE GENERATOR

The “Start Button” will need to be


depressed in order to begin the ozone
production.
OZONE GENERATOR
 The 10 stage dial is one of the
methods used to control and
adjust the ozone concentration
created by the ozone generator
(the other method is the
oxygen flow). See the section
“Adjusting the Ozone
Concentration” for more
information regarding the
operation of the 10 Stage Dial.
OZONE GENERATOR
THE OZONE OUTPUT “Chart”
The Ozone Generator is accompanied by an Ozone Output Chart. This is a
chart showing you the exact concentrations of ozone is capable of
producing, and the oxygen and ozone generator settings you will use to
obtain these ozone concentrations. Ozone generator is capable of producing
ozone at a wide range of concentration, from 1 ug/ml to 50 ug/ml.

O2 Flow Ozone Concentration Output Setting on Generator (ug/ml)

LPM Ml/min 1 2 3 4 5 6 7 8 9 10

0.12 120 7 14 19 22 27 32 38 42 48 50

0.5 500 3 4.5 6 7 8 10 12 16 18 20

1 1000 2 3.5 5 6.5 7.5 8.5 9.5 10.5 11 12


OZONE GENERATOR

The “Regulator” will need to double


check flow of oxygen.
OZONE GENERATOR

The “Timer/counter” will need to set.


OXYGEN TANK
Oxygen flow control by regulator
DIALYZER
The filter used during
treatment is called
Hollow Fiber.

It’s a semi-permeable
membrane used to filter large
particles while letting small
particles through

Dialyzer was tested with blood,


normal saline and ozone and did not
release the material.
DIALYZER Medical Ozone in

Ozone flow

blood out

blood in

blood flow
Waste out

The dialyzer is consisted of 2 compartments separated by a semi-permeable


membrane, one for blood flow and the other for ozone.

This is where the filtered blood will be mixed, and exposed to the ozone.
The Blood Flow Process

 There’s 2 types of blood flow where the


circulation is directly related to the vascular
access :
 Inner body (systemic circulation)
 Outer body (systemic extra corporeally)
The Blood Flow Process
 The items involved during this process:
 needle / branula(outlet),
 red blood line ,
 size 17 tube,
 pump,
 dialyzer,
 bypass chamber,
 blue blood line,
 Branula (inlet).
The Arterial and venous lines connected the
exchange gas capillary filter(dialyzer) with materials
resistant to corrosion by ozone
Blood Flow Process

A branula is
inserted to re-
infused the
filtered blood
back to the
patient.
EBOO PROCEDURE
 Two process will happen during this
treatment:

1. Blood will be filtered/cleanse.

2. Blood will be exposed to medical ozone.


EBOO PROCEDURE

Blood is
pumped out.
EBOO PROCEDURE

Pumped
40 ml/min

The Extracorporeal circulation is established by maintaining blood


flow 30-50 ml/min throughout peristaltic by Pump.
Blood still inside the tubing.
EBOO PROCEDURE

Clotting during eboo treatment


was prevented by dripping
hep-saline 20 drops/min
(500ml Nacl +7,500iu heparin)

Continuous just before the filter


Infusion set with
Hep-saline connect
to tubing size 17
EBOO PROCEDURE
• The Dialyzer functioned as for
hemodialysis, except that
instead of liquid, a mixture of
oxygen and ozone at different
concentrations circulated
around the capillaries

• Blood will flow towards the


dialyzer, filtered and exposed
to medical ozone.

If Bubble coming out from line out,


the bubble also can trap in the dialyzer
EBOO PROCEDURE
• In the blood circuit, the blood pump
maintained a constant flow of
40ml/13rpm.

• Medical ozone was produced by


DrOzonAmin apparatus which releases
a medical ozone about 2-6 ug/ml.

• The gas mixture flowed through the


capillaries of the filter and the blood
inside.

If Bubble coming out from line out,


the bubble also can trap in the dialyzer
EBOO PROCEDURE

Then the blood will go


to the bypass
chambers before
flowing back to the
tube to be re-infused.

Although gas microemboli are not performed, for extreme safety,


the line returning the blood to the patient is intercalated with one
air trap and a blood filter (bypass chambers).
EBOO PROCEDURE

A branula is
inserted to re-
infused the
filtered blood
back to the
patient.
Extracorporeal Blood Oxygenation & Ozonation or
EBOO Procedure

A One hour process.


Painless
Patients are able to:
*hold a conversation
*sleep
*watch television

Only a total of 2,400 ml from the 6,000 ml blood in our body


was filtered and ozonised during this procedure
During EBOO
Blood out. Blood being re-infused back
During EBOO
The difference
between the
blood pumping
in and the
filtered blood
coming out.
During EBOO

Plaque Plaque
DURING EBOO Plaque
AFTER EBOO

Clotted plaques being filtered


DURING END EBOO Plaque
END EBOO
Big Particle Trap
AFTER EBOO Small Particle
WHY IT WORKS
Filters toxins out of the blood
Filters fats out of the blood
Increases oxygen to the blood
Increases blood flow
Removes extra fluid from the blood and body
Formation of new blood vessels
Enhances immune function
Improves the quality of BLOOD
xx

xx xx

xx

xx

xx
xx

xx xx

Thank You
Kelantan, Malaysia Selangor, Malaysia

Surabaya, Indonesia Jambi, Indonesia Bangkok, Thailand

Vientiane, Laos Phnom Penh, Cambodia Manila, Philiphine

You might also like