BS 241 BR 80_04

Commissioning
FDMA System
GSM 900 / 1800

890 MHz 915 MHz 935 MHz 960 MHz GSM900


1710 MHz 1785 MHz 1805 MHz 1880 MHz GSM1800
UPLINK (UL) DOWNLINK (DL)

Transmit band Transmit band


of the Mobile Station of the Base Station

25 MHz 25 MHz
75 MHz 75 MHz

Guard band

C C
C C C 124 C C C 124'
1 2 3 374 1' 2' 3' 374'

200 kHz
C - Radio Frequency Channel (RFC)

Page 2 © Siemens, 2005


FDMA / TDMA System
Timeslot

1TS = 577 s
TDMA
1 TDMA frame =
8 TS = 4.615 ms frame

1
0
7
6
5
4
3 time
2
1
0

200 kHz frequency


Page 3 © Siemens, 2005
Base + Service Rack

BS-241 II Base Rack BS 241-II Service Rack

Page 4 © Siemens, 2005


Visual Check

Base Rack Service Rack


Visual Check

Extension Rack

Power à -48 V (-15% to 20%) Power Power -> 220 V (176 to 239 V)

using COSA
COBA / COSA DIP Switch COSA

ACT DIP Switch ACT DIP Switch ACT DIP Switch

TRX Conf.
Semirigid Wiring Semirigid Wiring

CAN BUS CAN BUS CAN BUS

TRX Conf.

DCBCTRL
Selic Cable Selic Cable voltage test
battery capacity
slot ID
PCM Link Cable BPORT Setting battery manufacture

finish

Page 5 © Siemens, 2005


Visual Check
COBA and COSA Jumper Setting

External Clock Synchronization

Page 6 © Siemens, 2005


Visual Check
ACT DIP Switch Setting

Rack Type Rack No Switch 1 Switch 2 Switch 3 Switch 4

1 2 3 4
Base Rack 0 off off off on
Extension Rack 1 on off off on

ON
Extension Rack 2 off on off on
Service Rack 3 on on off on
Service Rack 4 off off on on
Service Rack 5 on off on on ACT factory setting
Service Rack 6 off on on on
Service Rack 7 on on on on

Page 7 © Siemens, 2005


Visual Check
ACTM wiring

Not Used
ENVA No Name
9 PLN Off
10 Door
11 Fire
12 Shelter in Service
13 Major Rectifier
14 Temp. for Rack (Low)
15 Temp. for Rack (High)
16 Room Temperature
17 Outdoor Unit AC
18 AVR Automatic Bypass
19 ATS Fail
20 Arrester Fail
21 Genset Run
22 Low Volt Battery
23 PLN On
24 Battery Fuse Trip
25 Rectifier Module Fail
26 Spare
ENVA:9 ENVA:10 ENVA:11 ENVA:12 ENVA:13 ENVA:14 ENVA:15 ENVA:16 ENVA:17 ENVA:18 27 Spare

Page 8 © Siemens, 2005


Visual Check
Semirigid Wiring

Page 9 © Siemens, 2005


Visual Check
CAN - BUS

CAN OUT - 48
CAN OUT CAN IN CAN OUT CAN IN
Serial IF
CAN TEST LPA CAN TEST LPA CAN TEST LPA

Service 2/2 Service 2/1 Service 1 Base Extension 1 Extension 2

Page 10 © Siemens, 2005


Visual Check
Celic Cable
Ext. 1 CU 4 ... 7 CU 4 ... 7 CU 4 ... 7

Ext. 1 CU 0 ... 3 CU 0 ... 3 CU 0 ... 3

Ext. 2 CU 4 ... 7

Ext. 2 CU 0 ... 3

Base Rack Extension Rack 1 Extension Rack 2

SELIC Cable for BS240

Ext. 1 CU 8 ..11 CU 8 ..11

Ext. 1 CU 4 ... 7 CU 4 ... 7

Ext. 1 CU 0 ... 3 CU 0 ... 3

Base Rack Extension Rack

SELIC Cable for BS240XL

Page 11 © Siemens, 2005


Visual Check
DCBCTRL

_ +
Voltage test

Oerlikon :
Bit 0 -> on

ON
Battery Batt Bit 1 Bit 1 -> not used
Manufacture type Bit 0

Sonnenschein :
Bit 0 -> off
Bit 1 -> not used
ON

640 Ah
Batt. 0 320 Ah
capacity 160 Ah
80 Ah
Batt. 1 40 Ah
20 Ah
capacity
10 Ah
5 Ah

ACDCP 0 :
Bit 0 -> on
ON

Slot Bit 1 Bit 1 -> off


Slot ID ID Bit 0

ACDCP 1 :
Bit 0 -> off
Bit 1 -> on

Page 12 © Siemens, 2005


Visual Check
DCBCTRL

DCBCTRL Module in BS 241

Page 13 © Siemens, 2005


Visual Check
PCM Link

KRONE LSA DDF


12
10
11
9
1 2 3 4
8
6
7
5
GND

GND

GND

GND

4
A B A B A B A B 2
3
1
TX RX TX RX
5 6 7 8 9 10 11 12
GND

GND

GND

GND

A B A B A B A B
TX RX TX RX

Page 14 © Siemens, 2005


Visual Check
Top View

Base Rack BS240 (Top View)


Base Rack BS240 (Top View)

Service Rack BS240 (Top View)

Extension Rack BS240 (Top View)

Page 15 © Siemens, 2005


Commissioning Flow

TEI = ?
Timeslot = ? Base Rack Service Rack
SALUNAME = ?
BTSM = ? Set Rack -> 0 Create Rack à 3
no
Create ACDCP

data complete ?? Create ACT Create ACT

Create Battery
yes

Start Commissioning Create COSA

Create BPORT

Create LAPDLE
Turn on BTS
Check phase Set BTSM
phase 2

Set BTSEP
phase 1
Format BTSE Flash Create FANP Create FANP

Create CU login (phase 3)


Download SW
Create DULNA UnlockRequest BTSM
Activate SW Remote to BSC
Create DUVSWR
login (phase 2) channel
Create ENVABTSE
unlock TRX
CONNBSC BTSM BTS

Page 16 © Siemens, 2005


Configuration
PCMB, BTSM and Mapping Timeslot in Abis Interface

Page 17 © Siemens, 2005


Configuration
Link Connection
PCM 1 PCM 1
PCM 2 PCM 2
PCM 3 PCM 3
PCM 4 PCM 4
BPORT
0 1 2 3
Node QTLP
BTS A

BSC
Link Configuration :
BTS A and BTS C -> Star
PCM 1
PCM 2
PCM 3
PCM 4

BTS B -> multidrop from BTS A

PCM 1
PCM 2
PCM 3
PCM 4
BPORT BPORT
0 1 2 3 0 1 2 3

BTS B BTS C

Page 18 © Siemens, 2005


Configuration
PCMB, BTSM and Mapping Timeslot in Abis Interface

Page 19 © Siemens, 2005


Commissioning Flow
Download Software

Dalam 1 COBA bisa menampung 3 Software BTSE yang berbeda

Page 20 © Siemens, 2005


Commissioning Flow
Activate Software

Page 21 © Siemens, 2005


Commissioning Flow
Set Rack

Page 22 © Siemens, 2005


Commissioning Flow
Create RACK3/ Service RACK

Full Configuration 24 TRX = 3 Rack (1 Base Rack + 2 Extention Rack)


Service Rack selalu Rack3/untuk bodetabek SR 4 & 5

Page 23 © Siemens, 2005


Commissioning Flow
Set COBA

Jika dalam Base Rack terdapat FCU maka COBA perlu di set TRUE
TRUE = support of FCU enable
FALSE = support of FCU disable

Page 24 © Siemens, 2005


Commissioning Flow
Create FCUMAIN

FCUMODE ada 2 : Single mode / Double Mode


Singe Mode = does not two of TRX Instances
Double Mode = support of two TRX Instances (TX Time Shift Diversity)

Page 25 © Siemens, 2005


Commissioning Flow
Create FCUTR

Page 26 © Siemens, 2005


Commissioning Flow
Create DUVSWR

Page 27 © Siemens, 2005


Commissioning Flow
Set DULNA

Page 28 © Siemens, 2005


Commissioning Flow
Create FANP

RACK0/Base Rack

RACK3/ Service Rack

Page 29 © Siemens, 2005


Commissioning Flow
Create ACT

Pin ACT PIN 1 2 3 4


Open
Close

Page 30 © Siemens, 2005


Commissioning Flow
Create ENVABTSE

Standard Alarm HCPT


ENVA 2 : #ACDC_FAULT
ENVA 3 :BATERY BREAKDOWN
ENVA 4 :BATERY CHARGER FAULT
ENVA 5 :DC VOLT OUT OF TOLERANCE

Page 31 © Siemens, 2005


Commissioning Flow
Create BPORT

Page 32 © Siemens, 2005


Commissioning Flow
Create LAPDLE

Page 33 © Siemens, 2005


Commissioning Flow
Set BTSEP

Page 34 © Siemens, 2005


Commissioning Flow
Set BTSM

Page 35 © Siemens, 2005


Commissioning Flow
Switch phase 2 to 3/ connect BSC

Page 36 © Siemens, 2005


Commissioning Flow
Unlock TRX (Remote from BSC)

Page 37 © Siemens, 2005


Commissioning Flow
Unlock Channel (Remote from BSC)

Page 38 © Siemens, 2005


Commissioning Flow
Unlock TRX (Remote from BSC)

Page 39 © Siemens, 2005


Commissioning Flow
Unlock BTS (Remote from BSC)

Page 40 © Siemens, 2005


Commissioning Flow
Unlock PTPPKF (Remote from BSC)

Only for BTS that support GPRS

Page 41 © Siemens, 2005


Data Inventory

1
Inventory data on Rack
Available ?

no yes

2 Upload REMINV

Open file taken from (1), ex :


OMP_S5001458_NE374RM2407.IDF

Manual list
3 Export NOB -> save file
Create Nob RIUs file for DL? -> No

4 Open file taken from (2)


File -> attach from (3)
Save as …… IDT

Export NOB -> save file


Create Nob RIUs file for DL? -> Yes

Upload REMINV

Inventory using Excel finish

Page 42 © Siemens, 2005


Data Inventory
Document Holder

BS-240

BS-240 II

Page 43 © Siemens, 2005


Data Inventory
Upload REMINV

Page 44 © Siemens, 2005


Data Inventory
Download REMINV

Page 45 © Siemens, 2005