Recycling of Circuit Breaker

Stop the Loco, secure the control stand

TH IDLE REVERSOR NEUTRAL ER, GF SWITCH OFF (DOWN) ISLOATION SWITCH - ISOLATE
2. Switch off the Computer Control Breaker.

COMPUTER CONTROL (OFF)


3. Switch off the Affected Circuit Breaker

MAB (OFF)
Wait for 30 Seconds
Switch on the Affected Circuit Breaker

MAB (ON)
Switch on the Computer Control Breaker Last

COMPUTER
CONTROL - (ON)
EM-2000 will display:-

Air Brake Penalty, Keep Handle in FS for 10


Seconds.

Move Auto Brake Handle to FS


After 10 Seconds, When EM-2000 Displays:-

To Restore Normal Air Brake Operation Place


Automatic Handle in Running.

Move the Auto Brake Handle to RUN.


ALWAYS WHILE RECYCLING TCC BREAKER, RECYCLE THE
FOLLOWING BREAKERS.

S.N GTO LOCOS IGBT LOCOS


1 COMPUTER BREAKER COMPUTER BREAKER
2 TCC-1
TCC BREAKER
3 TCC-2

4 AC GTO PS-1 IGBT-1 BREAKER

5 AC GTO PS-2 IGBT-2 BREAKER

You might also like