Bldg. Laws - BP 344

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 34

Batas Pambansa Blg.

344

“AN ACT TO ENHANCE THE MOBILITY OF


DISABLED PERSONS BY REQUIRING CERTAIN
BUILDINGS; INSTITUTIONS,
ESTABLISHMENTS, AND PUBLIC UTILITIES TO
INSTALL FACILITIES AND OTHER DEVICES”

Approved: February 25, 1983


RULE V - ADMINISTRATION AND ENFORCEMENT

■ WHEELCHAIR
– 1.10~1.30m Length of Wheelchair
– 0.60~0.75m Width of Wheelchair
– 1.50m Circular Clearance
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ COMFORTABLE REACH OF PERSON IN WHEELCHAIR
– 0.70~1.20m Above the Floor &;
– not less than 0.40m from Room Corners
– Comfortable Clearance for Knee & Leg spaces under table is
0.74m
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ WHEELCHAIR SEATING SPACE

Seating Capacity Wheelchair Seating Capacity

4~50 2
BP 344| The Law to Enhance Mobility of Disabled Persons

51~300 4
301~500 6

*When exceeds 500, provide add. 1 wheelchair seat space for every add. 100 seats.
RULE V - ADMINISTRATION AND ENFORCEMENT
■ DROPPED CURBS
– 1:12  Ramped toward adjoining Curb
– Lowest Point of Dropped Curb not exceeding 25mm
– Sloped toward the Road:  max.: 1:20
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ DROPPED CURBS
– 1:12  Ramped toward adjoining Curb
– Lowest Point of Dropped Curb not exceeding 25mm
– Sloped toward the Road:  max.: 1:20
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ DROPPED CURBS
– 1:12  Ramped toward adjoining Curb
– Lowest Point of Dropped Curb not exceeding 25mm
– Sloped toward the Road:  max.: 1:20
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ CURB CUT-OUTS
– 0.90m  Min. Width (Same w/ Dropped Curb)
– 1:12  Gradient Ramped toward adjoining Curb
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ CURB CUT-OUTS
– 0.90m  Min. Width (Same w/ Dropped Curb)
– 1:12  Gradient Ramped toward adjoining Curb
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ WALKWAYS & PASSAGEWAYS
– Gradient no more than 5% or 1:20
– Max. Cross Gradient of 1:100
PD 1096
BP 344| The Law to Enhance Mobility of Disabled Persons

B.P. 344
5% or 1:20

Cross
Gradient:
1:100
RULE V - ADMINISTRATION AND ENFORCEMENT
■ WALKWAYS
– Min. Dimensions 1.20m wide
– Turn Around min. Dimensions of 1:50m x 1.50m
– Turn Around max. distance of 12.00m between stops
Walkway Headroom  not less than 2.00m in Ht.
BP 344| The Law to Enhance Mobility of Disabled Persons


RULE V - ADMINISTRATION AND ENFORCEMENT
■ PEDESTRIAN CROSSING
 Perpendicular as Possible to Carriageway
 Be located at Narrowest, most convenient part of
Carriageway
 If width of Carriageway exceeds 10.00m
BP 344| The Law to Enhance Mobility of Disabled Persons

 provide Central Refuge of at least 1.50m in depth.


 Preferably/Ideal is at 2.00m in depth
RULE V - ADMINISTRATION AND ENFORCEMENT
■ PEDESTRIAN CROSSING
 Provide “TACTILE BLOCKS in immediate vicinity of Crossing
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ PEDESTRIAN CROSSING
SUFFICIENT TIME
 Min. Crossing Period  6 Seconds
 Walking Speed: 0.90m per Second
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ GRATING OPENINGS
– Openings should have max.
dimensions of 13mm x 13mm
– Shall not project more than
6.50mm above level
BP 344| The Law to Enhance Mobility of Disabled Persons

■ ELEVATOR
– Min. width of opening  800mm
– Elevator Car min. dimension
 1.10m x 1.40m

30.00m Max. Distance


RULE V - ADMINISTRATION AND ENFORCEMENT
■ ELEVATOR
 Control Panels & Emergency System of Accessible Elevators,
Centerline Ht. for Topmost Buttons shall between 
0.90~1.20m from Floor.
 Button Control & Elevator Door Frame shall have
Braille Sign
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ HANDRAILS
– Installed at 0.70 & 0.90m above Steps or Ramp
– With Long Extension of 0.30m above level
– Required full grip should have Dimensions of
0.30~0.50m
BP 344| The Law to Enhance Mobility of Disabled Persons

760-865mm
800-900mm
700-900mm

Accessibility Law (BP 344) NAT’L BLDG. CODE (PD 1096) NEW FIRE CODE (RA 9514)
RULE V - ADMINISTRATION AND ENFORCEMENT
■ HANDRAILS
 If Attached on Walls  If Attached on Ledges
 50mm Clearance from Wall  40mm Clearance from Ledge
BP 344| The Law to Enhance Mobility of Disabled Persons

 If for Great Height  Suggested Design


 1.00~1.06m
RULE V - ADMINISTRATION AND ENFORCEMENT
■ PARKING AREAS
 Accessible Parking Slots min. width  3.70m
 Walkway for Accessible Spaces  1.20m wide
 Provide Dropped Curbs or Curb Cut-outs to Parking
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ ENTRANCES
 One Entrance Level provided where Elevators are Accessible
 Entrances with Vestibule  1.80m in Depth
 1.50m in Width
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ DOORS
 Min. Clear Width of 0.80m
 Should be Operable by Pressure not more than 4.0 kg.
 Doorknobs located between 0.82-1.06m above Floor
 Vertical Pull Handles  1.06m Center above Floor
BP 344| The Law to Enhance Mobility of Disabled Persons

 Major Circulation Routes w/ Kick Plates at Ht. of 0.30~0.40m

800mm

Note:  710-1220mm Min width on RA 9514


 900mm Min. Width of Doorway ON PD 1096
RULE V - ADMINISTRATION AND ENFORCEMENT
■ DOORS
 Min Clear Level Space of  If Door Open but not into
1.50 x 1.50m if open Corridor  maintain Corridor
into Corridor width 1.20m (min.)
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ THRESHOLDS ■ SWITCHES
 Max. Ht. of 25mm &  Positioned
preferably Ramp. 0.92~1.20m Ht.
 Located no further than
0.20m from Latch Side
BP 344| The Law to Enhance Mobility of Disabled Persons

 13mm max. Ht. on


25

RA 9514 (Fire Code)


RULE V - ADMINISTRATION AND ENFORCEMENT
■ WASHROOM & TOILETS
 Min. Area of 1.70 x 1.80m & preferably Ramp.
 Installed 1 movable Grab Bar & 1 Faced to adjacent wall
 A Turning Space of 2.25sq.m. with Min. Dimension
of 1.50 x 1.50m shall be provided
BP 344| The Law to Enhance Mobility of Disabled Persons

■ MIN. NUMBER OF ACCESSIBLE


WATER CLOSETS PER FLOOR
 20 Male & 20 Female
 Provide 1 PWD Toilet
 20+ Male & 20+ Female
 Provide 2 PWD Toilet
RULE V - ADMINISTRATION AND ENFORCEMENT
■ URINAL & LAVATORY
 LAVATORIES  Max. Ht. of 0.80m w/ knee recess
of 0.60-0.70m ht. and 0.50m depth.
 URINALS  may be Elongated Lip or Trough-Type
BP 344| The Law to Enhance Mobility of Disabled Persons

0.48m Max. Ht. of Lip


RULE V - ADMINISTRATION AND ENFORCEMENT
■ WATER CLOSET
 Max. Ht. of seat is
0.45m
 Flush Control Ht. of
1.20m Max.
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ SIGNAGES
 Max. Ht. of 1.60m and Min. Ht. of 1.40m
 Raised Symbols with Min. Ht. of 1mm
 Text on Signboards can read at Certain Distance
[Height of Text (cm)] = [max. Reading Distance (m)]
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ STAIRS
 Should be Slip-Resistant Material
 Nosing should be provided w/ slip-Resistant Strips
 Tactile Strips 0.30m standard wide shall installed before Hazardous
Areas such sudden changes in Floor Levels & at Top & Bottom of Stairs.
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ FIRE EXIT STAIRS
 Must Have Area of Refuge  1.20 x 0.85m in
dimension
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ RAMPS
 Ramps shall have a minimum clear width of 1.20 m
 The maximum gradient shall be 1:12
 The length of a ramp should not exceed 6:00 m. if the gradient is 1:12;
longer ramps whose gradient is 1:12 shall be provided with landings not
less than 1.50 m.
BP 344| The Law to Enhance Mobility of Disabled Persons

 A level area not less than 1.80 m. should be provided at the top and
bottom of ramp
RULE V - ADMINISTRATION AND ENFORCEMENT
■ WATER FOUNTAINS
 At least (1) for every 2,000sq.m.
 Shall be at the front & Push-Button Controlled
 If wall Mounted, Max. Ht. must be 0.85m (from Floor to Rim)
BP 344| The Law to Enhance Mobility of Disabled Persons

■ COUNTERS
 Provide area for PWD  0.80x1.30m
 Ht. of counter  range 730~780mm
RULE V - ADMINISTRATION AND ENFORCEMENT
■ PLACES OF ASSEMBLY
 Wheelchair Space  0.60m wide (min.) & near Aisle
 Center of Wheelchair Space from seat in back:
0.45m (min.)~0.60m (preferred)
BP 344| The Law to Enhance Mobility of Disabled Persons
RULE V - ADMINISTRATION AND ENFORCEMENT
■ SAFETY FENCE
 All Excavations, must be adequately protected of Fenced-in to
protect Pedestrians.
 Ht. of Rail should be at least 1.00m
 Incorporate “TAPPING RAIL” of 0.35m
BP 344| The Law to Enhance Mobility of Disabled Persons
TERMINOLOGIES
■ ALCOVE  Small recessed space in Room or Floor
■ ANTHROPOMETRIC  measurement of Human Body
■ EGRESS  Exit, means going out

BP 344| The Law to Enhance Mobility of Disabled Persons

THRESHOLD  Strip fastened to Floor beneath a Door


■ VESTIBULE  Small Entranceway or Transitional Space from
Exterior to Interior
■ WASHROOM  Facilities for Washing
 Consist of Lavatory & Toilet Room
■ WATER FOUNTAIN  Consist of Shallow basin, w/ water Jet to
provide Portable Water for Human Consumption
■ FULL BATH  Lavatory + Water Closet + Bath tub
■ HALF BATH  Lavatory + Water Closet + Shower
■ QUARTER BATH  Lavatory + Water Closet only