Professional Documents
Culture Documents
19A 5G Site Design Solution
19A 5G Site Design Solution
BBU5900
BBU5900 Power Module
BBU5900 Fan Module
Determined based on the site Note 2: The heat dissipation capability depends on the fan.
conditions.
B. Composition
D. Technical specifications
N/A
Port Introduction
UPEUe Introduction (English)
Panel Identifier Connector Type Quantity Remarks
C. Configuration Principles EXT-ALM0 RJ45 connector 1 Port for Boolean signal inputs 0 to 3.
The BBU5900 is delivered with one UPEUe by default. EXT-ALM1 RJ45 connector 1 Port for Boolean signal inputs 4 to 7.
If the power consumption of the service boards in the BBU is greater
MON0 RJ45 connector 1 Port for RS485 signal input 0.
than 1100 W (excluding the fan module), add one UPEUe.
If the power consumption of the service boards is less than 1100 W MON1 RJ45 connector 1 Port for RS485 signal input 1.
(excluding the fan module) and the capacitor redundancy feature is
required, add one UPEUe.
One UPEUe supports 1~8 dry contact alarms.
If 9~16 dry contact alarms need to be reported, manually configure
one more UEIUb.
B. Composition
One branch power cable
C. Configuration Principles
(1)
(1) HDEPC
HDEPC connector
connector
Quantity: Determined based on the number of BBU (2)
(2) EPC4 connector
EPC4 connector
power modules.
One UPEUe is configured with one power cable.
Two UPEUes are configured with two power cables. (1) EPC4 connector
(1) HDEPC
Length: Maximum 20 m. It is recommended that the (2) Scale line
connector
(3) Sliders
(2) Slider
length be within 6 m. (4) Hole for the
(3) Terminal
conductor
D. Technical Specifications
BBU5900 Power Cable Introduction (English) HDEPC Installation Guide (English) EPC4 Installation Guide (English)
A. Purpose E. Appearance
The FANf module performs the following functions:
• Dissipates heat for other boards in the BBU.
• Controls the speed of fans, monitors the temperature of fans, and
reports the status, temperature, and in-position signals of fans.
• Provides a read/write electronic label.
C. Configuration Principle
The BBU5900 is delivered with one FANf by default.
A. Purpose
Provides 10 DC power outputs. DC input terminals NEG(-) Two M6 one-hole OT terminals.
RTN(+) Maximum:
The output voltage is equal to
• One pair of 35 mm 2 cables.
the input voltage. • Two pairs of 25 mm 2 cables.
DC output terminal LOAD0 ~ Uses EPC5 connector. Single through-current
B. Composition LOAD5 Supports cables with the cross- capability is 30 A
DCDU12B case sectional area of 3.3 mm to 10 mm . (derated). 25 A is used.
2 2
E. Appearance
B. Composition E. Appearance
Up converter case (EPU02D-02)
Two up converters (BDU65-03)
One management module (PMU12A)
One monitoring cable (included)
C. Configuration Principles
Length of the input power cable: 12 m by default.
(1) EPU02D series subrack
Types of ground cables: Determined based on the region. (2) BDU65-03
Length of the ground cable: 2 m by default. (3) PMU 12 A
UPEU
UPEU
UPEU
UPEU
Important notes: The external frames of EPU02D and EPU02D-02 are the same, but the two sets of equipment are different. For details, see
http://support.huawei.com.
HUAWEI TECHNOLOGIES CO., LTD. Huawei confidential. Page 15
EPU02D-02 Monitoring Signal Cable
E. Appearance
A. Purpose
Reports the environment variables and alarm parameters of
the EPU02D-02 to the BBU5900 power module (UPEUe).
The environment variables of the EPU02D-02 are output by (1) RJ45 connector
the COM port of the PMU12A. X1 End X2 End Wire Type
The PMU12A alarm uses the RS485 serial port protocol. X1.1 X2.1
Twisted pair
X1.2 X2.2
X1.3 X2.3
Twisted pair
B. Composition X1.6 X2.6
90%
D. Technical Specifications
UMPTe1: Not includes satellite card. (In the initial phase of the NR, the TDD system is used, requiring
time synchronization. The main control board that does not contain the satellite card is not
UMPTe type recommended.)
UMPTe2: Delivered outside China (including the GPS satellite card).
UMPTe3: Delivered in China (including BeiDou/GPS dual-mode satellite card).
Transmission interfaces 2 x FE/GE (electrical interface, RJ45), 2 x FE/GE/10GE (optical interface, SFP)
Transmission bandwidth (DL+UL) 10 Gbps
RAT G/U/L/NB-IoT/NR
Three QSAs are inserted into three QSFP cages of the UBBPfw1 and UBBPfw2. Six SFP cages are displayed
on the board.
oo n
ng s
m i
Co
High-frequency Low-frequency
coverage, for example, coverage, for For details, please refer to
3.5 GHz frequency example, 1.8 GHz
band frequency band this technical document. 5G Uplink and
Cell radius Downlink Decoupling
HEI interface
HEI interface
In co-subrack scenarios, the CPRI MUX connection mode is In inter-subrack scenarios, the CPRI MUX connection mode is preferred.
preferred. The CPRI MUX solution has one CPRI optical cable less than the dual-star solution.
The CPRI MUX solution has one CPRI optical cable less than
Baseband processing board--LTE: UBBPd/UBBPe; NR: UBBPfw1
the dual-star solution.
Control Board--LTE: UMPT; NR: UMPTe (5G RAN2.0 supports L & NR in one UMPTe).
UMPTx(L) CI
UMPTe(N) Add a group of optical modules and optical cables between the RRU and the BBU.
The types of optical modules and types of optical cables are the same as those of existing LTE.
UBBPd/e
• The main control board in the LTE subrack must be connected to the CI port
of the main control board of the NR subrack.
UMPTx(L) CI
UMPTe(N) The following slide focus on the red interconnection solution.
E. Appearance
B. Composition
One QSFP port cable main body
C. Configuration Principles
Quantity: One cable is configured between two UBBPs.
Length: 10 m, 30 m, or 100 m. For any other (1) MPO connector
(2) Strap
requirements, submit an RM workflow. (3) MPO connector
Note: The optical module interconnection of HEI port is different from that
of the CI port. Color rings need to be distinguished for CI, but not for HEI.
Electrical port backhaul solution: The Ethernet cable solution is used, supporting only GE.
Optical port backhaul solution: The optical module and optical cable solution (mainly introduced) are used, supporting 10GE.
C. Configuration Principles
Quantity: One for each UMPT
One user transmission backup feature can be configured.
C. Configuration Principles
Quantity:
(1) DLC connector
If one optical module is required in the transmission solution,
(2) Branch optical cable
configure one optical cable.
(3) Branch optical cable label
If two optical modules are required in the transmission
(4) FC connector
solution, configure two optical cables.
(5) LC connector
Length:
(6) SC connector
Determined based on the site survey. 10 m, 20 m, and 30 m
are provided.
Port type:
Determined based on the ODF. FC, LC, and SC are provided.
AAU5613
AAU5313
AAU5310
RRU5258
HAAU5213
d
Maximum operating windata 150 km/h
• One for one sector. speed
All
Rated wind velocity 200 km/h
*: To achieve the claimed effectiveness, the
Relative humidity 5% RH to 100% RH
following four conditions should be met: 25°C,
50% load, 3:1 uplink/downlink configuration, and Ingress protection rating IP65
batch 70% modules configured.
d
Operating temperatureata -40 ºC to +55 ºC (without solar radiation)
ll
C. Configuration Principle Wind resistanceA Front: 260 N (at 150 km/h)
Side: 75 N (at 150 km/h)
• One for one sector. Back: 260 N (at 150 km/h)
SFP connector
SFP connector
SFP optical module (10
Gbit/s or 25 G bit/s)
SFP optical module (10
Gbit/s or 25 G bit/s) QSA adapter
UBBPfw1 UBBPfw1
A. Purpose
Connects the BBU baseband
D. Main Parameters
processing board and RRU/AAU. E. Appearance
Item Specifications
Type Single-mode Single-mode Multi-mode
B. Composition Port Double LC Double LC Double LC
E. Appearance
C. Configuration Principles
Quantity:
If one AAU/RRU is configured with one pair of optical modules, configure one optical
cable.
If one AAU/RRU is configured with two optical modules, configure two optical cables. (1) Double LC connector
Length: (2) Branch optical cable
Determined based on the site survey. 10 types of cables ranging from 10 m to 100 m (3) Branch optical cable
are provided.
C. Configuration Principles
(1) DLC connector
Quantity:
(2) Branch optical
If one AAU/RRU is configured with one pair of optical modules, configure cable
one optical cable. (3) Branch optical
If one AAU/RRU is configured with two optical modules, configure two cable label
optical cables. (4) FC connector
Length: (5) LC connector
Determined based on the site survey. 10 m, 20 m, and 30 m are provided. (6) SC connector
Port type:
Determined based on the customer's ODF. FC, LC, and SC are provided.
E. Appearance
B. Composition
Optical cable body.
Wavelength division multiplexing (WDM): Transmit multiple optical waves with different wavelengths synchronously in a single fiber.
It makes full use of the large bandwidth resources in the low loss area of the single-mode optical fiber. Using the multiplexer, it combines the optical waves of
different wavelengths at the transmit end, and then transmits the signals to the single-mode optical fiber. In the receiving part, the demultiplexer adopts the
multiplexing method of separating the optical waves of different wavelengths. Because the optical waves of different wavelengths are independent of each
other, the bidirectional transmission can be solved.
Different number of wavelengths can be multiplexed using different wavelength division multiplexers (demultiplexers or multiplexers).
According to the different channel spacing, WDM can be classified into Coarse Wavelength Division Multiplexing (CWDM) and Dense Wavelength Division
Multiplexing (DWDM).
Appendix: MO Introduction
Huawei Wireless Product Line released the DWDM passive WDM solution for wireless fronthaul from 19AC9x. ��ԴDWDM����ǰ��
������f5G��վE2E���
��ٲ
9X
25 192.50 1557.36
56 195.60 1532.68 40 194.00 1545.32 24 192.40 1558.17
C
55 195.50 1533.47 39 193.90 1546.12 23 192.30 1558.98
a f t 9
54 195.40
A
1534.25 38 193.80 1546.92 22 192.20 1559.79
Dr d in 1
53 195.30 1535.04 37 193.70 1547.72 21 192.10 1560.61
52 195.20 1535.82 36 193.60 1548.51 20 192.00 1561.42
51 195.10 1536.61 35 193.50 1549.32 19 191.90 1562.23
a s e 50
49
195.00
194.90
1537.40
1538.19
34
33
193.40
193.30
1550.12
1550.92
18
17
191.80
191.70
1563.05
1563.86
e r 47
46
194.70
194.60
1539.77
1540.56
31 193.10 1552.52 15 191.50 1565.50
b
30 193.00 1553.33 14 191.40 1566.31
To
45 194.50 1541.35 29 192.90 1554.13 13 191.30 1567.13
34061920 34061921
Optical modules must be used in pairs.
9 X
f t A C
ra 1 9
210 mm (W) * 290D d in
mm (H) * 60 mm (D)
a s e Optical cable description
e l e
e r
b
To
Pole mounting kits
The diameter of the optical cable is 7 mm.
The pigtail length of the optical cable is 30 mm.
Note: Supports 14 optical fibers. Twelve optical fibers support twelve RRUs, one is a convergence optical fiber, and one is reserved.
9 X
ft A C
r a 1 9
D d in Four types of mounting bracket and four types of outdoor
e
wavelength flange.
el
No. Name Quantity Material For example: Support the interconnection with the 25# to 60#
1 Mounting bracket 1
r
1.5 mm galvanized steel plate + powder
e
optical modules.
2 2LC/PC adapter 12
b
Huawei BOM number: 14130249
To
3 LC/PC adapter 2 Huawei BOM number: 14300121
Note: The 12-wavelength and 24-wavelength mounting brackets differ only in
the number of flanges.
Ultimate planning: Outdoor multiplexer and demultiplexer have six BOM numbers.
Support
Support
Two 24-wavelength boards + two 12-wavelength boards
Six 12-wavelength boards
One 48-wavelength board + two 12-wavelength boards
9 X
f t A C
ra 1 9
D d in
a s e
e l e
e r
b
Height: 1 U To
Width: 19 inch Width: 19 inch
Height: 1 U
9 X
f t A C
ra 1 9
24-wavelength board has two plans.
D d in
as e
el e
e r
b
To
48-wavelength board has one plan.
9 X
ft A C
r a 1 9
D d in
a s e
e l e
e r
b
To
Core point:
E. Appearance
B. Composition
Up converter case (included)
Two up converters (included)
One management module (included)
One monitoring cable (included)
Input power cable of the up converter (configuration and site survey are required)
Ground cable of the up converter (configuration and site survey are required)
C. Configuration Principles
Each case supports two up converters and a maximum of four AAUs/RRUs.
Types of input power cables: Determined based on the region.
Length of the input power cable: The default value is 12 m, which can be manually changed. (1) EPU02D series subrack
Types of ground cables: Determined based on the region. (2) BDU65-03
(3) PMU 12A
Length of the ground cable: The default value is 2 m.
DCDU-12B BBU5900
RF module
DCDU input
BBU power cable
Customer DC RF module
power ground
distribution box cable
RF module power cable
RF module
Monitoring cable
COM_IN MON0
EPU02D-02 BBU5900
DCDU input
BBU power cable RRU5258
ground
cable
Customer DC
power
distribution box RRU power cable
DCDU-12B BBU5900
DCDU input
BBU power cable
RF
module
ground
cable
Customer DC
power
distribution box
RF module power cable
0 , 20
APU BBU5900
b e r3
N o ve m
fr o m
BBU power
d ed RF
DCDU input cable
v i module
pro
power cable ground
b e cable
Customer DC
is to
power
tio n
distribution box
s o l u RF module
P U power cable
h e A
T
AAU5310 is mainly delivered to Korea, where the Centralize RAN scenario is used.
The power supply solution of the AAU5310 must be adopted in the outdoor. Blade power supplies and blade
batteries are recommended.
Blade power supply and blade battery in the wireless configurator are OPM30 VB and TBD.
Blade power supply and blade battery in the energy configurator are DPU40D and DBU40B.
In some scenarios, the AAU power supply distance is long. When the existing DCDU-12B, EPU02D-02, or APU
does not meet the requirements, AC power supply is recommended. The power supply and battery of the AC
blade are deployed under the tower.
48 V DC
220 V AC
AAU/RRU
Channel
Source modulate filter coupling
coding
Power
BBU line
PLC
eCPRI/CPRI Channel
Sink demodulate filter coupling
decoding
CPRI/eCPRI
Results:
3. The MEB alarm cable needs to be
added.
4. The MEB supports six dry contact
alarms.
Dry contact
alarm cable
EMS
To third-party
power supply To MEB
Item Specification
Dimensions (H x W x D) 240 mm x 86 mm x 60 mm
Weight 1.3 kg (2.87 lb)
Input power -48 V DC;
voltage range: -36 V DC to -57 V DC
Rated current 40 A
Power consumption 5W
Ambient temperature (long-term • With solar radiation of 1120 W/m ²: -40 ℃ to +50 ℃
operation) • Without solar radiation: -40 ℃ to +55 ℃
Relative humidity 5% RH to 95% RH
Ingress protection (IP) rating IP65
Neighboring eNB D D S U D D Impacts and requirements of NR (TDD) base station clock source faults:
Interference
Downlink interferes uplink between base stations -> Inter-base station out-of-synchronization
Faulty eNB D D S U D D tolerance time
Downlink interferes uplink between UEs -> Inter-UE guard interval
Downlink to uplink: Gap~70us; Uplink to downlink: T BS off on 17us Between base stations: 3us; Absolute precision: Basic
LTE(TDD) -
±1.5us service
The clock synchronization specifications of 5G NR (TDD) are basically the same as those of LTE
TDD: ±1.5us