Professional Documents
Culture Documents
SMART UNO/Refarm RET Cabling & Naming Convention: (Needs Site Testing and Verification Before Taken in Use!)
SMART UNO/Refarm RET Cabling & Naming Convention: (Needs Site Testing and Verification Before Taken in Use!)
SMART UNO/Refarm RET Cabling & Naming Convention: (Needs Site Testing and Verification Before Taken in Use!)
R2V2PX310R R2V2PX310R
ANT 1 ANT 2
ANT 1 ANT 2
Smart RET
OUT
BiasT
RET
Control RET
RET Cable 0.5m Control
Control Cable 0.5m
Cable RET
0.5m Control
Cable
3m
FEEDER
FRGT
4 © Nokia Solutions and Networks 2016
U2100 RF VIEW FROM BEHIND OF ANTENNA
Customer Confidental
TX1
ANTENNA NUMBER FROM RIGHT TO LEFT
ANTENNA 1
R2V2PX310R
ANT 1 ANT 2
8-port Antenna
G1800 / U2100 G1800 / L2100
R2V2PX310R
HB HB HB HB
RET 1-2 RET 2-2
RET
U2100
Control
RET Cable 0.5m
Control
Cable
RET 0.5m
Control
Cable 0.5m FEEDER
RET FRGT
Control U2100 RF
Cable TX1
3m
1x8-port Antenna 1x8-port Antenna
With RET Cable from RFM With Smart BiasT and Feeder
5 © Nokia Solutions and Networks 2016
Customer Confidental VIEW FROM BEHIND OF ANTENNA
ANTENNA NUMBER FROM RIGHT TO LEFT
ANTENNA 2 ANTENNA 1
R2V2PX310R
4-port Antenna
8-port Antenna ANT 1 ANT 2
80010622V01
R2V2PX310R
4-port Antenna
U2100 L2100
HB HB HB HB
ANT 1 ANT 2 80010622V01
RET 1-2 RET 2-2
RET HB
RET 1-2
HB HB
RET 2-2
HB
+45 +45
1-1
-45 -45 +45 +45
2-1
-45 -45
RET
Y2
Y2
+45
Y2
-45
Y1 Y1
-45 +45
RET
Y1
FRGT G1800
3 1
IN OUT
2 4 3 1
IN OUT
2 4 3 4 2 1
RET RET
RET RET
RET RET
RET IN OUT
IN OUT
MOT
OR
MOT
OR
Control
RET RET
RET RET
Cable 0.5m RET
IN OUT
IN OUT
RET Control
Control Cable
RET RET
Control Cable 0.5m 0.5m
Control
Cable 0.5m Cable
0.5m RET
RET RET Control
Control Control Cable 3m
FEEDER
Cable Cable
3m 3m
FRGT
1x4-port + 1x8-port Antenna U2100 RF
TX1
RET RET
IN OUT
RET
RET
RET MOT
RET
MOT FRGT 0.5m
MOT OR OR
OR U2100
RET RET
RET
IN
RET
OUT RET
IN
RET
OUT
RET
IN OUT
Control
RET Cable
Control 3m RET
Cable Control
3m RET Cable 0.5m
Control
Cable 0.5m RET
Control FRGT FEEDER
Cable U2100 RF
3m TX1
1x4-port + 1x2-port Antenna
1x4-port + 1x2-port Antenna
With RET Cable from RFM
7 © Nokia Solutions and Networks 2016
With Smart BiasT and Feeder
Customer Confidental VIEW FROM BEHIND OF ANTENNA
ANTENNA NUMBER FROM RIGHT TO LEFT
RET Naming Convention
3. Sector ID
1 character {A-Z} 5. RET Location ID
Sec 1 – A 2 characters {0-9, A-Z}
Sec 2 – B L1, L2, H1 or H2 = R2V2PX310R
Sec 3 – C Y1 or Y2 = 80010622v01
4. Antenna ID L1 = 80010306v02
Sec 4 – D
1 character {1-9}
Which antenna in the sector (1, 2 or 3)
(from behind the antenna, RIGHT to LEFT)
9 © Nokia Solutions and Networks 2016
Customer Confidental
PH SMART RET Name Convention
RET RET
IN OUT
0.5m
RET
Control
Cable
3m RET
Control
Cable 0.5m
FRGT FEEDER
U2100 RF
TX1
3.0 Olli Ruusunen RET cabling drawings changed according to new antenna arrangement. 21/04/2016
Added examples of site RET naming for 2x8-port and 1x4-port +1x2-port antenna