OAQPS Outline of Permit Submittal re: Monitoring Provisions
Background information Monitoring approach description and level of detail Justification and support Basic Background
Emissions unit (PSEU)
Applicable regulations, emission limits, and monitoring requirements Control technology (e.g., control device (CAM), compliance fuel or raw material, process controls, operation and maintenance protocols) Monitoring Approach (CAM)
Measurement method (what and how)
Monitoring frequency and averaging procedures Excursion or exceedance definition (indicator range for CAM) Performance criteria – QA/QC procedures Other Permit Content Factors
Commitment to corrective action
Reporting and recordkeeping Verification of operational status QIP Threshold (optional) Data availability (optional) Table format (for clarity in permit) Justification
Brief description of source/control device
Rationale for selecting indicators Rationale for selecting indicator ranges Supporting information (e.g., test data, design factors, historical data, margin of compliance) Monitoring Approach– Title V Permit Table (example)
Indicator Combustion T Outlet CO conc.
Measurement approach Thermocouple CO CEMS Indicator range Excursion: <1500°F Excursion: >50 ppmv Data representativeness Installed in incinerator PS 4, 40 CFR 60, App. B chamber QA/QC Redundant t-couple and span gas Monitoring frequency Measure continuously Daily zero (+ 30F) Measure continuously (10 sec) Data collection Record continuously Record 1-min averages procedures on chart recorder by DAS (electronic) Averaging period None 1-hr average QIP threshold No more than six No more than 10 7 excursions excursions Questions? Let’s divide into groups