Full IP Network Design Project Plan V1 0

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 11

Airtel GSM Network IP Conversion

HUAWEI TECHNOLOGIES CO., LTD.


Contents

1 GSM & UMTS network Topology

2 IP Clock Server Network Design

3 Co-Transmission Network Topology

4 Co-Transmission Cable Connections

5 Separate-Transmission Cable Connections

5 Full IP Project Plan

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 2
Airtel Network GSM & UMTS network Topology

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 3
Airtel Network IP Clock Server Network Design
 IP Clock Servers will be deployed at Kadawatha and integrated with RNC01A and RNC1B
CX routers. Reference clock will be extracted from MUX equipment.

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 4
Airtel Network IP Clock Server Network Design
 IP Plan for Clock Servers
Network element Port Port Type IP address Remark
Service_Port_FE/GE-1 RJ 45 10.20.100.14/30 Reserved for future use
Service_Port_FE/GE-2 SFP 10.20.100.2/30 Service Port To be in use
IP Clock Server 1
Service_Port_FE/GE-3 SFP 10.20.100.6/30 Reserved for future use
Primary
Service_Port_FE/GE-4 SFP 10.20.100.10/30 Reserved for future use
O&M Port (DBG/NMS) RJ 45 10.200.163.120 M2000 Subnet
Service_Port_FE/GE-1 RJ 45 10.20.100.30/30 Reserved for future use
Service_Port_FE/GE-2 SFP 10.20.100.18/30 Service Port To be in use
IP Clock Server 2
Service_Port_FE/GE-3 SFP 10.20.100.22/30 Reserved for future use
Secondary
Service_Port_FE/GE-4 SFP 10.20.100.26/30 Reserved for future use
O&M Port (DBG/NMS) RJ 45 10.200.163.121 M2000 Subnet

 The IP transport network should meet the quality of service (QoS) requirements ;
 A single port supports a maximum of 512 Nodes. One Clock server supports 2048 Nodes.
QOS Requirement
Delay ≤ 60 ms
Jitter < 20 ms (one-way)
Packet loss < 1%

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 5
Co-Transmission Network Topology(with IP)

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 6
Separate Transmission Network Topology(with IP)

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 7
Co-Transmission Cable Connections
Connect GTMU FE1 port to WMPT FE1 port using optical cable

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 8
Separate Transmission Cable Connections
Connect GTMU FE0 port to the RTN directly using Ethernet cable

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 9
Full IP Project Plan
As per the plan, 3 BSCs should convert to full IP. SOW are below,

• IPCLK Server installation in Kawadatha, commissioning and integration with CX routers.


• GOUc boards installation, fiber laying and integration with CX.
• CX-X3 V6R8 upgrade and LPU50 installation.
• RTN to CX and BSC to CX fiber laying- Requirements: AMP-48 PCS, Kandy-44 PCS & POL-44 PCS
• Full IP Migration--- There are 21 Rings. Per night, Only one ring cutover will be carried out with KPI confirmation.

P.S: Initially RTN ring will be considered.

Weeks
Descriptions
W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11
Materials Arrive to Port-ETA
Materials Clearance
Materials Delivery
BSC GOUc card Installation & Integration
IP Clock Server Installation & Integration
CX-X3-V3R8 upgrade,LPU50-board Installation & commissioning
Site level fiber cable connection(Inter connection) & IP change @ BTS level
Abis & IuB IP migration BSC16- 8 Rings BSC18-6 Rings BSC11-7 Rings

HISILICON SEMICONDUCTOR
HUAWEI TECHNOLOGIES CO., LTD. Page 10
10
Thank you
www.huawei.com

You might also like