1.MW Product&EMS Training

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 61

MW Product&EMS Training

Zhu Congcong 10222866


MW Technology Support Engineer
2019-5-19
CONTENTS

Part 1 Product Description

Part 2 Installation&Dedugging

Part 3 Configuration

Part 4 Loop&Frequency sweeping


Internal use only▲

Part Product Description


1
NR8250&NR8120D

Eband

© ZTE All rights reserved


3
Internal use only▲

NR8250&NR8120D

N
R
8
2
5
0
 RCU Radio control unit  RPU Radio power unit
 RTU Radio transmission unit  RFAB Fan
 RMU Radio modulation unit  PM Power management

© ZTE All rights reserved


4
Internal use only▲

NR8250&NR8120D

N
R
8
2
5
0  RTUB 8E1&STM1&STM1/4 RTUC 32E1
 RTUNE 4GE OR 2GE 2optical RTUIO 10GE
 RMUF 1IF(XPIC cable) RMUN 2IF(Inner XPIC)
 3 1+1 HSB/SD group slot3&4 slot5&6 slot7&8

© ZTE All rights reserved


5
Internal use only▲

NR8250 IDU Structure Diagram


Board Board Available
Function
type name slots
Core Control
Slot1 Slot5 RCUB/C/C2 Core Control & Clock Unit 1-2
Slot13 Unit
Slot2 Slot6
Slot14 Slot16 RMUC Modem Unit (supports XPIC) 3-8
Slot3 Slot7 Modem Unit
Slot15 Slot4 Slot8 (IF Board)
RMUD/E Modem Unit 3-8

RMUH/F/N Modem Unit (supports XPIC) 3-8

RTUA/B/C Native TDM Traffic Unit 2-8

PM RCU RTU/RMU/RSU
RTUHO/E Native TDM+Ethernet Traffic Unit (Opt./Elec.) 2-8
RCU/RTU/RSU RTU/RMU/RSU RFA
PM RTU/RMU/RSU RTU/RMU/RSU Traffic Unit RTUNO/E Ethernet Traffic Unit (Opt./Elec.) 2-8
RPU RTU/RMU/RSU RTU/RMU/RSU
RTUIO 10GbE Traffic Unit (Opt.) 2-4
RPEA PoE Traffic Unit (Elec.) 3-8
Auxiliary
RSUA Auxiliary Service Traffic Unit 2-8
Service Unit

Power Supply PM3/PM5 IDU Power Supply Modular 10-11


Unit RPUA/C ODU Power Supply Unit 12
Fan Unit RFAB Intelligent Cooling Unit 9

© ZTE All rights reserved


6
RCUC/RCUC2 Interface – provide the same interfaces Internal use only▲

LED indicator GbE2 interface LMT interface USB interface RST button

LED indicator GbE/1NMS interface GbE3 interface CLK/MON interface M/S button LED indicator

Name Interface Feature


GbE RJ-45 Gigabit Ethernet service interface, 1000BaseT (Rate: 10/100/1000 Mbps)
NMS RJ-45 Network management interface, 1000BaseT (Rate: 10/100/1000 Mbps)
LMT RJ-45 Local management and debugging interface , 100BaseTx (Rate: 10/100 Mbps)

Clock & Monitor multiplex interface, support clock input or output, supports 2MHz/2Mbps BITS clock and 1PPS+ToD
CLK /MON HDMI
clock; RS485 monitor port, connect with the RS485 port of cabinet

USB USB U disk for fast configuration or USB Wi-Fi access for local management

M/S Button Working status switch: active/standby


© ZTE All rights reserved
7
Internal use only▲

RMUF Interface
LED indicator Power switch IF interface RST button

LED indicator XPIC cross connection interface LED indicator

RMUN Interface

© ZTE All rights reserved


8
Internal use only▲

RTUA/RTUC Interface—Native E1

RTUA

RTUC

Name Interface Feature


RTUA E1 Interface DB68 16*E1, 75 ohms / 120 ohms switchable
RTUC E1 Interface_A (CH1-CH16) D type SCSI 64 16*E1, 75 ohms / 120 ohms switchable
RTUC E1 Interface_B (CH17-CH32) D type SCSI 64 16*E1, 75 ohms / 120 ohms switchable
© ZTE All rights reserved
9
Internal use only▲

RTUB Interface—Native E1 & STM-1/4


Unique STM-1/4
optional interface

Name Interface Feature

8*E1 Interface DB36 75 ohms / 120 ohms switchable


Signal Rate: 155.52 Mbps (ITU-T G.957)
STM-1 Interface S-1.1/L-1.1 (SFP LC)
Channelized/Un-channelized STM-1
STM-4 Interface S-4.1/L-4.1 (SFP LC) Signal Rate: 622.08 Mbps (ITU-T G.957)

© ZTE All rights reserved


10
Internal use only▲

RTUHO/RTUHE Interface—Ethernet & E1

RTUHO

RTUHE

Name Interface Feature


GbE Optical Interface SFP, LC 1000 Base-LX, 1000 Base-SX; Rate: 100/1000 Mbps
GbE Electrical Interface RJ-45 1000 BaseT; Rate: 10/100/1000 Mbps
E1 (CH1-CH8) DB36 8*E1, 75 ohms / 120 ohms switchable

© ZTE All rights reserved


11
Internal use only▲

RTUH1 Interface—Ethernet & E1


GbE (E) interface GbE (O) interface 16*E1 interface

LED indicator

Name Interface Feature


1000 Base-LX, 1000 Base-SX; Rate: 100/1000 Mbps (relates
GbE Optical Interface SFP, LC
to SFP module)
GbE Electrical Interface RJ-45 1000 BaseT; Rate: 10/100/1000 Mbps
E1 (CH1-CH16) DB68 16*E1, 75 ohms / 120 ohms switchable

© ZTE All rights reserved


12
Internal use only▲

RTUNO/RTUNE Interface—Pure Ethernet

RTUHO

RTUHE

Name Interface Feature


1000Base-LX, 1000Base-SX; Rate: 100/1000
GbE Optical Interface SFP, LC
Mbps100/1000 Mbps (relates to SFP module)
GbE Electrical Interface RJ-45 1000BaseT; Rate: 10/100/1000 Mbps
© ZTE All rights reserved
13
Internal use only▲

RTUIO Interface—Pure Ethernet


LED indicator
LED indicator

GbE interface RST button

Name Type Function


10GBASE-SR/LR/ER
GbE Interface Optical SFP+, LC
Rate: 10Gbps

© ZTE All rights reserved


14
Internal use only▲

NR8250&NR8120D

N
R
8
1
2
0
 RTEA 16E1
 4GE+1GE+1/10GE+16E1+2IF
 1+1/1+0/2+0

© ZTE All rights reserved


15
Internal use only▲

NR8250&NR8120D
 1+0/1+1 for end site

 2<=IF<=6

 IF=10

© ZTE All rights reserved


16
Internal use only▲

NR8000 Split-type System Universal ODU - SRU/HRU


SRU: Normal transmit power ODU HRU: High performance ODU

RF in/out
RF in/out
(waveguide type )
(waveguide type )

RSSI IF in/out
RSSI IF in/out

Back view Front view Back view Front view

 Frequency Bands: 6, 7, 8, 10, 11, 13, 15, 18, 23, 26, 28, 32, 38,  Frequency Bands: HRU: 6, 7, 8, 11 GHz
42GHz  Modulation scheme:
 Modulation scheme: HRU V1.3: QPSK~1024 QAM @ BW 7/14/28/40/56 MHz.

SRU V1.3: QPSK~1024QAM @ BW 7/14/28/40/56 MHz HRU V2.0: QPSK~2048 QAM @ BW 7/14/28/40/56 MHz.

SRU V1.4: QPSK~2048 QAM @ BW 7/14/28/40/56 MHz.  SRU/HRU support remote and direct mounting methods

© ZTE All rights reserved


17
Internal use only▲

SRU2 for 15G

© ZTE All rights reserved


18
Internal use only▲

SRU2 for 15G


Installation with mounting bracket

© ZTE All rights reserved


19
Internal use only▲

SRU2 for 15G


Installation with mounting bracket

© ZTE All rights reserved


20
Internal use only▲

Eband

© ZTE All rights reserved


21
Internal use only▲

Installation&Debugging
Part
2 General installation

1+0/1+1/2+0/4+0

Link debugging

© ZTE All rights reserved


22
Internal use only▲

General installation

© ZTE All rights reserved


23
Internal use only▲

1+0/1+1/2+0/4+0
1+1 Because the screw position of ZTE unblanced hybrid is different from reused Andrew
antenna,so we need use integrated adaptor between hybrid and antenna

© ZTE All rights reserved


24
Internal use only▲

1+0/1+1/2+0/4+0
1+1 The default polarization of hybrid is vertical,when the design is horizontal,we need
change it by guide pin
change(check) the polarization of Antenna .If the PQ polarization is H,change the guide
pin on integrated adaptor

Remove these 4
screws,and turn guide
pin 90 degree

© ZTE All rights reserved


25
Internal use only▲

1+0/1+1/2+0/4+0
2+0 We use OMT antenna,dual polarization,the hybrid can support V&H without waveguide
If connected to RMUN(2IF),please use 5-1 for H and 5-2 for V,it’s better for maintenance

H Polarization on the left V Polarization on the right Finish picture

© ZTE All rights reserved


26
Install OMT and ODU(2+0 XPIC)
Internal use only▲

1+0/1+1/2+0/4+0
1+0 We also use OMT antenna for 1+0, Another port on OMT should be blocked by short kit

© ZTE All rights reserved


28
Internal use only▲

1+0/1+1/2+0/4+0
4+0

5-1 : H1 5-2 : V1
6-1 : H2 6-2 : V2
© ZTE All rights reserved
29
Internal use only▲

1+0/1+1/2+0/4+0
4+0

© ZTE All rights reserved


30
Waveguide installation

Waveguide for H&V Loosen the 4 screws and then turn around debugging
Tray installation(4+0 xpic)
ODU combiner and Tray installation(4+0 xpic)

For ODU installation requirements like this, can’t be cross-installed


Combiner installation

For the combiner install we justKeep the default, no need to change


the polarization
ODU installation (4+0 XPIC)

When ODU install finish, all ODU handle is up


Internal use only▲

Link debugging
One direction have one PLA

One frequency have one XPIC

© ZTE All rights reserved


36
Internal use only▲

Link debugging
 Power off 5-2,6-1,6-2 on both site,working as 1+0
 adjust the antenna until the RSL meet the reference value
 Power on 5-2 on both site,working as a 2+0
 Adjust the fixed feeder slowly,let XPI value of both site between 30 to 35
 Power on 6-1/6-2 to check the XPI value and fine adjustment let 8value between 30-35

© ZTE All rights reserved


37
Internal use only▲

Part Configuration
3 System Configuration

Radio Configuration

VLAN&E1 Configuration

© ZTE All rights reserved


38
Internal use only▲

System configuration
Login IDU

Obtain an IP address automacticaly

© ZTE All rights reserved


39
Internal use only▲

System configuration
Login IDU

Run the Internet Explorer.


Enter http://192.168.1.16 as the IP
address of IDU's LMT interface and
press Enter.

© ZTE All rights reserved


40
Internal use only▲

System configuration
Basic parameter1

© ZTE All rights reserved


41
Internal use only▲

System configuration
Base parameter2

10.20.206.8

© ZTE All rights reserved


42
Internal use only▲

System configuration
Basic parameter3

© ZTE All rights reserved


43
Internal use only▲

System configuration
SNMP

© ZTE All rights reserved


44
Internal use only▲

Radio link
Shelf for adding new card

© ZTE All rights reserved


45
Internal use only▲

Radio link
Basic Configuration of radio link

© ZTE All rights reserved


46
Internal use only▲

Radio link
Basic Configuration of radio link
0 QPSK
2 16QAM
3 32QAM
4 64QAM
5 128QAM
6 256QAM
7 512QAM

© ZTE All rights reserved


47
Internal use only▲

Radio link
Basic Configuration of radio link

© ZTE All rights reserved


48
Internal use only▲

Radio link
Basic Configuration of radio link

© ZTE All rights reserved


49
Internal use only▲

VLAN&E1 Configuration
E1 Configuration

 PDH E1->E1 ADM STM1->E1


 VC12 STM1->STM1 E1 cross
 VC4 STM1->STM1 STM1 cross
© ZTE All rights reserved
50
Internal use only▲

VLAN&E1 Configuration
Port Configuration

© ZTE All rights reserved


51
Internal use only▲

VLAN&E1 Configuration
Vlan Configuration

© ZTE All rights reserved


52
Internal use only▲

PLA&XPIC Configuration
PLA&XPIC Configuration

© ZTE All rights reserved


53
Internal use only▲

PLA&XPIC Configuration
PLA&XPIC Configuration

© ZTE All rights reserved


54
Internal use only▲

Part Loop&Frequency sweeping


4 E1 Interface&MU loop

Radio loop

Frequency sweeping

© ZTE All rights reserved


55
Internal use only▲

E1 Interface&MU loop
MU E1 loop

MU loopback is used for check the E1 modem cross, sometimes we cannot confirm H&V
connect to which IF port(maybe one site 5-1 is H but remote site 5-2 is H)
© ZTE All rights reserved
56
Internal use only▲

E1 Interface&MU loop
TDM port loop

Inner loopback:check the upstream E1 route(such as from IDU to BSC)


Outer loopback:check the downstream E1 route(from the E1 board to DDF and other equipment)
© ZTE All rights reserved
57
Internal use only▲

Radio loop

 IF Loopback:check RMU board


 RF Inner Loopback:Check ODU and IF cable
 RF Outer Loopback:check remote site ODU
© ZTE All rights reserved
58
Internal use only▲

Radio loop

 IF Loopback:check RMU board


 RF Inner Loopback:Check ODU and IF cable
 RF Outer Loopback:check remote site ODU
© ZTE All rights reserved
59
Internal use only▲

Frequency sweeping

 Mute remote site and select one IF port


 Select sweep step as bandwith
 Click start and you can get all the interference in ODU sub-band

© ZTE All rights reserved


60
Thank you

You might also like