Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 6

Random Access Example

© Ericsson AB 2010 . Figure - 0 LTE Power Control 2010-06-18


RA Info in SIB 2 Number of preamble codes available

Random Access Open Loop


Power Control Parameters

Maximum number of Random


Access Preamble transmissions

Number of subframes the UE will wait


after sending the Random Access
Preamble waiting for the Random
Access Response

Number of subframes the UE will wait after


sending the Scheduled Transmission (MSG3)
Power of Reference Signals in dBm waiting for the Contention Resolution (MSG4)

Maximum number HARQ


transmissions of the Scheduled
Transmission (MSG3)

ΔPREAMBLE = deltaPreambleMsg3 X 2 = 6 X 2 = 12 dB
TS 36.331
© Ericsson AB 2010 . Figure - 1 LTE Power Control 2010-06-18
Random Access Preamble Power

Path Loss (PL) = referenceSignalPower – Cell RSRP = 15 – (-89) = 104 dB


PREAMBLE_RECEIVED_TARGET_POWER = preambleInitialReceivedTargetPower + ΔPREAMBLE +
(PREAMBLE_TRANSMISSION_COUNTER-1)*powerRampingStep
1st Preamble:
PREAMBLE_RECEIVED_TARGET_POWER = -116 + 12 + (1-1)*2 = -104 dBm
To achieve this target the UE must transmit the 1st preamble at - 104 + PL = - 104 + 104 = 0 dBm

© Ericsson AB 2010 . Figure - 2 LTE Power Control 2010-06-18


PUSCH Power Control Example

© Ericsson AB 2010 . Figure - 3 LTE Power Control 2010-06-18


POPUSCH on SIB 2

© Ericsson AB 2010 . Figure - 4 LTE Power Control 2010-06-18


PUSCH Power

UE TX power reduces with path loss (Cell RSRP increases)

Path Loss (PL) = referenceSignalPower – Cell RSRP = 15 – (-89) = 104 dB

PPUSCH = min {Pmax,10logM + P0PUSCH + α·PL + f(i) + ΔTF} [dBm]


f(i) can be -4, -1, 1 or 4 dB depending on TPC command from eNodeB every 4 subframes

Eg. Above PPUSCH = min { 23, 10log4 -103 + 104 + 1 + 0 } = 8 dBm


© Ericsson AB 2010 . Figure - 5 LTE Power Control 2010-06-18